一种多电机闭环驱动系统定子匝间故障检测新方法

Siwei Cheng, T. Habetler
{"title":"一种多电机闭环驱动系统定子匝间故障检测新方法","authors":"Siwei Cheng, T. Habetler","doi":"10.1109/DEMPED.2009.5292796","DOIUrl":null,"url":null,"abstract":"Multiple motors connected to a single closed-loop inverter drive is a common type of drive topology which has wide application in steel processing industry, electric railway systems and electric vehicles. But condition monitoring for this type of drive configuration remains largely unexplored. This paper proposes a new method to detect the stator turn-to-turn fault in a multiple-motor drive system. The method achieves very high detecting sensitivity yet remains easy to implement by utilizing the characteristics of current regulators in the motor controller. Experimental results show that the method can reliably detect a short circuit of 1 turn out of 216 turns per phase on two 5-hp, shaft-coupled induction machines. Although originally developed for multiple-motor drives, the detection scheme can be directly applied to most of normal closed-loop induction motor drive.","PeriodicalId":405777,"journal":{"name":"2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"A new method to detect stator turn-to-turn faults in a closed-loop multiple-motor drive system\",\"authors\":\"Siwei Cheng, T. Habetler\",\"doi\":\"10.1109/DEMPED.2009.5292796\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multiple motors connected to a single closed-loop inverter drive is a common type of drive topology which has wide application in steel processing industry, electric railway systems and electric vehicles. But condition monitoring for this type of drive configuration remains largely unexplored. This paper proposes a new method to detect the stator turn-to-turn fault in a multiple-motor drive system. The method achieves very high detecting sensitivity yet remains easy to implement by utilizing the characteristics of current regulators in the motor controller. Experimental results show that the method can reliably detect a short circuit of 1 turn out of 216 turns per phase on two 5-hp, shaft-coupled induction machines. Although originally developed for multiple-motor drives, the detection scheme can be directly applied to most of normal closed-loop induction motor drive.\",\"PeriodicalId\":405777,\"journal\":{\"name\":\"2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEMPED.2009.5292796\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEMPED.2009.5292796","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

多个电机连接到一个闭环逆变驱动器是一种常见的驱动拓扑,在钢铁加工工业、电气化铁路系统和电动汽车中有着广泛的应用。但是这种类型的驱动配置的状态监测在很大程度上仍然是未知的。提出了一种检测多电机驱动系统定子匝间故障的新方法。该方法利用电机控制器中电流调节器的特性,实现了非常高的检测灵敏度,但仍然易于实现。实验结果表明,该方法可以可靠地检测出两台5马力轴联感应电机每相216转中有1转的短路。虽然最初是为多电机驱动开发的,但该检测方案可以直接应用于大多数普通闭环感应电机驱动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A new method to detect stator turn-to-turn faults in a closed-loop multiple-motor drive system
Multiple motors connected to a single closed-loop inverter drive is a common type of drive topology which has wide application in steel processing industry, electric railway systems and electric vehicles. But condition monitoring for this type of drive configuration remains largely unexplored. This paper proposes a new method to detect the stator turn-to-turn fault in a multiple-motor drive system. The method achieves very high detecting sensitivity yet remains easy to implement by utilizing the characteristics of current regulators in the motor controller. Experimental results show that the method can reliably detect a short circuit of 1 turn out of 216 turns per phase on two 5-hp, shaft-coupled induction machines. Although originally developed for multiple-motor drives, the detection scheme can be directly applied to most of normal closed-loop induction motor drive.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative study of two modelling implementation methods of a wound-rotor induction machine: Simulation, fault diagnosis and validation Fault diagnosis of linear bearings in brushless AC linear motors Detection of insulation faults on disc-type winding transformers by means of leakage flux analysis Narrowband angle modulations in induction motor complex current vectors Thermal modeling and real time overload capacity prediction of overhead power lines
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1