眼前段高分辨率血流成像

D. Kruse, R. Silverman, D. Coleman, S. Erickson, K. Ferrara
{"title":"眼前段高分辨率血流成像","authors":"D. Kruse, R. Silverman, D. Coleman, S. Erickson, K. Ferrara","doi":"10.1109/ULTSYM.1999.849276","DOIUrl":null,"url":null,"abstract":"A new high frequency ultrasound system has been developed to visualize and measure blood flow parameters in the superficial microvasculature with a resolution of 40 /spl mu/m. A recently reported method (D.E. Kruse et al., 1998, R.H. Silverman et al., 1999), which the authors call swept-scan or swept Doppler, has been developed to rapidly acquire 2-D frames data for blood velocity estimation using sweeping scans of a single element focused transducer. Using this new method combined with the M-mode technique, experiments were performed to quantify blood flow in the highly vascular, anterior segment of the eye. Scans of radial vessels in the rabbit iris indicate that blood flow can be mapped in arterioles down to 40 /spl mu/m in diameter with velocities as low as 0.5 mm/sec. Furthermore, preliminary estimates of the effect of vasoactive drugs show that blood flow changes due to application of topical atropine can be measured in the 200 /spl mu/m rabbit major arterial circle with both M-mode and swept-scan techniques. In particular, the M-mode technique was sufficiently sensitive to detect changes in peak systolic and diastolic blood flow, and these velocity measurements were consistent with those obtained from the swept-scan.","PeriodicalId":339424,"journal":{"name":"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"High resolution blood flow mapping in the anterior segment of the eye\",\"authors\":\"D. Kruse, R. Silverman, D. Coleman, S. Erickson, K. Ferrara\",\"doi\":\"10.1109/ULTSYM.1999.849276\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new high frequency ultrasound system has been developed to visualize and measure blood flow parameters in the superficial microvasculature with a resolution of 40 /spl mu/m. A recently reported method (D.E. Kruse et al., 1998, R.H. Silverman et al., 1999), which the authors call swept-scan or swept Doppler, has been developed to rapidly acquire 2-D frames data for blood velocity estimation using sweeping scans of a single element focused transducer. Using this new method combined with the M-mode technique, experiments were performed to quantify blood flow in the highly vascular, anterior segment of the eye. Scans of radial vessels in the rabbit iris indicate that blood flow can be mapped in arterioles down to 40 /spl mu/m in diameter with velocities as low as 0.5 mm/sec. Furthermore, preliminary estimates of the effect of vasoactive drugs show that blood flow changes due to application of topical atropine can be measured in the 200 /spl mu/m rabbit major arterial circle with both M-mode and swept-scan techniques. In particular, the M-mode technique was sufficiently sensitive to detect changes in peak systolic and diastolic blood flow, and these velocity measurements were consistent with those obtained from the swept-scan.\",\"PeriodicalId\":339424,\"journal\":{\"name\":\"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1999.849276\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1999.849276","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

一种新型的高频超声系统已被开发出来,用于可视化和测量浅表微血管的血流参数,分辨率为40 /spl μ m /m。最近报道了一种方法(D.E. Kruse等人,1998年,R.H. Silverman等人,1999年),作者称之为扫频扫描或扫频多普勒,通过对单个元件聚焦传感器进行扫频扫描,快速获取二维帧数据,以估计血流速度。将这种新方法与m模式技术相结合,进行了实验,以量化血管密集的眼睛前段的血流量。对兔虹膜径向血管的扫描表明,可以在直径小至40 /spl μ m,速度低至0.5 mm/秒的小动脉中绘制血流图。此外,血管活性药物作用的初步估计表明,使用m模式和扫描技术可以在200 /spl mu/m的兔子大动脉圈中测量由于局部应用阿托品而引起的血流变化。特别是,m模式技术在检测收缩期和舒张期血流峰值变化方面足够敏感,这些速度测量结果与扫描结果一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High resolution blood flow mapping in the anterior segment of the eye
A new high frequency ultrasound system has been developed to visualize and measure blood flow parameters in the superficial microvasculature with a resolution of 40 /spl mu/m. A recently reported method (D.E. Kruse et al., 1998, R.H. Silverman et al., 1999), which the authors call swept-scan or swept Doppler, has been developed to rapidly acquire 2-D frames data for blood velocity estimation using sweeping scans of a single element focused transducer. Using this new method combined with the M-mode technique, experiments were performed to quantify blood flow in the highly vascular, anterior segment of the eye. Scans of radial vessels in the rabbit iris indicate that blood flow can be mapped in arterioles down to 40 /spl mu/m in diameter with velocities as low as 0.5 mm/sec. Furthermore, preliminary estimates of the effect of vasoactive drugs show that blood flow changes due to application of topical atropine can be measured in the 200 /spl mu/m rabbit major arterial circle with both M-mode and swept-scan techniques. In particular, the M-mode technique was sufficiently sensitive to detect changes in peak systolic and diastolic blood flow, and these velocity measurements were consistent with those obtained from the swept-scan.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fast beam shape computation and wave propagation via the Radon transform Experimental verification of acoustic saturation Ultrasonic characterization of emulsions: milk and water in oil High-contrast RF correlation imaging of defects in food package seals Analysis of resolution for an amplitude steered array
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1