在电视空白网络中传输生物医学信号

J. Pinifolo, S. Rimer
{"title":"在电视空白网络中传输生物医学信号","authors":"J. Pinifolo, S. Rimer","doi":"10.1109/ISTAFRICA.2016.7530634","DOIUrl":null,"url":null,"abstract":"In an effort to examine the heart condition, electrodes of Electrocardiogram (ECG) machine are placed on the skin of the patient thereby detecting depolarization and repolarisation of the myocardium which is the muscular tissue of the heart. The readings are therefore displayed on an electrocardiograph. It is therefore important to note that there is a technical limitation in obtaining readings in the sense that upon movement of the patient, the equipment equally moves hence artefact making interpretation difficult. This paper is therefore trying to eliminate the stated technical problem by designing a low cost solution incorporating an instrumentation amplifier with high common mode rejection ratio (CMRR) and the biomedical signal is transmitted from the patient in a remote hospital to the heart specialist for analysis using TV White Spaces network.","PeriodicalId":326074,"journal":{"name":"2016 IST-Africa Week Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transmitting a biomedical signal in a TV White Spaces Network\",\"authors\":\"J. Pinifolo, S. Rimer\",\"doi\":\"10.1109/ISTAFRICA.2016.7530634\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In an effort to examine the heart condition, electrodes of Electrocardiogram (ECG) machine are placed on the skin of the patient thereby detecting depolarization and repolarisation of the myocardium which is the muscular tissue of the heart. The readings are therefore displayed on an electrocardiograph. It is therefore important to note that there is a technical limitation in obtaining readings in the sense that upon movement of the patient, the equipment equally moves hence artefact making interpretation difficult. This paper is therefore trying to eliminate the stated technical problem by designing a low cost solution incorporating an instrumentation amplifier with high common mode rejection ratio (CMRR) and the biomedical signal is transmitted from the patient in a remote hospital to the heart specialist for analysis using TV White Spaces network.\",\"PeriodicalId\":326074,\"journal\":{\"name\":\"2016 IST-Africa Week Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IST-Africa Week Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISTAFRICA.2016.7530634\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IST-Africa Week Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISTAFRICA.2016.7530634","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了检查心脏状况,将心电图(ECG)机的电极放置在患者的皮肤上,从而检测心脏肌肉组织心肌的去极化和复极化。读数因此显示在心电图仪上。因此,重要的是要注意,在获得读数的意义上存在技术限制,即在患者移动时,设备也会移动,因此人工制品使解释变得困难。因此,本文试图通过设计一种低成本的解决方案来消除上述技术问题,该解决方案结合了具有高共模抑制比(CMRR)的仪器放大器,并将生物医学信号从远程医院的患者传输给心脏专家,以便使用电视空白网络进行分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Transmitting a biomedical signal in a TV White Spaces Network
In an effort to examine the heart condition, electrodes of Electrocardiogram (ECG) machine are placed on the skin of the patient thereby detecting depolarization and repolarisation of the myocardium which is the muscular tissue of the heart. The readings are therefore displayed on an electrocardiograph. It is therefore important to note that there is a technical limitation in obtaining readings in the sense that upon movement of the patient, the equipment equally moves hence artefact making interpretation difficult. This paper is therefore trying to eliminate the stated technical problem by designing a low cost solution incorporating an instrumentation amplifier with high common mode rejection ratio (CMRR) and the biomedical signal is transmitted from the patient in a remote hospital to the heart specialist for analysis using TV White Spaces network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
ICT adoption and use in Zimbabwean SMEs A security algorithm for wireless sensor networks in the Internet of Things paradigm The extent to which the POPI act makes provision for patient privacy in mobile personal health record systems Prototyping Smart City applications over large scale M2M testbed Sustainable cooperative distance learning system for education in developing countries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1