B. K. Hall, J. Appel, G. Cardoso, D. Christian, J. Hoff, S. Kwan, A. Mekkaoui, R. Yarema, S. Zimmermann
{"title":"费米实验室高数据速率BTeV像素探测器读出技术的发展","authors":"B. K. Hall, J. Appel, G. Cardoso, D. Christian, J. Hoff, S. Kwan, A. Mekkaoui, R. Yarema, S. Zimmermann","doi":"10.1109/NSSMIC.2001.1008416","DOIUrl":null,"url":null,"abstract":"The pixel detector for the BTeV experiment at Fermilab provides digitized data from approximately 22 million silicon pixel channels. Portions of the detector are six millimeters from the beam providing a substantial hit rate and high radiation dose. The pixel detector data will be employed by the lowest level trigger system for track reconstruction every beam crossing. These requirements impose a considerable constraint on the readout scheme. This paper presents a readout technique that provides the bandwidth that is adequate for high hit rates, minimizes the number of radiation hard components, and satisfies all other design constraints.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Development of a readout technique for the high data rate BTeV pixel detector at Fermilab\",\"authors\":\"B. K. Hall, J. Appel, G. Cardoso, D. Christian, J. Hoff, S. Kwan, A. Mekkaoui, R. Yarema, S. Zimmermann\",\"doi\":\"10.1109/NSSMIC.2001.1008416\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The pixel detector for the BTeV experiment at Fermilab provides digitized data from approximately 22 million silicon pixel channels. Portions of the detector are six millimeters from the beam providing a substantial hit rate and high radiation dose. The pixel detector data will be employed by the lowest level trigger system for track reconstruction every beam crossing. These requirements impose a considerable constraint on the readout scheme. This paper presents a readout technique that provides the bandwidth that is adequate for high hit rates, minimizes the number of radiation hard components, and satisfies all other design constraints.\",\"PeriodicalId\":159123,\"journal\":{\"name\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2001.1008416\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1008416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of a readout technique for the high data rate BTeV pixel detector at Fermilab
The pixel detector for the BTeV experiment at Fermilab provides digitized data from approximately 22 million silicon pixel channels. Portions of the detector are six millimeters from the beam providing a substantial hit rate and high radiation dose. The pixel detector data will be employed by the lowest level trigger system for track reconstruction every beam crossing. These requirements impose a considerable constraint on the readout scheme. This paper presents a readout technique that provides the bandwidth that is adequate for high hit rates, minimizes the number of radiation hard components, and satisfies all other design constraints.