J. Furukawa, Asuka Takai, J. Morimoto
{"title":"基于生物信号的机器人协同滤波控制的数据库驱动方法","authors":"J. Furukawa, Asuka Takai, J. Morimoto","doi":"10.1109/HUMANOIDS.2017.8246934","DOIUrl":null,"url":null,"abstract":"In this study, we propose a databasedriven torque estimation approach for EMG-based robot control. For conventional EMG-based controllers, torque estimation models need to be carefully calibrated to control robots that have multiple degrees of freedom. However, such a calibration procedure requires significant effort and restricts the applications of EMG-based methods to practical situations. To cope with this issue, we use large-scale data acquired from other users to avoid the calibration process and propose collaborative filtering to estimate the joint torque of a new user by exploiting the previously derived relationships between the EMG signals and the joint torque of other users. To validate our proposed method, we compared the joint torque estimation performance with a standard linear conversion model. In our experiments, we controlled an upper-limb exoskeleton robot with the estimated joint torque where we used 16-ch electrodes to measure the EMG signals of subjects. In a comparison, our proposed method showed comparable control performance with the standard approach that requires a careful calibration process.","PeriodicalId":143992,"journal":{"name":"2017 IEEE-RAS 17th International Conference on Humanoid Robotics (Humanoids)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Database-driven approach for Biosignal-based robot control with collaborative filtering\",\"authors\":\"J. Furukawa, Asuka Takai, J. Morimoto\",\"doi\":\"10.1109/HUMANOIDS.2017.8246934\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, we propose a databasedriven torque estimation approach for EMG-based robot control. For conventional EMG-based controllers, torque estimation models need to be carefully calibrated to control robots that have multiple degrees of freedom. However, such a calibration procedure requires significant effort and restricts the applications of EMG-based methods to practical situations. To cope with this issue, we use large-scale data acquired from other users to avoid the calibration process and propose collaborative filtering to estimate the joint torque of a new user by exploiting the previously derived relationships between the EMG signals and the joint torque of other users. To validate our proposed method, we compared the joint torque estimation performance with a standard linear conversion model. In our experiments, we controlled an upper-limb exoskeleton robot with the estimated joint torque where we used 16-ch electrodes to measure the EMG signals of subjects. In a comparison, our proposed method showed comparable control performance with the standard approach that requires a careful calibration process.\",\"PeriodicalId\":143992,\"journal\":{\"name\":\"2017 IEEE-RAS 17th International Conference on Humanoid Robotics (Humanoids)\",\"volume\":\"72 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE-RAS 17th International Conference on Humanoid Robotics (Humanoids)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HUMANOIDS.2017.8246934\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE-RAS 17th International Conference on Humanoid Robotics (Humanoids)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HUMANOIDS.2017.8246934","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在这项研究中,我们提出了一种数据库驱动的基于肌电图的机器人控制力矩估计方法。对于传统的基于肌电图的控制器,需要仔细校准扭矩估计模型以控制具有多个自由度的机器人。然而,这样的校准过程需要大量的努力,并且限制了基于肌电图的方法在实际情况中的应用。为了解决这个问题,我们使用从其他用户获取的大量数据来避免校准过程,并提出协同滤波,利用先前导出的肌电信号与其他用户关节扭矩之间的关系来估计新用户的关节扭矩。为了验证我们提出的方法,我们将关节转矩估计性能与标准线性转换模型进行了比较。在我们的实验中,我们用估计的关节扭矩控制上肢外骨骼机器人,并使用16-ch电极测量受试者的肌电信号。在比较中,我们提出的方法显示出与需要仔细校准过程的标准方法相当的控制性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Database-driven approach for Biosignal-based robot control with collaborative filtering
In this study, we propose a databasedriven torque estimation approach for EMG-based robot control. For conventional EMG-based controllers, torque estimation models need to be carefully calibrated to control robots that have multiple degrees of freedom. However, such a calibration procedure requires significant effort and restricts the applications of EMG-based methods to practical situations. To cope with this issue, we use large-scale data acquired from other users to avoid the calibration process and propose collaborative filtering to estimate the joint torque of a new user by exploiting the previously derived relationships between the EMG signals and the joint torque of other users. To validate our proposed method, we compared the joint torque estimation performance with a standard linear conversion model. In our experiments, we controlled an upper-limb exoskeleton robot with the estimated joint torque where we used 16-ch electrodes to measure the EMG signals of subjects. In a comparison, our proposed method showed comparable control performance with the standard approach that requires a careful calibration process.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Stiffness evaluation of a tendon-driven robot with variable joint stiffness mechanisms Investigations of viscoelastic liquid cooled actuators applied for dynamic motion control of legged systems Tilt estimator for 3D non-rigid pendulum based on a tri-axial accelerometer and gyrometer Optimal and robust walking using intrinsic properties of a series-elastic robot Experimental evaluation of simple estimators for humanoid robots
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1