{"title":"嵌入式电机缠绕部件热监测的光纤传感性能评价","authors":"A. Mohammed, S. Djurović","doi":"10.1109/MECO.2016.7525706","DOIUrl":null,"url":null,"abstract":"This paper investigates the thermal monitoring performance potential of fibre-optic (FO) thermal sensors embedded into the structure of random wound coils. The implications of FO sensor packaging and installation procedure on thermal monitoring performance are assessed on a prototype coil in a series of laboratory experiments in a controlled thermal ambient. It is shown that, while the procedure of embedding the FO sensor into the coil structure alters its operational characteristics to an extent, the resulting in-situ hot spot thermal monitoring provides a reliable output when benchmarked with conventional thermocouple measurements.","PeriodicalId":253666,"journal":{"name":"2016 5th Mediterranean Conference on Embedded Computing (MECO)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Evaluation of fiber-optic sensing performance for embedded thermal monitoring of electric machinery wound components\",\"authors\":\"A. Mohammed, S. Djurović\",\"doi\":\"10.1109/MECO.2016.7525706\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates the thermal monitoring performance potential of fibre-optic (FO) thermal sensors embedded into the structure of random wound coils. The implications of FO sensor packaging and installation procedure on thermal monitoring performance are assessed on a prototype coil in a series of laboratory experiments in a controlled thermal ambient. It is shown that, while the procedure of embedding the FO sensor into the coil structure alters its operational characteristics to an extent, the resulting in-situ hot spot thermal monitoring provides a reliable output when benchmarked with conventional thermocouple measurements.\",\"PeriodicalId\":253666,\"journal\":{\"name\":\"2016 5th Mediterranean Conference on Embedded Computing (MECO)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 5th Mediterranean Conference on Embedded Computing (MECO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MECO.2016.7525706\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 5th Mediterranean Conference on Embedded Computing (MECO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MECO.2016.7525706","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of fiber-optic sensing performance for embedded thermal monitoring of electric machinery wound components
This paper investigates the thermal monitoring performance potential of fibre-optic (FO) thermal sensors embedded into the structure of random wound coils. The implications of FO sensor packaging and installation procedure on thermal monitoring performance are assessed on a prototype coil in a series of laboratory experiments in a controlled thermal ambient. It is shown that, while the procedure of embedding the FO sensor into the coil structure alters its operational characteristics to an extent, the resulting in-situ hot spot thermal monitoring provides a reliable output when benchmarked with conventional thermocouple measurements.