标准及校正实验所研制的亚微米自动精密线标度校正系统

G. Tang
{"title":"标准及校正实验所研制的亚微米自动精密线标度校正系统","authors":"G. Tang","doi":"10.51843/wsproceedings.2017.03","DOIUrl":null,"url":null,"abstract":"A submicron automated precision line scale calibration system was developed at the Standards and Calibration Laboratory (SCL) in Hong Kong. The system provided a measuring capability for line scale of range 0.01 to 750 mm with measurement uncertainty of[0.152 + (0.0005*l)2]1/2 μm (l in mm). The fully automated system used the displacement method and employed an air bearing stage driven by a piezoelectric motor. A pixel-counting system was integrated with a microscope to enhance accuracy. The system used only one laser interferometer to compensate the Abbe error in two lateral directions. Without further calculation, any angular movement leading to an Abbe error would be automatically compensated. The uncertainty contributed from Abbe effects was evaluated to be within 30nm, an error reduction of over 95 % of the Abbe effect when such an arrangement was not in place.","PeriodicalId":432978,"journal":{"name":"NCSL International Workshop & Symposium Conference Proceedings 2017","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Submicron Automated Precision Line Scale Calibration System Developed at the Standards and Calibration Laboratory (SCL) \",\"authors\":\"G. Tang\",\"doi\":\"10.51843/wsproceedings.2017.03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A submicron automated precision line scale calibration system was developed at the Standards and Calibration Laboratory (SCL) in Hong Kong. The system provided a measuring capability for line scale of range 0.01 to 750 mm with measurement uncertainty of[0.152 + (0.0005*l)2]1/2 μm (l in mm). The fully automated system used the displacement method and employed an air bearing stage driven by a piezoelectric motor. A pixel-counting system was integrated with a microscope to enhance accuracy. The system used only one laser interferometer to compensate the Abbe error in two lateral directions. Without further calculation, any angular movement leading to an Abbe error would be automatically compensated. The uncertainty contributed from Abbe effects was evaluated to be within 30nm, an error reduction of over 95 % of the Abbe effect when such an arrangement was not in place.\",\"PeriodicalId\":432978,\"journal\":{\"name\":\"NCSL International Workshop & Symposium Conference Proceedings 2017\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"NCSL International Workshop & Symposium Conference Proceedings 2017\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.51843/wsproceedings.2017.03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"NCSL International Workshop & Symposium Conference Proceedings 2017","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51843/wsproceedings.2017.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

香港标准及校正实验所研制了一套亚微米自动精密线尺校正系统。该系统的测量范围为0.01 ~ 750 mm,测量不确定度为[0.152 + (0.0005*l)2]1/2 μm (l in mm)。全自动化系统采用位移法,采用由压电电机驱动的气浮级。像素计数系统与显微镜集成在一起以提高精度。该系统仅使用一个激光干涉仪在两个横向方向补偿阿贝误差。无需进一步计算,任何导致阿贝误差的角运动都将自动补偿。阿贝效应带来的不确定性被评估为在30nm以内,当这种安排不到位时,误差减少了超过95%的阿贝效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Submicron Automated Precision Line Scale Calibration System Developed at the Standards and Calibration Laboratory (SCL) 
A submicron automated precision line scale calibration system was developed at the Standards and Calibration Laboratory (SCL) in Hong Kong. The system provided a measuring capability for line scale of range 0.01 to 750 mm with measurement uncertainty of[0.152 + (0.0005*l)2]1/2 μm (l in mm). The fully automated system used the displacement method and employed an air bearing stage driven by a piezoelectric motor. A pixel-counting system was integrated with a microscope to enhance accuracy. The system used only one laser interferometer to compensate the Abbe error in two lateral directions. Without further calculation, any angular movement leading to an Abbe error would be automatically compensated. The uncertainty contributed from Abbe effects was evaluated to be within 30nm, an error reduction of over 95 % of the Abbe effect when such an arrangement was not in place.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
From Counting Electrons to Calibrating Ammeters: Improved Methodologies for Traceable Measurements of  Small Electric Currents  Metrology Outreach and Training: A Fulbright Experience in Mexico Characterization of the Dimensions of Internal Gap in a Glass Artifact Using a Laser Triangulation Probe New Automated Coaxial AC Bridge for Rapid Calibration of AC Resistors New NATO Standard ALogP-33 NATO Requirements for Calibration Support of Test & Measurement  Equipment 
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1