Bo-fan Zhou, Shou-bei Wang, Ke Li, Jing-feng Bai, Xiang Ji
{"title":"热电偶阵列b模超声引导相控阵聚焦超声系统瞄准精度的实验评价","authors":"Bo-fan Zhou, Shou-bei Wang, Ke Li, Jing-feng Bai, Xiang Ji","doi":"10.1109/SPAWDA.2015.7364486","DOIUrl":null,"url":null,"abstract":"Image-guide high-intensity focused ultrasound (HIFU) has been widely used in the treatment of uterine fibroids. However, before HIFU system is ready for use, the targeting accuracy should be known for the safety of important abdominal organs surrounding the target. Researchers have used magnetic resonance (MR) images or computed tomography (CT) to evaluate the targeting accuracy of current MR-guided HIFU systems, whereas these methods cannot be directly used in the ultrasound-guided HIFU (USgHIFU) systems. In this study, a thermocouple array is used in combination with the in-house built acrylic plate to evaluate the targeting accuracy of the existing 112-channel phased-array USgHIFU system. The results of ex vivo experiment demonstrate the feasibility and the efficacy of the thermocouple array in the evaluation, and the targeting accuracy of the USgHIFU system is about 1mm in the focal plane. Thus, this accuracy is adequate for the treatment of uterine fibroids.","PeriodicalId":205914,"journal":{"name":"2015 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications (SPAWDA)","volume":"30 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental evaluation of targeting accuracy of a B-mode ultrasound-guided phased-array focused ultrasound system using a thermocouple array\",\"authors\":\"Bo-fan Zhou, Shou-bei Wang, Ke Li, Jing-feng Bai, Xiang Ji\",\"doi\":\"10.1109/SPAWDA.2015.7364486\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Image-guide high-intensity focused ultrasound (HIFU) has been widely used in the treatment of uterine fibroids. However, before HIFU system is ready for use, the targeting accuracy should be known for the safety of important abdominal organs surrounding the target. Researchers have used magnetic resonance (MR) images or computed tomography (CT) to evaluate the targeting accuracy of current MR-guided HIFU systems, whereas these methods cannot be directly used in the ultrasound-guided HIFU (USgHIFU) systems. In this study, a thermocouple array is used in combination with the in-house built acrylic plate to evaluate the targeting accuracy of the existing 112-channel phased-array USgHIFU system. The results of ex vivo experiment demonstrate the feasibility and the efficacy of the thermocouple array in the evaluation, and the targeting accuracy of the USgHIFU system is about 1mm in the focal plane. Thus, this accuracy is adequate for the treatment of uterine fibroids.\",\"PeriodicalId\":205914,\"journal\":{\"name\":\"2015 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications (SPAWDA)\",\"volume\":\"30 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications (SPAWDA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPAWDA.2015.7364486\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications (SPAWDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPAWDA.2015.7364486","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Experimental evaluation of targeting accuracy of a B-mode ultrasound-guided phased-array focused ultrasound system using a thermocouple array
Image-guide high-intensity focused ultrasound (HIFU) has been widely used in the treatment of uterine fibroids. However, before HIFU system is ready for use, the targeting accuracy should be known for the safety of important abdominal organs surrounding the target. Researchers have used magnetic resonance (MR) images or computed tomography (CT) to evaluate the targeting accuracy of current MR-guided HIFU systems, whereas these methods cannot be directly used in the ultrasound-guided HIFU (USgHIFU) systems. In this study, a thermocouple array is used in combination with the in-house built acrylic plate to evaluate the targeting accuracy of the existing 112-channel phased-array USgHIFU system. The results of ex vivo experiment demonstrate the feasibility and the efficacy of the thermocouple array in the evaluation, and the targeting accuracy of the USgHIFU system is about 1mm in the focal plane. Thus, this accuracy is adequate for the treatment of uterine fibroids.