短传输线模型的性能

M. Taleb, Mohamed Jassim Ditto, T. Bouthiba
{"title":"短传输线模型的性能","authors":"M. Taleb, Mohamed Jassim Ditto, T. Bouthiba","doi":"10.1109/IEEEGCC.2006.5686249","DOIUrl":null,"url":null,"abstract":"Performance of a short transmission line models is investigated in this paper. The performance accuracy is assessed by considering three dynamic models for the line. Computer simulations show that the results of the dynamic models agree with the results of the standard line model during steady state operations but they disagree with it during transient circumstances. In controlling the level of transients, the paper results recommend that in energizing a line, it is preferable to switch-on the poles of circuit breaker in a sequential manner rather than in a simultaneous manner. Also, simulation results show that transient voltages in a loaded line case are more severe than the unloaded line case.","PeriodicalId":433452,"journal":{"name":"2006 IEEE GCC Conference (GCC)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Performance of short transmission lines models\",\"authors\":\"M. Taleb, Mohamed Jassim Ditto, T. Bouthiba\",\"doi\":\"10.1109/IEEEGCC.2006.5686249\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Performance of a short transmission line models is investigated in this paper. The performance accuracy is assessed by considering three dynamic models for the line. Computer simulations show that the results of the dynamic models agree with the results of the standard line model during steady state operations but they disagree with it during transient circumstances. In controlling the level of transients, the paper results recommend that in energizing a line, it is preferable to switch-on the poles of circuit breaker in a sequential manner rather than in a simultaneous manner. Also, simulation results show that transient voltages in a loaded line case are more severe than the unloaded line case.\",\"PeriodicalId\":433452,\"journal\":{\"name\":\"2006 IEEE GCC Conference (GCC)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE GCC Conference (GCC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEEEGCC.2006.5686249\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE GCC Conference (GCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEEEGCC.2006.5686249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

本文研究了一种短传输线模型的性能。通过考虑线路的三种动态模型来评估性能精度。计算机模拟结果表明,在稳态运行时,动态模型的结果与标准线模型的结果一致,但在瞬态情况下,动态模型的结果与标准线模型的结果不一致。在控制暂态电平方面,本文的结果建议,在给线路通电时,断路器的两极按顺序接通比同时接通好。仿真结果还表明,负载情况下的暂态电压比空载情况下的瞬态电压要大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance of short transmission lines models
Performance of a short transmission line models is investigated in this paper. The performance accuracy is assessed by considering three dynamic models for the line. Computer simulations show that the results of the dynamic models agree with the results of the standard line model during steady state operations but they disagree with it during transient circumstances. In controlling the level of transients, the paper results recommend that in energizing a line, it is preferable to switch-on the poles of circuit breaker in a sequential manner rather than in a simultaneous manner. Also, simulation results show that transient voltages in a loaded line case are more severe than the unloaded line case.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Perturbation method based evaluation of power system voltage security Allocating generation to loads and line flows for transmission open access Z-transform PML algorithm for truncating metamaterial FDTD domains A personal search agent system Optimum design of high frequency transformer for compact and light weight switch mode power supplies (SMPS)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1