风电场无功辅助服务

N. Ullah, Kankar Bhattacharya, T. Thiringer
{"title":"风电场无功辅助服务","authors":"N. Ullah, Kankar Bhattacharya, T. Thiringer","doi":"10.1109/EPC.2007.4520393","DOIUrl":null,"url":null,"abstract":"Reactive power/voltage control support, temporary primary frequency control support, power oscillation damping support are some of the functions that can be provided by modern wind farms (WFs) equipped with variable speed wind turbines (VSWT) with power electronic converters. This paper examines the possibility of WFs providing reactive power support to the grid system as part of ancillary service provisions. Detailed analysis of the WF capability curve is carried out, and a reactive power cost model is developed for wind turbine generators that can help the market operator or the independent system operator (ISO) in managing the system and the grid efficiently. The Cigre-32 bus test system is used to demonstrate a case study showing a 24-hour calculation of 10-minute average system operation cost considering the incoming wind energy.","PeriodicalId":196861,"journal":{"name":"2007 IEEE Canada Electrical Power Conference","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Reactive Power Ancillary Service from Wind Farms\",\"authors\":\"N. Ullah, Kankar Bhattacharya, T. Thiringer\",\"doi\":\"10.1109/EPC.2007.4520393\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reactive power/voltage control support, temporary primary frequency control support, power oscillation damping support are some of the functions that can be provided by modern wind farms (WFs) equipped with variable speed wind turbines (VSWT) with power electronic converters. This paper examines the possibility of WFs providing reactive power support to the grid system as part of ancillary service provisions. Detailed analysis of the WF capability curve is carried out, and a reactive power cost model is developed for wind turbine generators that can help the market operator or the independent system operator (ISO) in managing the system and the grid efficiently. The Cigre-32 bus test system is used to demonstrate a case study showing a 24-hour calculation of 10-minute average system operation cost considering the incoming wind energy.\",\"PeriodicalId\":196861,\"journal\":{\"name\":\"2007 IEEE Canada Electrical Power Conference\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Canada Electrical Power Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPC.2007.4520393\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Canada Electrical Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPC.2007.4520393","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

无功功率/电压控制支持,临时一次频率控制支持,功率振荡阻尼支持是配备变速风力涡轮机(VSWT)的现代风电场(wf)可以提供的一些功能。本文考察了WFs作为辅助服务条款的一部分向电网系统提供无功支持的可能性。在对WF能力曲线进行详细分析的基础上,建立了风电机组无功成本模型,该模型可以帮助市场运营商或独立系统运营商(ISO)有效地管理系统和电网。Cigre-32总线测试系统用于演示一个案例研究,该案例研究显示了考虑进入风能的10分钟平均系统运行成本的24小时计算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reactive Power Ancillary Service from Wind Farms
Reactive power/voltage control support, temporary primary frequency control support, power oscillation damping support are some of the functions that can be provided by modern wind farms (WFs) equipped with variable speed wind turbines (VSWT) with power electronic converters. This paper examines the possibility of WFs providing reactive power support to the grid system as part of ancillary service provisions. Detailed analysis of the WF capability curve is carried out, and a reactive power cost model is developed for wind turbine generators that can help the market operator or the independent system operator (ISO) in managing the system and the grid efficiently. The Cigre-32 bus test system is used to demonstrate a case study showing a 24-hour calculation of 10-minute average system operation cost considering the incoming wind energy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Variable Speed Wind Turbines Using Cage Rotor Induction Generators Connected to the Grid Exergy Concept and its Application PMSG Wind Turbine Performance Analysis During Short Circuit Faults Dynamic Voltage Stabilization of Stand-Alone Wind Energy Schemes Analysis of a Hybrid Current Source Converter with Bi-directional Power Flow Capability
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1