经皮神经电刺激缓解疼痛

S. Smaoui, H. Ghariani, A. Hamida, C. Mhiri, I. Feki
{"title":"经皮神经电刺激缓解疼痛","authors":"S. Smaoui, H. Ghariani, A. Hamida, C. Mhiri, I. Feki","doi":"10.1109/ISCCSP.2004.1296273","DOIUrl":null,"url":null,"abstract":"In this article, we propose to study and to conceive a programmable signal generator allowing inhibition of certain types of pain. This system would be provided with an electrode which could be applied in the periphery level of the patient's spinal cord in order to excite the nervous zone responsible for pain transmission. The conceived system would be commanded with variable voltages and piloted by a dedicated microcontroller. This would allow us to have different possibilities in conceiving various shapes of stimulating waves. The purpose is to offer flexibility during clinical adjustments especially when programming the various parameters of electrical stimuli. A PC connection was also provided in order to visualize and to adjust stimulating wave parameters. Our system could be then considered as an original one since it is enhanced by flexibility and maneuverability during clinical trials.","PeriodicalId":146713,"journal":{"name":"First International Symposium on Control, Communications and Signal Processing, 2004.","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Transcutaneous electrical nerve stimulation for pain relief\",\"authors\":\"S. Smaoui, H. Ghariani, A. Hamida, C. Mhiri, I. Feki\",\"doi\":\"10.1109/ISCCSP.2004.1296273\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this article, we propose to study and to conceive a programmable signal generator allowing inhibition of certain types of pain. This system would be provided with an electrode which could be applied in the periphery level of the patient's spinal cord in order to excite the nervous zone responsible for pain transmission. The conceived system would be commanded with variable voltages and piloted by a dedicated microcontroller. This would allow us to have different possibilities in conceiving various shapes of stimulating waves. The purpose is to offer flexibility during clinical adjustments especially when programming the various parameters of electrical stimuli. A PC connection was also provided in order to visualize and to adjust stimulating wave parameters. Our system could be then considered as an original one since it is enhanced by flexibility and maneuverability during clinical trials.\",\"PeriodicalId\":146713,\"journal\":{\"name\":\"First International Symposium on Control, Communications and Signal Processing, 2004.\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"First International Symposium on Control, Communications and Signal Processing, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISCCSP.2004.1296273\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"First International Symposium on Control, Communications and Signal Processing, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISCCSP.2004.1296273","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在这篇文章中,我们建议研究和设想一个可编程的信号发生器,允许抑制某些类型的疼痛。该系统将配备一个电极,该电极可以应用于患者脊髓的外周水平,以激发负责疼痛传递的神经区。设想的系统将由一个专用的微控制器控制和控制可变电压。这将使我们在构思各种形状的刺激波时有不同的可能性。目的是在临床调整期间提供灵活性,特别是在编程电刺激的各种参数时。为了可视化和调整刺激波参数,还提供了PC连接。我们的系统可以被认为是一个原始的系统,因为它在临床试验中增强了灵活性和可操作性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Transcutaneous electrical nerve stimulation for pain relief
In this article, we propose to study and to conceive a programmable signal generator allowing inhibition of certain types of pain. This system would be provided with an electrode which could be applied in the periphery level of the patient's spinal cord in order to excite the nervous zone responsible for pain transmission. The conceived system would be commanded with variable voltages and piloted by a dedicated microcontroller. This would allow us to have different possibilities in conceiving various shapes of stimulating waves. The purpose is to offer flexibility during clinical adjustments especially when programming the various parameters of electrical stimuli. A PC connection was also provided in order to visualize and to adjust stimulating wave parameters. Our system could be then considered as an original one since it is enhanced by flexibility and maneuverability during clinical trials.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Complexity reduction of high-speed FIR filters using micro-genetic algorithm PAPR analysis and reduction in WPDM systems On cross-layer adaptivity and optimization for multimedia CDMA mobile wireless networks Absolute effects of aggregation of self-similar traffic on quality of service parameters Scanned maps processing using wavelet domain hidden Markov models
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1