一种单级三相交直流变换器的研究与实现

Lung-Sheng Yang, Chia-Ching Lin, E. Chang
{"title":"一种单级三相交直流变换器的研究与实现","authors":"Lung-Sheng Yang, Chia-Ching Lin, E. Chang","doi":"10.1109/ISIE.2012.6237143","DOIUrl":null,"url":null,"abstract":"A single-stage three-phase AC-DC converter is presented in this paper. The front semi-stage of the proposed converter, which is operated in discontinuous conduction mode (DCM), is utilized for power factor correction and the rear semi-stage of the proposed converter, which is operated in continuous conduction mode (CCM) at heavy loads and in DCM at light loads, is employed for step-down voltage conversion. The proposed converter can achieve almost unity power factor, low total harmonic distortion of input current (THDi), and adjustable DC output voltage. The voltage stress across the DC-link capacitor is low. Moreover, the steady-state analyses of voltage gain and the boundary operating condition are discussed. Finally, experimental results are provided to verify theoretical analyses.","PeriodicalId":375971,"journal":{"name":"2009 IEEE 6th International Power Electronics and Motion Control Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Study and implementation of a single-stage three-phase AC-DC converter\",\"authors\":\"Lung-Sheng Yang, Chia-Ching Lin, E. Chang\",\"doi\":\"10.1109/ISIE.2012.6237143\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A single-stage three-phase AC-DC converter is presented in this paper. The front semi-stage of the proposed converter, which is operated in discontinuous conduction mode (DCM), is utilized for power factor correction and the rear semi-stage of the proposed converter, which is operated in continuous conduction mode (CCM) at heavy loads and in DCM at light loads, is employed for step-down voltage conversion. The proposed converter can achieve almost unity power factor, low total harmonic distortion of input current (THDi), and adjustable DC output voltage. The voltage stress across the DC-link capacitor is low. Moreover, the steady-state analyses of voltage gain and the boundary operating condition are discussed. Finally, experimental results are provided to verify theoretical analyses.\",\"PeriodicalId\":375971,\"journal\":{\"name\":\"2009 IEEE 6th International Power Electronics and Motion Control Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE 6th International Power Electronics and Motion Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2012.6237143\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE 6th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2012.6237143","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文介绍了一种单级三相交直流变换器。该变换器的前半级工作在断续导通模式(DCM)下,用于功率因数校正,后半级工作在连续导通模式(CCM)下,在轻负荷下工作在DCM下,用于降压转换。该变换器可以实现几乎统一的功率因数、低的输入电流总谐波失真和可调的直流输出电压。直流链路电容的电压应力很低。此外,还讨论了电压增益的稳态分析和边界工作条件。最后给出了实验结果来验证理论分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study and implementation of a single-stage three-phase AC-DC converter
A single-stage three-phase AC-DC converter is presented in this paper. The front semi-stage of the proposed converter, which is operated in discontinuous conduction mode (DCM), is utilized for power factor correction and the rear semi-stage of the proposed converter, which is operated in continuous conduction mode (CCM) at heavy loads and in DCM at light loads, is employed for step-down voltage conversion. The proposed converter can achieve almost unity power factor, low total harmonic distortion of input current (THDi), and adjustable DC output voltage. The voltage stress across the DC-link capacitor is low. Moreover, the steady-state analyses of voltage gain and the boundary operating condition are discussed. Finally, experimental results are provided to verify theoretical analyses.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Study and implementation of a single-stage three-phase AC-DC converter A resonant gate-drive circuit capable of high-frequency and high-efficiency operation Study of multi-level rectifier in high power system based on a novel virtual flux observer Power control strategy of electronic ballast for Metal Halide Lamps Design of a digital control IC of a current source based on a three-phase controlled rectifier
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1