用于校准商用电容和tan δ测量电桥的电容-电阻组的制作

J. Jung, A. Faisal, Young Seob Lee, Kyu-Tae Kim
{"title":"用于校准商用电容和tan δ测量电桥的电容-电阻组的制作","authors":"J. Jung, A. Faisal, Young Seob Lee, Kyu-Tae Kim","doi":"10.1109/CPEM.2014.6898534","DOIUrl":null,"url":null,"abstract":"A capacitor-resistor combined bank to calibrate both the capacitance ratio and dissipation factor of the commercial capacitance and tan δ measuring bridge is fabricated. The fabricated portable working standards as a secondary standard for ratio calibration are realized by connecting the double shielded capacitors in parallel employing the substitution and build-up technique, whereas, the standards for dissipation calibration are attained by connecting shielded capacitors in parallel with a shielded T-resistor network. The calibration results for the several commercial bridges are presented and compared with specification provided by manufacturer including the measurement uncertainty.","PeriodicalId":256575,"journal":{"name":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Fabrication of capacitor-resistor bank for calibrating commercial capacitance and tan δ measuring bridge\",\"authors\":\"J. Jung, A. Faisal, Young Seob Lee, Kyu-Tae Kim\",\"doi\":\"10.1109/CPEM.2014.6898534\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A capacitor-resistor combined bank to calibrate both the capacitance ratio and dissipation factor of the commercial capacitance and tan δ measuring bridge is fabricated. The fabricated portable working standards as a secondary standard for ratio calibration are realized by connecting the double shielded capacitors in parallel employing the substitution and build-up technique, whereas, the standards for dissipation calibration are attained by connecting shielded capacitors in parallel with a shielded T-resistor network. The calibration results for the several commercial bridges are presented and compared with specification provided by manufacturer including the measurement uncertainty.\",\"PeriodicalId\":256575,\"journal\":{\"name\":\"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2014.6898534\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2014.6898534","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

制作了一种电容-电阻组合组,用于校准商用电容和tan δ测量桥的电容比和耗散系数。采用替换叠加技术将双屏蔽电容器并联连接,实现了作为比率校准次级标准的便携式工作标准,而将屏蔽电容器与屏蔽t电阻网络并联连接,实现了耗散校准标准。给出了几座商业桥梁的校准结果,并与制造商提供的包括测量不确定度的规格进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fabrication of capacitor-resistor bank for calibrating commercial capacitance and tan δ measuring bridge
A capacitor-resistor combined bank to calibrate both the capacitance ratio and dissipation factor of the commercial capacitance and tan δ measuring bridge is fabricated. The fabricated portable working standards as a secondary standard for ratio calibration are realized by connecting the double shielded capacitors in parallel employing the substitution and build-up technique, whereas, the standards for dissipation calibration are attained by connecting shielded capacitors in parallel with a shielded T-resistor network. The calibration results for the several commercial bridges are presented and compared with specification provided by manufacturer including the measurement uncertainty.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Stability tests of electronic calibration units Dynamic range improvement of THz spectroscopy Realization of a traceable power quality calibration facility in full accordance with the IEC 61000-4-30 standard Uncertainty of communication signals measurement Determination of the Planck constant at the national institute of Standards and Technology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1