Z. Shams, T. Javed, A. Zubair, M. Waqas, S. Ali, Anusha Ahmed
{"title":"煤气燃烧器厨房的一氧化碳浓度,卡拉奇,巴基斯坦","authors":"Z. Shams, T. Javed, A. Zubair, M. Waqas, S. Ali, Anusha Ahmed","doi":"10.52763/pjsir.phys.sci.65.1.2022.25.32","DOIUrl":null,"url":null,"abstract":"In this study, gas-fired kitchens of 54 bungalows and 25 apartments were studied using stationary indoor carbon monoxide (CO) monitoring. The levels of CO were measured in each kitchen for a period of 24 h with a 1 min resolution using data logger EL-USB-CO300. Hourly, 8 h and 24 h, CO means for all the kitchens were calculated. Hourly and 24 h CO means of kitchens for bungalows were 3.72±6.26 ppm and 3.72±3.16 ppm, respectively, while those apartments have 3.74±6.96 ppm and 3.74±2.17 ppm, respectively. 8 h CO means of night, day and evening in the kitchens of bungalows were 2.62±3.22 ppm, 4.85±4.66 ppm and 3.53±3.30 ppm, respectively, while in apartments 2.13±2.02 ppm, 3.79±3.86 ppm and 5.29±4.17 ppm. The mean difference between the 8 h CO concentrations during the evening in bungalows and apartments was 1.76±0.87 ppm (P<0.01). 20% of kitchens apartment and 16.67% of bungalows which exceeded the WHO guidelines for daily exposure limit.","PeriodicalId":228754,"journal":{"name":"Pakistan Journal of Scientific & Industrial Research Series A: Physical Sciences","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Carbon Monoxide Concentrations in Kitchens of Gas-fired Burners, Karachi, Pakistan\",\"authors\":\"Z. Shams, T. Javed, A. Zubair, M. Waqas, S. Ali, Anusha Ahmed\",\"doi\":\"10.52763/pjsir.phys.sci.65.1.2022.25.32\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, gas-fired kitchens of 54 bungalows and 25 apartments were studied using stationary indoor carbon monoxide (CO) monitoring. The levels of CO were measured in each kitchen for a period of 24 h with a 1 min resolution using data logger EL-USB-CO300. Hourly, 8 h and 24 h, CO means for all the kitchens were calculated. Hourly and 24 h CO means of kitchens for bungalows were 3.72±6.26 ppm and 3.72±3.16 ppm, respectively, while those apartments have 3.74±6.96 ppm and 3.74±2.17 ppm, respectively. 8 h CO means of night, day and evening in the kitchens of bungalows were 2.62±3.22 ppm, 4.85±4.66 ppm and 3.53±3.30 ppm, respectively, while in apartments 2.13±2.02 ppm, 3.79±3.86 ppm and 5.29±4.17 ppm. The mean difference between the 8 h CO concentrations during the evening in bungalows and apartments was 1.76±0.87 ppm (P<0.01). 20% of kitchens apartment and 16.67% of bungalows which exceeded the WHO guidelines for daily exposure limit.\",\"PeriodicalId\":228754,\"journal\":{\"name\":\"Pakistan Journal of Scientific & Industrial Research Series A: Physical Sciences\",\"volume\":\"53 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pakistan Journal of Scientific & Industrial Research Series A: Physical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52763/pjsir.phys.sci.65.1.2022.25.32\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pakistan Journal of Scientific & Industrial Research Series A: Physical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52763/pjsir.phys.sci.65.1.2022.25.32","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
在这项研究中,使用固定式室内一氧化碳(CO)监测仪对54间平房和25间公寓的燃气厨房进行了研究。使用EL-USB-CO300数据记录仪以1分钟分辨率测量每个厨房内24小时的CO水平。每小时,8小时和24小时,计算所有厨房的CO平均值。平房厨房每小时和24小时的CO平均值分别为3.72±6.26 ppm和3.72±3.16 ppm,而公寓厨房的CO平均值分别为3.74±6.96 ppm和3.74±2.17 ppm。平房厨房8 h CO均值夜间、白天和晚上分别为2.62±3.22 ppm、4.85±4.66 ppm和3.53±3.30 ppm,公寓厨房8 h CO均值分别为2.13±2.02 ppm、3.79±3.86 ppm和5.29±4.17 ppm。平房与公寓夜间8 h CO浓度的平均差异为1.76±0.87 ppm (P<0.01)。20%的厨房公寓和16.67%的平房超过了世界卫生组织的每日接触限值。
Carbon Monoxide Concentrations in Kitchens of Gas-fired Burners, Karachi, Pakistan
In this study, gas-fired kitchens of 54 bungalows and 25 apartments were studied using stationary indoor carbon monoxide (CO) monitoring. The levels of CO were measured in each kitchen for a period of 24 h with a 1 min resolution using data logger EL-USB-CO300. Hourly, 8 h and 24 h, CO means for all the kitchens were calculated. Hourly and 24 h CO means of kitchens for bungalows were 3.72±6.26 ppm and 3.72±3.16 ppm, respectively, while those apartments have 3.74±6.96 ppm and 3.74±2.17 ppm, respectively. 8 h CO means of night, day and evening in the kitchens of bungalows were 2.62±3.22 ppm, 4.85±4.66 ppm and 3.53±3.30 ppm, respectively, while in apartments 2.13±2.02 ppm, 3.79±3.86 ppm and 5.29±4.17 ppm. The mean difference between the 8 h CO concentrations during the evening in bungalows and apartments was 1.76±0.87 ppm (P<0.01). 20% of kitchens apartment and 16.67% of bungalows which exceeded the WHO guidelines for daily exposure limit.