一种用于血清细菌检测的高灵敏度微流控装置

M. Al-Adhami, E. Tan, G. Rao, Y. Rostov
{"title":"一种用于血清细菌检测的高灵敏度微流控装置","authors":"M. Al-Adhami, E. Tan, G. Rao, Y. Rostov","doi":"10.1109/HIC.2017.8227601","DOIUrl":null,"url":null,"abstract":"Highly sensitive device to detect bacteria in blood serum is presented. The device comprises of a microfluidic component and an electronic reader. The microfluidic cassette acts as an enclosed vial. It is filled with the sample after mixing with an indicator dye. Then, it is inserted into a kinetics fluorometer. The rate of the fluorescence increase is proportional to the number of viable cells in the sample. The fluorometer is portable. The device was tested with both lyophilized and fresh whole blood serums that were spiked with E.coli. Concentrations as low as 10 CFU/mL were detected. This paper discusses both the procedure to detect the bacteria as well as the results for different bacterial concentrations.","PeriodicalId":120815,"journal":{"name":"2017 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A highly sensitive microfluidic device for bacterial detection in blood serum\",\"authors\":\"M. Al-Adhami, E. Tan, G. Rao, Y. Rostov\",\"doi\":\"10.1109/HIC.2017.8227601\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Highly sensitive device to detect bacteria in blood serum is presented. The device comprises of a microfluidic component and an electronic reader. The microfluidic cassette acts as an enclosed vial. It is filled with the sample after mixing with an indicator dye. Then, it is inserted into a kinetics fluorometer. The rate of the fluorescence increase is proportional to the number of viable cells in the sample. The fluorometer is portable. The device was tested with both lyophilized and fresh whole blood serums that were spiked with E.coli. Concentrations as low as 10 CFU/mL were detected. This paper discusses both the procedure to detect the bacteria as well as the results for different bacterial concentrations.\",\"PeriodicalId\":120815,\"journal\":{\"name\":\"2017 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HIC.2017.8227601\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Healthcare Innovations and Point of Care Technologies (HI-POCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HIC.2017.8227601","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

介绍了一种高灵敏度的血清细菌检测装置。该装置包括微流控元件和电子阅读器。微流体盒作为一个封闭的小瓶。与指示染料混合后,将样品填满。然后,将其插入动力学荧光计中。荧光增加的速率与样品中活细胞的数量成正比。荧光计是便携式的。该装置在冻干和新鲜全血血清中进行了测试,全血血清中加入了大肠杆菌。浓度低至10 CFU/mL。本文讨论了细菌的检测过程以及不同细菌浓度下的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A highly sensitive microfluidic device for bacterial detection in blood serum
Highly sensitive device to detect bacteria in blood serum is presented. The device comprises of a microfluidic component and an electronic reader. The microfluidic cassette acts as an enclosed vial. It is filled with the sample after mixing with an indicator dye. Then, it is inserted into a kinetics fluorometer. The rate of the fluorescence increase is proportional to the number of viable cells in the sample. The fluorometer is portable. The device was tested with both lyophilized and fresh whole blood serums that were spiked with E.coli. Concentrations as low as 10 CFU/mL were detected. This paper discusses both the procedure to detect the bacteria as well as the results for different bacterial concentrations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Label-free detection of lactoferrin and beta-2-microglobuin in contrived tear film using a low-cost electrical biosensor chip Development of an AI-based non-invasive Pulse AudioGram monitoring device for arrhythmia screening Comparison of sleep parameters assessed by actigraphy of healthy young adults from a small town and a megalopolis in an emerging country A dedicated bit-serial hardware neuron for massively-parallel neural networks in fast epilepsy diagnosis A feasibility study on a low-cost, smartphone-based solution of pulse transit time measurement using cardio-mechanical signals
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1