Liu Jiangui, A. Fremout, P. Bruyndonckx, S. Tavernier, J. Loude, C. Morel
{"title":"来自Hamamatsu和Perkin-Elmer的不同类型雪崩光电二极管的评价","authors":"Liu Jiangui, A. Fremout, P. Bruyndonckx, S. Tavernier, J. Loude, C. Morel","doi":"10.1109/NSSMIC.2001.1009694","DOIUrl":null,"url":null,"abstract":"Avalanche photodiodes (APD) could replace photomultiplier tubes (PMT) in some areas like positron emission tomography (PET). It is therefore important to study their performance. In this study, we have tested two types of APD's, the Hamamatsu S5345W and the Perkin-Elmer C30719E. We evaluated and compared the dark current, the gain and the excess noise factor of these two APD types.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Evaluation of different types of avalanche photo diodes from Hamamatsu and Perkin-Elmer\",\"authors\":\"Liu Jiangui, A. Fremout, P. Bruyndonckx, S. Tavernier, J. Loude, C. Morel\",\"doi\":\"10.1109/NSSMIC.2001.1009694\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Avalanche photodiodes (APD) could replace photomultiplier tubes (PMT) in some areas like positron emission tomography (PET). It is therefore important to study their performance. In this study, we have tested two types of APD's, the Hamamatsu S5345W and the Perkin-Elmer C30719E. We evaluated and compared the dark current, the gain and the excess noise factor of these two APD types.\",\"PeriodicalId\":159123,\"journal\":{\"name\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2001.1009694\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1009694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of different types of avalanche photo diodes from Hamamatsu and Perkin-Elmer
Avalanche photodiodes (APD) could replace photomultiplier tubes (PMT) in some areas like positron emission tomography (PET). It is therefore important to study their performance. In this study, we have tested two types of APD's, the Hamamatsu S5345W and the Perkin-Elmer C30719E. We evaluated and compared the dark current, the gain and the excess noise factor of these two APD types.