比较无滑动墙的后端结构和地震区的滑动墙建模进行比较

Tondi Amirsyah Putera, F. Hidayat
{"title":"比较无滑动墙的后端结构和地震区的滑动墙建模进行比较","authors":"Tondi Amirsyah Putera, F. Hidayat","doi":"10.30811/portal.v9i1.611","DOIUrl":null,"url":null,"abstract":"The high-rise building structure is prone to lateral forces, mainly due to the force generated by the earthquake. In calculating the multilevel building structure there are 2 ways, namely with Open Frame and Open Frame combination with shear wall. The shear wall is a wall that acts as a stiffener and is also a core wall for rigging entire buildings designed to withstand shear forces, lateral forces caused by earthquakes. so that the horizontal deformation (deflection) becomes small. The analysis used in this research is spectrum response analysis based on SNI 1726: 2012. This research has 3 model of set back building which will be reviewed, that is the model of set back building with special moment frame system, the model of backyard building with shear wall of each side and model of set back building with shear wall only on one side. All load inputs, stiffness and structural dimensions are the same, which differ only the special moment frame system model and the sliding wall placement used. This building has a height of 39.5 meters (10 floors). Based on this data it shows that the deviation result with the deviation modeling for the model is 0.075 m for the X and 0.064 direction for the Y direction for model 2 0.051 m for the X and 0.050 m directions for the Y direction and for model 3 is 0.074 m for the X and 0.048 for direction Y.Keywords: Set Back, Irregular Building, Drift Story, Shear Shear, Shear Wall, Special Moment Resume Frame.","PeriodicalId":378653,"journal":{"name":"Portal: Jurnal Teknik Sipil","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"ANALISA PERBANDINGAN SIMPANGAN STRUKTUR GEDUNG SET BACK TANPA DINDING GESER DAN PEMODELAN LETAK DINDING GESER DI ZONA GEMPA TINGGI\",\"authors\":\"Tondi Amirsyah Putera, F. Hidayat\",\"doi\":\"10.30811/portal.v9i1.611\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The high-rise building structure is prone to lateral forces, mainly due to the force generated by the earthquake. In calculating the multilevel building structure there are 2 ways, namely with Open Frame and Open Frame combination with shear wall. The shear wall is a wall that acts as a stiffener and is also a core wall for rigging entire buildings designed to withstand shear forces, lateral forces caused by earthquakes. so that the horizontal deformation (deflection) becomes small. The analysis used in this research is spectrum response analysis based on SNI 1726: 2012. This research has 3 model of set back building which will be reviewed, that is the model of set back building with special moment frame system, the model of backyard building with shear wall of each side and model of set back building with shear wall only on one side. All load inputs, stiffness and structural dimensions are the same, which differ only the special moment frame system model and the sliding wall placement used. This building has a height of 39.5 meters (10 floors). Based on this data it shows that the deviation result with the deviation modeling for the model is 0.075 m for the X and 0.064 direction for the Y direction for model 2 0.051 m for the X and 0.050 m directions for the Y direction and for model 3 is 0.074 m for the X and 0.048 for direction Y.Keywords: Set Back, Irregular Building, Drift Story, Shear Shear, Shear Wall, Special Moment Resume Frame.\",\"PeriodicalId\":378653,\"journal\":{\"name\":\"Portal: Jurnal Teknik Sipil\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Portal: Jurnal Teknik Sipil\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30811/portal.v9i1.611\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Portal: Jurnal Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30811/portal.v9i1.611","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

高层建筑结构容易产生侧向力,主要是由于地震产生的力。在多层建筑结构的计算中,有两种方法,即开放框架和开放框架与剪力墙的组合。剪力墙是一种作为加强筋的墙,也是支撑整个建筑的核心墙,旨在承受地震引起的剪力和侧向力。使水平变形(挠度)变小。本研究使用的分析是基于SNI 1726: 2012的频谱响应分析。本研究有三种后退建筑模型,分别是特殊弯矩框架体系后退建筑模型、两侧各有剪力墙的后院建筑模型和仅一侧有剪力墙的后退建筑模型。所有荷载输入、刚度和结构尺寸都是相同的,不同的只是特殊弯矩框架体系模型和所使用的滑动墙布置。这座建筑高39.5米(10层)。根据该数据可知,模型的偏差建模结果在X方向为0.075 m, Y方向为0.064 m,模型2的X方向为0.051 m, Y方向为0.050 m,模型3的X方向为0.074 m, Y方向为0.048 m。关键词:逆退,不规则建筑,漂移层,剪力墙,特殊力矩恢复框架。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ANALISA PERBANDINGAN SIMPANGAN STRUKTUR GEDUNG SET BACK TANPA DINDING GESER DAN PEMODELAN LETAK DINDING GESER DI ZONA GEMPA TINGGI
The high-rise building structure is prone to lateral forces, mainly due to the force generated by the earthquake. In calculating the multilevel building structure there are 2 ways, namely with Open Frame and Open Frame combination with shear wall. The shear wall is a wall that acts as a stiffener and is also a core wall for rigging entire buildings designed to withstand shear forces, lateral forces caused by earthquakes. so that the horizontal deformation (deflection) becomes small. The analysis used in this research is spectrum response analysis based on SNI 1726: 2012. This research has 3 model of set back building which will be reviewed, that is the model of set back building with special moment frame system, the model of backyard building with shear wall of each side and model of set back building with shear wall only on one side. All load inputs, stiffness and structural dimensions are the same, which differ only the special moment frame system model and the sliding wall placement used. This building has a height of 39.5 meters (10 floors). Based on this data it shows that the deviation result with the deviation modeling for the model is 0.075 m for the X and 0.064 direction for the Y direction for model 2 0.051 m for the X and 0.050 m directions for the Y direction and for model 3 is 0.074 m for the X and 0.048 for direction Y.Keywords: Set Back, Irregular Building, Drift Story, Shear Shear, Shear Wall, Special Moment Resume Frame.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prototype Jembatan Tipe Plate Girder U (PGU) dengan Lantai Orthotropic Komposit Evaluasi Deskriptif Sistem Pembayaran Bus Rapid Transit Estimasi Biaya Proyek pada Kontrakor Skala Kecil di Bali pada Masa Pandemi COVID-19 3 Floor Luxury House Structure Design Planning Using ETABS Software Cover
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1