某三级医院急诊室3个月~ 5岁社区获得性肺炎患儿低氧血症各种检测方法的比较及其与临床特征的相关性

Francesca Mae T. Pantig, S. Gatchalian
{"title":"某三级医院急诊室3个月~ 5岁社区获得性肺炎患儿低氧血症各种检测方法的比较及其与临床特征的相关性","authors":"Francesca Mae T. Pantig, S. Gatchalian","doi":"10.56964/pidspj20192001005","DOIUrl":null,"url":null,"abstract":"Introduction: Pulse oximetry is frequently utilized as a rapid, non-invasive, point-of-care alternative to arterial blood gas analysis in measuring oxygen saturation of children with pneumonia. Objectives: To compare portable fingertip pulse oximetry saturation (SpO2PF), handheld pulse oximetry saturation (SpO2H) and arterial oxygen saturation (SaO2) in detection of hypoxemia, and correlate hypoxemia with clinical features in children with pneumonia. Methodology: This was a prospective, observational, cross-sectional study involving patients 3 months to 5 years old with pneumonia. Oxygen saturation was measured using a portable fingertip pulse oximeter, a handheld pulse oximeter, and arterial blood gas analysis. Results: Eighty-six children were included. SpO2 PF underestimated oxygen levels by 0.126% (95% CI -0.240 to 0.491), while SpO2H underestimated it by 0.323% (95% CI -0.075 to 0.721). Between portable and handheld readings, the mean difference was 0.198% (95% CI -0.089 to 0.484). Across the three methods, limits of agreement ranged from -3.388 to +4.035%. There was no statistically significant difference in variance among the three measurements. Children with tachypnea (cOR 2.623, 95% CI 1.06 – 6.48, p = 0.037), difficulty breathing (cOR 6.316, 95% CI 1.96 – 20.34, p = 0.002), and subcostal retractions (cOR 2.842, 95% CI 1.05 to 7.69, p = 0.040) were more likely to have hypoxemia. Conclusion: Pulse oximetry closely correlates with arterial blood gas analysis within acceptable limits of agreement and with no significant differences in variance among measurements. Difficulty breathing, tachypnea and subcostal retractions were significantly more likely to be observed in hypoxemic children.","PeriodicalId":117545,"journal":{"name":"Pediatric Infectious Disease Society of the Philippines Journal","volume":"16 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Various Methods of Detection of Hypoxemia and Correlation of Hypoxemia with Clinical Features among Pediatric Patients 3 Months to 5 Years Old with Community-Acquired Pneumonia at a Tertiary Hospital Emergency Room\",\"authors\":\"Francesca Mae T. Pantig, S. Gatchalian\",\"doi\":\"10.56964/pidspj20192001005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Pulse oximetry is frequently utilized as a rapid, non-invasive, point-of-care alternative to arterial blood gas analysis in measuring oxygen saturation of children with pneumonia. Objectives: To compare portable fingertip pulse oximetry saturation (SpO2PF), handheld pulse oximetry saturation (SpO2H) and arterial oxygen saturation (SaO2) in detection of hypoxemia, and correlate hypoxemia with clinical features in children with pneumonia. Methodology: This was a prospective, observational, cross-sectional study involving patients 3 months to 5 years old with pneumonia. Oxygen saturation was measured using a portable fingertip pulse oximeter, a handheld pulse oximeter, and arterial blood gas analysis. Results: Eighty-six children were included. SpO2 PF underestimated oxygen levels by 0.126% (95% CI -0.240 to 0.491), while SpO2H underestimated it by 0.323% (95% CI -0.075 to 0.721). Between portable and handheld readings, the mean difference was 0.198% (95% CI -0.089 to 0.484). Across the three methods, limits of agreement ranged from -3.388 to +4.035%. There was no statistically significant difference in variance among the three measurements. Children with tachypnea (cOR 2.623, 95% CI 1.06 – 6.48, p = 0.037), difficulty breathing (cOR 6.316, 95% CI 1.96 – 20.34, p = 0.002), and subcostal retractions (cOR 2.842, 95% CI 1.05 to 7.69, p = 0.040) were more likely to have hypoxemia. Conclusion: Pulse oximetry closely correlates with arterial blood gas analysis within acceptable limits of agreement and with no significant differences in variance among measurements. Difficulty breathing, tachypnea and subcostal retractions were significantly more likely to be observed in hypoxemic children.\",\"PeriodicalId\":117545,\"journal\":{\"name\":\"Pediatric Infectious Disease Society of the Philippines Journal\",\"volume\":\"16 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric Infectious Disease Society of the Philippines Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.56964/pidspj20192001005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Infectious Disease Society of the Philippines Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56964/pidspj20192001005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

简介:脉搏血氧仪经常被用作一种快速、无创、即时的替代动脉血气分析的方法来测量肺炎患儿的血氧饱和度。目的:比较便携式指尖脉搏血氧饱和度(SpO2PF)、手持式脉搏血氧饱和度(SpO2H)和动脉血氧饱和度(SaO2)对低氧血症的检测效果,并将低氧血症与肺炎患儿的临床特征联系起来。方法:这是一项前瞻性、观察性、横断面研究,涉及3个月至5岁的肺炎患者。使用便携式指尖脉搏血氧仪、手持式脉搏血氧仪和动脉血气分析测量血氧饱和度。结果:共纳入86例儿童。SpO2 PF低估了氧含量0.126% (95% CI -0.240至0.491),而SpO2H低估了氧含量0.323% (95% CI -0.075至0.721)。在便携式和手持读数之间,平均差异为0.198% (95% CI -0.089至0.484)。在三种方法中,一致性的限制范围从-3.388到+4.035%。三种测量方法的方差差异无统计学意义。呼吸急促(cOR 2.623, 95% CI 1.06 - 6.48, p = 0.037)、呼吸困难(cOR 6.316, 95% CI 1.96 - 20.34, p = 0.002)和肋下回缩(cOR 2.842, 95% CI 1.05 - 7.69, p = 0.040)患儿更容易出现低氧血症。结论:脉搏血氧测定与动脉血气分析在可接受的一致性范围内密切相关,且测量值之间的方差无显著差异。呼吸困难、呼吸急促和肋下肌回缩在低氧儿童中更容易出现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of Various Methods of Detection of Hypoxemia and Correlation of Hypoxemia with Clinical Features among Pediatric Patients 3 Months to 5 Years Old with Community-Acquired Pneumonia at a Tertiary Hospital Emergency Room
Introduction: Pulse oximetry is frequently utilized as a rapid, non-invasive, point-of-care alternative to arterial blood gas analysis in measuring oxygen saturation of children with pneumonia. Objectives: To compare portable fingertip pulse oximetry saturation (SpO2PF), handheld pulse oximetry saturation (SpO2H) and arterial oxygen saturation (SaO2) in detection of hypoxemia, and correlate hypoxemia with clinical features in children with pneumonia. Methodology: This was a prospective, observational, cross-sectional study involving patients 3 months to 5 years old with pneumonia. Oxygen saturation was measured using a portable fingertip pulse oximeter, a handheld pulse oximeter, and arterial blood gas analysis. Results: Eighty-six children were included. SpO2 PF underestimated oxygen levels by 0.126% (95% CI -0.240 to 0.491), while SpO2H underestimated it by 0.323% (95% CI -0.075 to 0.721). Between portable and handheld readings, the mean difference was 0.198% (95% CI -0.089 to 0.484). Across the three methods, limits of agreement ranged from -3.388 to +4.035%. There was no statistically significant difference in variance among the three measurements. Children with tachypnea (cOR 2.623, 95% CI 1.06 – 6.48, p = 0.037), difficulty breathing (cOR 6.316, 95% CI 1.96 – 20.34, p = 0.002), and subcostal retractions (cOR 2.842, 95% CI 1.05 to 7.69, p = 0.040) were more likely to have hypoxemia. Conclusion: Pulse oximetry closely correlates with arterial blood gas analysis within acceptable limits of agreement and with no significant differences in variance among measurements. Difficulty breathing, tachypnea and subcostal retractions were significantly more likely to be observed in hypoxemic children.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Clinical Profile and Treatment Outcomes Of Acute Cholangitis in Children in a Tertiary Government Hospital in the Philippines: A Five-Year Retrospective Study. SARS-CoV-2 RT-PCR cycle threshold value and its association with disease severity and mortality among hospitalized pediatric covid-19 patients. Clinical and Microbiological Profile and Factors Affecting Outcome among Pediatric Febrile Neutropenic Patients with Hematologic Malignancies. Aye, AI Captain! The Coronavirus Disease 2019 (COVID-19) Immunoglobulin (IgG) Levels Using Chemiluminescence Immunoassay (CLIA) Anti-S-RBD Test in Term Neonates Born to COVID-19 Fully Vaccinated Mothers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1