电流乘法器用于改进脉冲发电机的发电机-负载耦合

A. Chuvatin, L. Rudakov, B. Weber, F. Bayol, R. Cadiergues
{"title":"电流乘法器用于改进脉冲发电机的发电机-负载耦合","authors":"A. Chuvatin, L. Rudakov, B. Weber, F. Bayol, R. Cadiergues","doi":"10.1063/1.1928450","DOIUrl":null,"url":null,"abstract":"Modem pulse-power generators allow obtaining multi - Mega-Ampere currents with sub-microsecond rise-times in useful loads. However, at least during a portion of the rise-time, the load inductance, Ld, can be several times smaller than that of the generator, L0, limiting the energy transfer efficiency. We define a relatively simple circuit modification, which improves the generator-to-load coupling, multiplying the load current in the case of interest, where L0>;>;Ld. The suggested intermediate connection operates similarly to an N:1 transformer. In its simplest configuration, for N=2, the proposed current multiplier requires an additional volume having high self-inductance, L, connected through a single convolute to both generator and load. The modified hardware allows, having possibly one additional unknown, the convolute, and without changing the current rise-time very much an increase of the load current by the factor of Id/I0=2L/(L+Ld), where Io represents the generator current and L can be easily made much greater than Ld. The benefit of the scheme usage is illustrated in simple circuit simulations for two types of potential applications with static, Ld = const, and dynamic, Ld(t), loads.","PeriodicalId":256101,"journal":{"name":"2004 International Conference on High-Power Particle Beams (BEAMS 2004)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Current multiplier to improved generator-to-load coupling for pulse-power generators\",\"authors\":\"A. Chuvatin, L. Rudakov, B. Weber, F. Bayol, R. Cadiergues\",\"doi\":\"10.1063/1.1928450\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Modem pulse-power generators allow obtaining multi - Mega-Ampere currents with sub-microsecond rise-times in useful loads. However, at least during a portion of the rise-time, the load inductance, Ld, can be several times smaller than that of the generator, L0, limiting the energy transfer efficiency. We define a relatively simple circuit modification, which improves the generator-to-load coupling, multiplying the load current in the case of interest, where L0>;>;Ld. The suggested intermediate connection operates similarly to an N:1 transformer. In its simplest configuration, for N=2, the proposed current multiplier requires an additional volume having high self-inductance, L, connected through a single convolute to both generator and load. The modified hardware allows, having possibly one additional unknown, the convolute, and without changing the current rise-time very much an increase of the load current by the factor of Id/I0=2L/(L+Ld), where Io represents the generator current and L can be easily made much greater than Ld. The benefit of the scheme usage is illustrated in simple circuit simulations for two types of potential applications with static, Ld = const, and dynamic, Ld(t), loads.\",\"PeriodicalId\":256101,\"journal\":{\"name\":\"2004 International Conference on High-Power Particle Beams (BEAMS 2004)\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2004 International Conference on High-Power Particle Beams (BEAMS 2004)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/1.1928450\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 International Conference on High-Power Particle Beams (BEAMS 2004)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/1.1928450","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

现代脉冲功率发生器允许在有用负载下以亚微秒的上升时间获得数兆安培电流。然而,至少在一部分上升时间内,负载电感Ld可能比发电机的电感L0小几倍,从而限制了能量传递效率。我们定义了一个相对简单的电路修改,它改善了发电机与负载的耦合,在感兴趣的情况下乘以负载电流,其中L0>;>;Ld。建议的中间连接操作类似于N:1变压器。在其最简单的配置中,当N=2时,所提出的电流倍增器需要一个具有高自感L的附加体积,通过单个卷积连接到发电机和负载。修改后的硬件允许,可能有一个额外的未知,即卷积,并且在不改变电流上升时间的情况下,负载电流以Id/I0=2L/(L+Ld)的系数增加,其中Io表示发电机电流,L可以很容易地比Ld大得多。对于静态(Ld = const)和动态(Ld(t))负载的两种类型的潜在应用,简单的电路模拟说明了该方案使用的好处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Current multiplier to improved generator-to-load coupling for pulse-power generators
Modem pulse-power generators allow obtaining multi - Mega-Ampere currents with sub-microsecond rise-times in useful loads. However, at least during a portion of the rise-time, the load inductance, Ld, can be several times smaller than that of the generator, L0, limiting the energy transfer efficiency. We define a relatively simple circuit modification, which improves the generator-to-load coupling, multiplying the load current in the case of interest, where L0>;>;Ld. The suggested intermediate connection operates similarly to an N:1 transformer. In its simplest configuration, for N=2, the proposed current multiplier requires an additional volume having high self-inductance, L, connected through a single convolute to both generator and load. The modified hardware allows, having possibly one additional unknown, the convolute, and without changing the current rise-time very much an increase of the load current by the factor of Id/I0=2L/(L+Ld), where Io represents the generator current and L can be easily made much greater than Ld. The benefit of the scheme usage is illustrated in simple circuit simulations for two types of potential applications with static, Ld = const, and dynamic, Ld(t), loads.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A series of joint VNIIEF/LANL explosive magnetic experiments RHSR-0, 1, 2 on radiographic study of perturbations growth at a copper liner boundary with polyethylene or water Explosive magnetic device with a three-layered liner for radiographic study of dynamic strength of materials Dynamics of plasma jets in multiwire arrays Microsecond Z-pinch as ultrasoft X-ray radiation source Wire number dependence of the implosion dynamics, stagnation and radiation output of tungsten wire arrays at Z
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1