F. Cattivelli, H. Garudadri
{"title":"基于脉搏到达时间和心率的无创无袖套血压自适应校准","authors":"F. Cattivelli, H. Garudadri","doi":"10.1109/BSN.2009.35","DOIUrl":null,"url":null,"abstract":"We study the problem of noninvasively estimating Blood Pressure (BP) without using a cuff, which is attractive for continuous monitoring of BP over Body Area Networks. It has been shown that the Pulse Arrival Time (PAT) measured as the delay between the ECG peak and a point in the finger PPG waveform can be used to estimate systolic and diastolic BP. Our aim is to evaluate the performance of such a method using the available MIMIC database, while at the same time improve the performance of existing techniques. We propose an algorithm to estimate BP from a combination of PAT and heart rate, showing improvement over PAT alone. We also show how the method achieves recalibration using an RLS adaptive algorithm. Finally, we address the use case of ECG and PPG sensors wirelessly communicating to an aggregator and study the effect of skew and jitter on BP estimation.","PeriodicalId":269861,"journal":{"name":"2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"145","resultStr":"{\"title\":\"Noninvasive Cuffless Estimation of Blood Pressure from Pulse Arrival Time and Heart Rate with Adaptive Calibration\",\"authors\":\"F. Cattivelli, H. Garudadri\",\"doi\":\"10.1109/BSN.2009.35\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We study the problem of noninvasively estimating Blood Pressure (BP) without using a cuff, which is attractive for continuous monitoring of BP over Body Area Networks. It has been shown that the Pulse Arrival Time (PAT) measured as the delay between the ECG peak and a point in the finger PPG waveform can be used to estimate systolic and diastolic BP. Our aim is to evaluate the performance of such a method using the available MIMIC database, while at the same time improve the performance of existing techniques. We propose an algorithm to estimate BP from a combination of PAT and heart rate, showing improvement over PAT alone. We also show how the method achieves recalibration using an RLS adaptive algorithm. Finally, we address the use case of ECG and PPG sensors wirelessly communicating to an aggregator and study the effect of skew and jitter on BP estimation.\",\"PeriodicalId\":269861,\"journal\":{\"name\":\"2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"145\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BSN.2009.35\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BSN.2009.35","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 145

摘要

我们研究了不使用袖带的无创血压估算问题,这对于通过身体区域网络连续监测血压具有吸引力。研究表明,脉冲到达时间(PAT)作为心电图峰值与手指PPG波形中某一点之间的延迟,可以用来估计收缩压和舒张压。我们的目标是使用可用的MIMIC数据库来评估这种方法的性能,同时改进现有技术的性能。我们提出了一种从PAT和心率组合估计BP的算法,显示出比单独PAT的改进。我们还展示了该方法如何使用RLS自适应算法实现重新校准。最后,我们讨论了ECG和PPG传感器与聚合器无线通信的用例,并研究了倾斜和抖动对BP估计的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Noninvasive Cuffless Estimation of Blood Pressure from Pulse Arrival Time and Heart Rate with Adaptive Calibration
We study the problem of noninvasively estimating Blood Pressure (BP) without using a cuff, which is attractive for continuous monitoring of BP over Body Area Networks. It has been shown that the Pulse Arrival Time (PAT) measured as the delay between the ECG peak and a point in the finger PPG waveform can be used to estimate systolic and diastolic BP. Our aim is to evaluate the performance of such a method using the available MIMIC database, while at the same time improve the performance of existing techniques. We propose an algorithm to estimate BP from a combination of PAT and heart rate, showing improvement over PAT alone. We also show how the method achieves recalibration using an RLS adaptive algorithm. Finally, we address the use case of ECG and PPG sensors wirelessly communicating to an aggregator and study the effect of skew and jitter on BP estimation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A h-Shirt-Based Body Sensor Network for Cuffless Calibration and Estimation of Arterial Blood Pressure Key Considerations and Experience Using the Ultra Low Power Sensium Platform in Body Sensor Networks Technologies for an Autonomous Wireless Home Healthcare System Transitional Activity Recognition with Manifold Embedding Wireless Propagation and Coexistence of Medical Body Sensor Networks for Ambulatory Patient Monitoring
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1