4通道心磁扫描仪的研制及9通道心磁扫描仪诊断心脏异常的技术要求

M. Budnyk, Volodymyr Sosnytskyi, I. Voitovych, V. Maiko, Y. Minov, P. Sutkovyi, Oleksandr Zakorchenyi, T. Ryzhenko, V. Budnyk
{"title":"4通道心磁扫描仪的研制及9通道心磁扫描仪诊断心脏异常的技术要求","authors":"M. Budnyk, Volodymyr Sosnytskyi, I. Voitovych, V. Maiko, Y. Minov, P. Sutkovyi, Oleksandr Zakorchenyi, T. Ryzhenko, V. Budnyk","doi":"10.1109/IDAACS.2011.6072717","DOIUrl":null,"url":null,"abstract":"Detail description of hardware and software of novel Ukrainian generation of magnetocardiographic apparatus — cardiomagnetic scanner CARDIOMAGSCAN have been presented. This cheaper supersensitive device includes 4 signal SQUID-channels, electrocardiograph, and automatic electromechanical system for patient scanning. Scanner is enabled to perform observation of the human heart during 15 minutes at unshielded environment. Device is intended to non-invasive medical diagnostics of cardiology diseases with help of advanced software including early stages, difficult-to-diagnose cases, and asymptomatic forms.","PeriodicalId":106306,"journal":{"name":"Proceedings of the 6th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Development of 4-channel cardiomagnetic scaner and technical requirements for 9-channel scaner to diagnose the heart abnormalities\",\"authors\":\"M. Budnyk, Volodymyr Sosnytskyi, I. Voitovych, V. Maiko, Y. Minov, P. Sutkovyi, Oleksandr Zakorchenyi, T. Ryzhenko, V. Budnyk\",\"doi\":\"10.1109/IDAACS.2011.6072717\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Detail description of hardware and software of novel Ukrainian generation of magnetocardiographic apparatus — cardiomagnetic scanner CARDIOMAGSCAN have been presented. This cheaper supersensitive device includes 4 signal SQUID-channels, electrocardiograph, and automatic electromechanical system for patient scanning. Scanner is enabled to perform observation of the human heart during 15 minutes at unshielded environment. Device is intended to non-invasive medical diagnostics of cardiology diseases with help of advanced software including early stages, difficult-to-diagnose cases, and asymptomatic forms.\",\"PeriodicalId\":106306,\"journal\":{\"name\":\"Proceedings of the 6th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 6th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IDAACS.2011.6072717\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 6th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IDAACS.2011.6072717","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

详细介绍了乌克兰新一代心脏磁图仪——CARDIOMAGSCAN的硬件和软件。这种便宜的超灵敏设备包括4个信号squid通道,心电图仪和用于患者扫描的自动机电系统。扫描仪可在无屏蔽环境下对人体心脏进行15分钟的观察。该设备旨在借助先进的软件对心脏病进行无创医学诊断,包括早期阶段、难以诊断的病例和无症状的形式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of 4-channel cardiomagnetic scaner and technical requirements for 9-channel scaner to diagnose the heart abnormalities
Detail description of hardware and software of novel Ukrainian generation of magnetocardiographic apparatus — cardiomagnetic scanner CARDIOMAGSCAN have been presented. This cheaper supersensitive device includes 4 signal SQUID-channels, electrocardiograph, and automatic electromechanical system for patient scanning. Scanner is enabled to perform observation of the human heart during 15 minutes at unshielded environment. Device is intended to non-invasive medical diagnostics of cardiology diseases with help of advanced software including early stages, difficult-to-diagnose cases, and asymptomatic forms.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Automated measurement system based on digital intertial sensors for the study of human body movement Assessment of probabilistic parameters of alarm security detectors taking uncertain noise into account Special areas detection on agricultural fields images using evaluations of local brightness variability Net Present Value (NPV) as a tool supporting effective project management Photoplethysmography detection by smartphone's videocamera
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1