中压工业和商业电力系统中多台发电机装置的接地和接地故障保护。一、问题定义

P. Pillai, A. Pierce, B. Bailey, B. Douglas, C. Mozina, C. Normand, D. Love, D. Shipp, G. Dalke, J.R. Jones, J. Fischer, J. Bowen, L. Padden, L. Powell, N. Nichols, R. Young, N. Stringer
{"title":"中压工业和商业电力系统中多台发电机装置的接地和接地故障保护。一、问题定义","authors":"P. Pillai, A. Pierce, B. Bailey, B. Douglas, C. Mozina, C. Normand, D. Love, D. Shipp, G. Dalke, J.R. Jones, J. Fischer, J. Bowen, L. Padden, L. Powell, N. Nichols, R. Young, N. Stringer","doi":"10.1109/PAPCON.2003.1216900","DOIUrl":null,"url":null,"abstract":"The paper discusses typical grounding practices and ground fault protection methods for medium voltage generator stators, highlighting their merits and drawbacks. Particular attention is given to applications of multiple generators connected to a single bus. The paper also provides an overview of the generator damage mechanism during stator ground faults. Problem areas associated with each type of grounding are identified and solutions are discussed. The paper also provides a list of references on the topic. The paper is intended as a guide to aid engineers in selecting adequate grounding and ground fault protection schemes for medium voltage industrial and commercial generators for new installations, for evaluating existing systems, and for future expansion of facilities, to minimize generator damage from stator ground faults. These topics are presented in four separate papers. Part 1 covers scope, introduction, user examples of stator ground failure, and theoretical basis for the problem.","PeriodicalId":202482,"journal":{"name":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Grounding and ground fault protection of multiple generator installations on medium-voltage industrial and commercial power systems. I. The problem defined\",\"authors\":\"P. Pillai, A. Pierce, B. Bailey, B. Douglas, C. Mozina, C. Normand, D. Love, D. Shipp, G. Dalke, J.R. Jones, J. Fischer, J. Bowen, L. Padden, L. Powell, N. Nichols, R. Young, N. Stringer\",\"doi\":\"10.1109/PAPCON.2003.1216900\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper discusses typical grounding practices and ground fault protection methods for medium voltage generator stators, highlighting their merits and drawbacks. Particular attention is given to applications of multiple generators connected to a single bus. The paper also provides an overview of the generator damage mechanism during stator ground faults. Problem areas associated with each type of grounding are identified and solutions are discussed. The paper also provides a list of references on the topic. The paper is intended as a guide to aid engineers in selecting adequate grounding and ground fault protection schemes for medium voltage industrial and commercial generators for new installations, for evaluating existing systems, and for future expansion of facilities, to minimize generator damage from stator ground faults. These topics are presented in four separate papers. Part 1 covers scope, introduction, user examples of stator ground failure, and theoretical basis for the problem.\",\"PeriodicalId\":202482,\"journal\":{\"name\":\"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PAPCON.2003.1216900\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAPCON.2003.1216900","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文论述了中压发电机定子接地的典型做法和接地故障保护方法,重点介绍了它们的优缺点。特别注意连接到单个母线上的多个发电机的应用。本文还概述了发电机定子接地故障时的损坏机理。确定了与每种接地类型相关的问题区域并讨论了解决方案。本文还提供了有关该主题的参考文献列表。本文旨在作为一份指南,帮助工程师为新安装的中压工业和商业发电机选择适当的接地和接地故障保护方案,用于评估现有系统,以及未来的设施扩建,以尽量减少发电机定子接地故障造成的损坏。这些主题分别在四篇论文中提出。第1部分涵盖范围,介绍,定子接地故障的用户示例,以及问题的理论基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Grounding and ground fault protection of multiple generator installations on medium-voltage industrial and commercial power systems. I. The problem defined
The paper discusses typical grounding practices and ground fault protection methods for medium voltage generator stators, highlighting their merits and drawbacks. Particular attention is given to applications of multiple generators connected to a single bus. The paper also provides an overview of the generator damage mechanism during stator ground faults. Problem areas associated with each type of grounding are identified and solutions are discussed. The paper also provides a list of references on the topic. The paper is intended as a guide to aid engineers in selecting adequate grounding and ground fault protection schemes for medium voltage industrial and commercial generators for new installations, for evaluating existing systems, and for future expansion of facilities, to minimize generator damage from stator ground faults. These topics are presented in four separate papers. Part 1 covers scope, introduction, user examples of stator ground failure, and theoretical basis for the problem.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Resonant filter applications in electronic ballast Novel method in decreasing grounding resistances of urban substations by utilizing peripheral geographical conditions Practical design considerations of a single-stage single-switch parallel PFC converter for universal voltage applications Drug delivery studies on electrostatically charged dry powder inhaler aerosols using a glass bead lung model A simple rolling mill model with linear quadratic optimal controller
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1