Topcon DL-101C数字电平

J. M. Rüeger
{"title":"Topcon DL-101C数字电平","authors":"J. M. Rüeger","doi":"10.1080/00050354.2000.10558816","DOIUrl":null,"url":null,"abstract":"Even though the Topcon digital levels have been on the market since 1994, very little has been reported on the working principle of these instruments and on the results achieved with them. This paper discusses the operating principle of the Topcon digital level DL-101C and explains how the staff reading and the sighting distance are derived from the image of the coded staff that is ‘seen’ by the linear sensor of the instrument. Experiences gained with the instrument at UNSW are reported and those of other researchers are summarised. In routine precision digital levelling tests carried out by students at UNSW,·the one-kilometre double-run precision was found to be ±0.22 mm when using specialised measuring and processing procedures. Also at UNSW, the temperature effect on the lines of sight of two DL-101C digital levels was determined as +0. 57”/C and +0.42”/C and the vertical shift as +6 μm/C. Cyclic errors of maximum amplitudes between 12 μm and 39 μm were found in the staff readings of four DL-101C digital levels.","PeriodicalId":119818,"journal":{"name":"Australian Surveyor","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2000-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"The Topcon DL-101C Digital Level\",\"authors\":\"J. M. Rüeger\",\"doi\":\"10.1080/00050354.2000.10558816\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Even though the Topcon digital levels have been on the market since 1994, very little has been reported on the working principle of these instruments and on the results achieved with them. This paper discusses the operating principle of the Topcon digital level DL-101C and explains how the staff reading and the sighting distance are derived from the image of the coded staff that is ‘seen’ by the linear sensor of the instrument. Experiences gained with the instrument at UNSW are reported and those of other researchers are summarised. In routine precision digital levelling tests carried out by students at UNSW,·the one-kilometre double-run precision was found to be ±0.22 mm when using specialised measuring and processing procedures. Also at UNSW, the temperature effect on the lines of sight of two DL-101C digital levels was determined as +0. 57”/C and +0.42”/C and the vertical shift as +6 μm/C. Cyclic errors of maximum amplitudes between 12 μm and 39 μm were found in the staff readings of four DL-101C digital levels.\",\"PeriodicalId\":119818,\"journal\":{\"name\":\"Australian Surveyor\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Australian Surveyor\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00050354.2000.10558816\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australian Surveyor","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00050354.2000.10558816","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

尽管自1994年以来,Topcon数字电平已经上市,但很少有关于这些仪器的工作原理和使用它们取得的结果的报道。本文讨论了Topcon数字水准仪DL-101C的工作原理,并解释了如何从仪器的线性传感器“看到”的编码水准仪图像中导出水准仪读数和瞄准距离。报告了新南威尔士大学使用该仪器获得的经验,并总结了其他研究人员的经验。在新南威尔士大学学生进行的常规精密数字调平测试中,在使用专门的测量和处理程序时,发现一公里双跑精度为±0.22 mm。同样在新南威尔士大学,两个DL-101C数字水平仪的温度对视线的影响被确定为+0。57 " /C和+0.42 " /C,垂直位移+6 μm/C。DL-101C 4个数字液位计的工作人员读数的最大周期误差在12 μm ~ 39 μm之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Topcon DL-101C Digital Level
Even though the Topcon digital levels have been on the market since 1994, very little has been reported on the working principle of these instruments and on the results achieved with them. This paper discusses the operating principle of the Topcon digital level DL-101C and explains how the staff reading and the sighting distance are derived from the image of the coded staff that is ‘seen’ by the linear sensor of the instrument. Experiences gained with the instrument at UNSW are reported and those of other researchers are summarised. In routine precision digital levelling tests carried out by students at UNSW,·the one-kilometre double-run precision was found to be ±0.22 mm when using specialised measuring and processing procedures. Also at UNSW, the temperature effect on the lines of sight of two DL-101C digital levels was determined as +0. 57”/C and +0.42”/C and the vertical shift as +6 μm/C. Cyclic errors of maximum amplitudes between 12 μm and 39 μm were found in the staff readings of four DL-101C digital levels.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Cadastral Systems within Australia Press Release The Need to Provide for Boundary Adjustments in a Registered Title Land System The Cost of Land Registration: a Case Study of Cost Efficiency in Namibia Hydrographic News
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1