{"title":"基于新型无变压器集成电源变换器的不间断电源","authors":"E. D. dos Santos, O. Nezamuddin","doi":"10.1109/PECI.2014.6804561","DOIUrl":null,"url":null,"abstract":"This paper proposes an on-line transformerless UPS system based on the integrated power electronics converters that is able to control the input power factor, charge the battery, and guarantee backup operation in the case of utility power outage. The main advantages of the proposed UPS are: 1) active power factor correction (PFC) without any feedback control, and 2) integrated functions of the battery charger circuit and PFC by using only three power switches. Details regarding the operation modes of the system and modulation strategy are presented. Simulation results are presented to validate the theoretical expectations.","PeriodicalId":352005,"journal":{"name":"2014 Power and Energy Conference at Illinois (PECI)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Uninterrupted power supply based on a new transformerless integrated power converter\",\"authors\":\"E. D. dos Santos, O. Nezamuddin\",\"doi\":\"10.1109/PECI.2014.6804561\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes an on-line transformerless UPS system based on the integrated power electronics converters that is able to control the input power factor, charge the battery, and guarantee backup operation in the case of utility power outage. The main advantages of the proposed UPS are: 1) active power factor correction (PFC) without any feedback control, and 2) integrated functions of the battery charger circuit and PFC by using only three power switches. Details regarding the operation modes of the system and modulation strategy are presented. Simulation results are presented to validate the theoretical expectations.\",\"PeriodicalId\":352005,\"journal\":{\"name\":\"2014 Power and Energy Conference at Illinois (PECI)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 Power and Energy Conference at Illinois (PECI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECI.2014.6804561\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Power and Energy Conference at Illinois (PECI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECI.2014.6804561","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Uninterrupted power supply based on a new transformerless integrated power converter
This paper proposes an on-line transformerless UPS system based on the integrated power electronics converters that is able to control the input power factor, charge the battery, and guarantee backup operation in the case of utility power outage. The main advantages of the proposed UPS are: 1) active power factor correction (PFC) without any feedback control, and 2) integrated functions of the battery charger circuit and PFC by using only three power switches. Details regarding the operation modes of the system and modulation strategy are presented. Simulation results are presented to validate the theoretical expectations.