R. Sierra, J. Alcalá, V. Cárdenas, J. Perez-Ramirez, A. Rivera
{"title":"不平衡电压跌落下BTB变换器的性能评价","authors":"R. Sierra, J. Alcalá, V. Cárdenas, J. Perez-Ramirez, A. Rivera","doi":"10.1109/ICEEE.2012.6421162","DOIUrl":null,"url":null,"abstract":"In this work, a control structure to maintain the power flow transference in renewable energy systems based on wind turbines operating under unbalanced voltage conditions is presented. In the proposed scheme, the Back-to-Back (BTB) converter preserves the electrical cogeneration under the occurrence of voltage sags type B, C and D in three-phase systems. The control modeling is developed in the dq reference frame and two control schemes are proposed to control the BTB converter. A per-phase analysis at the interconnected grid side is considered; on the other hand, for the load side, a three-phase analysis is established. The effectiveness of the BTB converter to compensate voltage sags is shown through simulation and experimental results.","PeriodicalId":162368,"journal":{"name":"2012 9th International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE)","volume":"47 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Evaluating the performance of the BTB converter under unbalanced voltage sags\",\"authors\":\"R. Sierra, J. Alcalá, V. Cárdenas, J. Perez-Ramirez, A. Rivera\",\"doi\":\"10.1109/ICEEE.2012.6421162\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, a control structure to maintain the power flow transference in renewable energy systems based on wind turbines operating under unbalanced voltage conditions is presented. In the proposed scheme, the Back-to-Back (BTB) converter preserves the electrical cogeneration under the occurrence of voltage sags type B, C and D in three-phase systems. The control modeling is developed in the dq reference frame and two control schemes are proposed to control the BTB converter. A per-phase analysis at the interconnected grid side is considered; on the other hand, for the load side, a three-phase analysis is established. The effectiveness of the BTB converter to compensate voltage sags is shown through simulation and experimental results.\",\"PeriodicalId\":162368,\"journal\":{\"name\":\"2012 9th International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE)\",\"volume\":\"47 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 9th International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEEE.2012.6421162\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 9th International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEEE.2012.6421162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluating the performance of the BTB converter under unbalanced voltage sags
In this work, a control structure to maintain the power flow transference in renewable energy systems based on wind turbines operating under unbalanced voltage conditions is presented. In the proposed scheme, the Back-to-Back (BTB) converter preserves the electrical cogeneration under the occurrence of voltage sags type B, C and D in three-phase systems. The control modeling is developed in the dq reference frame and two control schemes are proposed to control the BTB converter. A per-phase analysis at the interconnected grid side is considered; on the other hand, for the load side, a three-phase analysis is established. The effectiveness of the BTB converter to compensate voltage sags is shown through simulation and experimental results.