非理想电网条件下并网电压源变换器的锁相环

Haojie Wang, Hai Sun, Minxiao Han, J. Guerrero
{"title":"非理想电网条件下并网电压源变换器的锁相环","authors":"Haojie Wang, Hai Sun, Minxiao Han, J. Guerrero","doi":"10.1109/ICDCM.2015.7152022","DOIUrl":null,"url":null,"abstract":"It is a normal practice that the DC micro-grid is connected to AC main grid through Grid-connected Voltage Source Converter (G-VSC) for voltage support. Accurate control of DC micro-grid voltage is difficult for G-VSC under unbalanced grid condition as the fundamental positive-sequence component phase information cannot be accurately tracked. Based on analysis of the cause of double-frequency ripple when unbalance exists in main grid, a phase-locked loop (PLL) detection technique is proposed. Under the conditions of unsymmetrical system voltage, varying system frequency, single-phase system and distorted system voltage the proposed PLL can accurately detect the fundamental positive-sequence component of grid voltage thus accurate control of DC micro-grid voltage can be realized.","PeriodicalId":110320,"journal":{"name":"2015 IEEE First International Conference on DC Microgrids (ICDCM)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Phase-lock loop of Grid-connected Voltage Source Converter under non-ideal grid condition\",\"authors\":\"Haojie Wang, Hai Sun, Minxiao Han, J. Guerrero\",\"doi\":\"10.1109/ICDCM.2015.7152022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is a normal practice that the DC micro-grid is connected to AC main grid through Grid-connected Voltage Source Converter (G-VSC) for voltage support. Accurate control of DC micro-grid voltage is difficult for G-VSC under unbalanced grid condition as the fundamental positive-sequence component phase information cannot be accurately tracked. Based on analysis of the cause of double-frequency ripple when unbalance exists in main grid, a phase-locked loop (PLL) detection technique is proposed. Under the conditions of unsymmetrical system voltage, varying system frequency, single-phase system and distorted system voltage the proposed PLL can accurately detect the fundamental positive-sequence component of grid voltage thus accurate control of DC micro-grid voltage can be realized.\",\"PeriodicalId\":110320,\"journal\":{\"name\":\"2015 IEEE First International Conference on DC Microgrids (ICDCM)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE First International Conference on DC Microgrids (ICDCM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICDCM.2015.7152022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE First International Conference on DC Microgrids (ICDCM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDCM.2015.7152022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

直流微电网通过并网电压源变换器(G-VSC)接入交流主电网进行电压支撑是一种惯例。在电网不平衡条件下,由于不能准确跟踪基态正序分量的相位信息,使得G-VSC难以精确控制直流微电网电压。在分析主电网存在不平衡时产生双频纹波的原因的基础上,提出了一种锁相环检测技术。在系统电压不对称、系统频率变化、系统单相和系统电压畸变等情况下,该锁相环能够准确检测出电网电压的基态正序分量,从而实现对直流微电网电压的精确控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Phase-lock loop of Grid-connected Voltage Source Converter under non-ideal grid condition
It is a normal practice that the DC micro-grid is connected to AC main grid through Grid-connected Voltage Source Converter (G-VSC) for voltage support. Accurate control of DC micro-grid voltage is difficult for G-VSC under unbalanced grid condition as the fundamental positive-sequence component phase information cannot be accurately tracked. Based on analysis of the cause of double-frequency ripple when unbalance exists in main grid, a phase-locked loop (PLL) detection technique is proposed. Under the conditions of unsymmetrical system voltage, varying system frequency, single-phase system and distorted system voltage the proposed PLL can accurately detect the fundamental positive-sequence component of grid voltage thus accurate control of DC micro-grid voltage can be realized.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Supercapacitor-based DC-DC converter technique for DC-microgrids with UPS capability Modelling and measuring complex impedances of power electronic converters for stability assessment of low-voltage DC-grids Two-level control for fast electrical vehicle charging stations with multi flywheel energy storage system Technological and deployment challenges and user-response to uninterrupted DC (UDC) deployment in Indian homes Analysis of emerging technology for DC-enabled smart homes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1