Qi-yu Wang, Lishuang Mou, Jinyang Feng, Chun-jian Li, D. Su, Shuqing Wu
{"title":"第十届国际绝对重力仪比较(ICAG-2017)期间gPhone重力仪-119重力变化观测研究","authors":"Qi-yu Wang, Lishuang Mou, Jinyang Feng, Chun-jian Li, D. Su, Shuqing Wu","doi":"10.1117/12.2512020","DOIUrl":null,"url":null,"abstract":"The 10th International Comparison of Absolute Gravimeters (ICAG-2017) was held in Changping campus of National Institute of Metrology (NIM), China in October 2017. The observation of gravity variations using relative gravimeters plays an important role in absolute gravimeter comparison and the link of gravity reference value after comparison. We carried out a continuous observation of gPhone gravimeter-119 simultaneously alongside a superconductive gravimeter iGrav-012 for several months. The calibration factor of gPhone-119 is determined to be 0.99355±0.00004 with a precision of 0.004%. When the observation time exceeds 33000 minutes, the calibration values and uncertainties tend to be stable and the precision is better than 0.01%. The non-tidal gravity changes during ICAG-2017 recorded by gPhone-119 are analyzed. The tendency of gravity variations is roughly consistent with that recorded by iGrav-012. The result indicates that the peak-to-peak value of gravity changes is less than 1.5 μGal during the period of ICAG-2017.","PeriodicalId":115119,"journal":{"name":"International Symposium on Precision Engineering Measurement and Instrumentation","volume":"63 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Investigation on gPhone gravimeter-119 for gravity variations observation during the 10th International Comparison of Absolute Gravimeters (ICAG-2017)\",\"authors\":\"Qi-yu Wang, Lishuang Mou, Jinyang Feng, Chun-jian Li, D. Su, Shuqing Wu\",\"doi\":\"10.1117/12.2512020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The 10th International Comparison of Absolute Gravimeters (ICAG-2017) was held in Changping campus of National Institute of Metrology (NIM), China in October 2017. The observation of gravity variations using relative gravimeters plays an important role in absolute gravimeter comparison and the link of gravity reference value after comparison. We carried out a continuous observation of gPhone gravimeter-119 simultaneously alongside a superconductive gravimeter iGrav-012 for several months. The calibration factor of gPhone-119 is determined to be 0.99355±0.00004 with a precision of 0.004%. When the observation time exceeds 33000 minutes, the calibration values and uncertainties tend to be stable and the precision is better than 0.01%. The non-tidal gravity changes during ICAG-2017 recorded by gPhone-119 are analyzed. The tendency of gravity variations is roughly consistent with that recorded by iGrav-012. The result indicates that the peak-to-peak value of gravity changes is less than 1.5 μGal during the period of ICAG-2017.\",\"PeriodicalId\":115119,\"journal\":{\"name\":\"International Symposium on Precision Engineering Measurement and Instrumentation\",\"volume\":\"63 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Symposium on Precision Engineering Measurement and Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2512020\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Precision Engineering Measurement and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2512020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

第十届绝对重力仪国际比较大会(ICAG-2017)于2017年10月在中国计量科学研究院昌平校区举行。相对重力仪观测重力变化在绝对重力仪比较和比较后重力参考值的联系中起着重要的作用。我们对gPhone重力仪-119与超导重力仪iGrav-012同时进行了几个月的连续观测。确定gPhone-119的校准因子为0.99355±0.00004,精度为0.004%。当观测时间超过33000 min时,定标值和不确定度趋于稳定,精度优于0.01%。对gPhone-119记录的ICAG-2017非潮重力变化进行了分析。重力变化的趋势与iGrav-012记录的大致一致。结果表明:ICAG-2017期间重力变化峰间值小于1.5 μGal;
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Investigation on gPhone gravimeter-119 for gravity variations observation during the 10th International Comparison of Absolute Gravimeters (ICAG-2017)
The 10th International Comparison of Absolute Gravimeters (ICAG-2017) was held in Changping campus of National Institute of Metrology (NIM), China in October 2017. The observation of gravity variations using relative gravimeters plays an important role in absolute gravimeter comparison and the link of gravity reference value after comparison. We carried out a continuous observation of gPhone gravimeter-119 simultaneously alongside a superconductive gravimeter iGrav-012 for several months. The calibration factor of gPhone-119 is determined to be 0.99355±0.00004 with a precision of 0.004%. When the observation time exceeds 33000 minutes, the calibration values and uncertainties tend to be stable and the precision is better than 0.01%. The non-tidal gravity changes during ICAG-2017 recorded by gPhone-119 are analyzed. The tendency of gravity variations is roughly consistent with that recorded by iGrav-012. The result indicates that the peak-to-peak value of gravity changes is less than 1.5 μGal during the period of ICAG-2017.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel two-dimensional inductive sensor based on planar coils Combining compound eyes and human eye: a hybrid bionic imaging method for FOV extension and foveated vision Measurement of deionized water density based on single silicon sphere Research of variable-frequency big current calibration The optimization of segment’s axial support point for large astronomical telescopes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1