基于新巴西总闪电网(BrasilDAT)的巴西东南部闪电探测

K. Naccarato, O. Pinto
{"title":"基于新巴西总闪电网(BrasilDAT)的巴西东南部闪电探测","authors":"K. Naccarato, O. Pinto","doi":"10.1109/ICLP.2012.6344294","DOIUrl":null,"url":null,"abstract":"The Brazilian Total Lightning Network (BrasilDAT) combines advanced lightning detection technologies with modern electronics and already covers 11 States of Brazil. The network is composed of 48 EarthNetworks Lightning Sensors (ENLS), each of them with a GPS-based timing circuit, a digital signal processor (DSP) and onboard storage and internet communication equipment. The ENLS is a wideband system with detection frequency ranging from 1Hz to 12MHz. The wide frequency range enables the sensor to not only detect cloud-to-ground (CG) strokes, but also intra-cloud (IC) pulses. The sensor records whole waveforms of each event and sends them back, in compressed data packets, to the central processor. Instead of using only the peak values, the whole waveforms are used in locating the events and differentiating between IC and CG discharges. Sophisticated digital signal processing technologies are employed on the server side to ensure high-quality detections and to eliminate false locations. This paper presents some preliminary results of two severe storms in Southeastern Brazil that were tracked by BrasilDAT showing the spatial and temporal evolution of IC and CG discharges compared to radar, satellite images and numerical model products. Those results showed the potential of total lightning information for CG lightning warning purposes.","PeriodicalId":400743,"journal":{"name":"2012 International Conference on Lightning Protection (ICLP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Lightning detection in Southeastern Brazil from the new Brazilian Total Lightning Network (BrasilDAT)\",\"authors\":\"K. Naccarato, O. Pinto\",\"doi\":\"10.1109/ICLP.2012.6344294\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Brazilian Total Lightning Network (BrasilDAT) combines advanced lightning detection technologies with modern electronics and already covers 11 States of Brazil. The network is composed of 48 EarthNetworks Lightning Sensors (ENLS), each of them with a GPS-based timing circuit, a digital signal processor (DSP) and onboard storage and internet communication equipment. The ENLS is a wideband system with detection frequency ranging from 1Hz to 12MHz. The wide frequency range enables the sensor to not only detect cloud-to-ground (CG) strokes, but also intra-cloud (IC) pulses. The sensor records whole waveforms of each event and sends them back, in compressed data packets, to the central processor. Instead of using only the peak values, the whole waveforms are used in locating the events and differentiating between IC and CG discharges. Sophisticated digital signal processing technologies are employed on the server side to ensure high-quality detections and to eliminate false locations. This paper presents some preliminary results of two severe storms in Southeastern Brazil that were tracked by BrasilDAT showing the spatial and temporal evolution of IC and CG discharges compared to radar, satellite images and numerical model products. Those results showed the potential of total lightning information for CG lightning warning purposes.\",\"PeriodicalId\":400743,\"journal\":{\"name\":\"2012 International Conference on Lightning Protection (ICLP)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Lightning Protection (ICLP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICLP.2012.6344294\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2012.6344294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

巴西总闪电网络(BrasilDAT)将先进的闪电探测技术与现代电子技术相结合,已经覆盖了巴西的11个州。该网络由48个地球网络闪电传感器(ENLS)组成,每个传感器都有一个基于gps的定时电路,一个数字信号处理器(DSP)以及机载存储和互联网通信设备。ENLS是一个宽带系统,检测频率范围从1Hz到12MHz。宽频率范围使传感器不仅可以检测云对地(CG)冲程,还可以检测云内(IC)脉冲。传感器记录下每个事件的完整波形,并以压缩数据包的形式发回中央处理器。不是只使用峰值,而是使用整个波形来定位事件并区分IC和CG放电。在服务器端采用了复杂的数字信号处理技术,以确保高质量的检测并消除错误的位置。本文介绍了由BrasilDAT跟踪的巴西东南部两次强风暴的一些初步结果,与雷达、卫星图像和数值模式产品相比,显示了IC和CG放电的时空演变。这些结果显示了闪电总信息在CG闪电预警方面的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Lightning detection in Southeastern Brazil from the new Brazilian Total Lightning Network (BrasilDAT)
The Brazilian Total Lightning Network (BrasilDAT) combines advanced lightning detection technologies with modern electronics and already covers 11 States of Brazil. The network is composed of 48 EarthNetworks Lightning Sensors (ENLS), each of them with a GPS-based timing circuit, a digital signal processor (DSP) and onboard storage and internet communication equipment. The ENLS is a wideband system with detection frequency ranging from 1Hz to 12MHz. The wide frequency range enables the sensor to not only detect cloud-to-ground (CG) strokes, but also intra-cloud (IC) pulses. The sensor records whole waveforms of each event and sends them back, in compressed data packets, to the central processor. Instead of using only the peak values, the whole waveforms are used in locating the events and differentiating between IC and CG discharges. Sophisticated digital signal processing technologies are employed on the server side to ensure high-quality detections and to eliminate false locations. This paper presents some preliminary results of two severe storms in Southeastern Brazil that were tracked by BrasilDAT showing the spatial and temporal evolution of IC and CG discharges compared to radar, satellite images and numerical model products. Those results showed the potential of total lightning information for CG lightning warning purposes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Two unprecedented experiments to evaluate the effectiveness of lightning protection systems Investigations of earth termination systems with respect to optimised step voltages Estimation of the minimum shielding failure current causing flashover in overhead lines of the hellenic transmission system through ATP-EMTP simulations Calculating the Lightning Protection System downconductors' grounding resistance at Launch Complex 39B, Kennedy Space Center, Florida Factors influencing the selection and installation of surge protective devices for low voltage systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1