Andrea Borghesi, C. Conficoni, M. Lombardi, Andrea Bartolini
{"title":"地中海风格的超级计算机作业调度器——天气太热时少做点事!","authors":"Andrea Borghesi, C. Conficoni, M. Lombardi, Andrea Bartolini","doi":"10.1109/HPCSim.2015.7237025","DOIUrl":null,"url":null,"abstract":"Supercomputers machines, HPC systems in general, embed sophisticated and advanced cooling circuits to remove heat and ensuring the required peak performance. Unfortunately removing heat, by means of cold water or air, costs additional power which decreases the overall supercomputer energy efficiency. Free-cooling uses ambient air instead than chiller to cool down warm air or liquid temperature. The amount of heat which can be removed for-free depends on ambient conditions such as temperature and humidity. Power capping can be used to reduce the supercomputer power dissipation to maximize the cooling efficiency. In this paper we present a power capping approach based on Constraint Programming which enables to estimate at every scheduling interval the power consumption of a given job schedule and to select among all possible job schedules the one which maximizes the supercomputer efficiency.","PeriodicalId":134009,"journal":{"name":"2015 International Conference on High Performance Computing & Simulation (HPCS)","volume":"127 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":"{\"title\":\"MS3: A Mediterranean-stile job scheduler for supercomputers - do less when it's too hot!\",\"authors\":\"Andrea Borghesi, C. Conficoni, M. Lombardi, Andrea Bartolini\",\"doi\":\"10.1109/HPCSim.2015.7237025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Supercomputers machines, HPC systems in general, embed sophisticated and advanced cooling circuits to remove heat and ensuring the required peak performance. Unfortunately removing heat, by means of cold water or air, costs additional power which decreases the overall supercomputer energy efficiency. Free-cooling uses ambient air instead than chiller to cool down warm air or liquid temperature. The amount of heat which can be removed for-free depends on ambient conditions such as temperature and humidity. Power capping can be used to reduce the supercomputer power dissipation to maximize the cooling efficiency. In this paper we present a power capping approach based on Constraint Programming which enables to estimate at every scheduling interval the power consumption of a given job schedule and to select among all possible job schedules the one which maximizes the supercomputer efficiency.\",\"PeriodicalId\":134009,\"journal\":{\"name\":\"2015 International Conference on High Performance Computing & Simulation (HPCS)\",\"volume\":\"127 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on High Performance Computing & Simulation (HPCS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HPCSim.2015.7237025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on High Performance Computing & Simulation (HPCS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HPCSim.2015.7237025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
MS3: A Mediterranean-stile job scheduler for supercomputers - do less when it's too hot!
Supercomputers machines, HPC systems in general, embed sophisticated and advanced cooling circuits to remove heat and ensuring the required peak performance. Unfortunately removing heat, by means of cold water or air, costs additional power which decreases the overall supercomputer energy efficiency. Free-cooling uses ambient air instead than chiller to cool down warm air or liquid temperature. The amount of heat which can be removed for-free depends on ambient conditions such as temperature and humidity. Power capping can be used to reduce the supercomputer power dissipation to maximize the cooling efficiency. In this paper we present a power capping approach based on Constraint Programming which enables to estimate at every scheduling interval the power consumption of a given job schedule and to select among all possible job schedules the one which maximizes the supercomputer efficiency.