光伏系统并网逆变器与电能质量:案例研究

F. Spertino, P. Di Leo, F. Corona, F. Papandrea
{"title":"光伏系统并网逆变器与电能质量:案例研究","authors":"F. Spertino, P. Di Leo, F. Corona, F. Papandrea","doi":"10.1109/PEDG.2012.6254058","DOIUrl":null,"url":null,"abstract":"The Power Quality (PQ) issues are here assessed from an experimental point of view concerning the grid-connected PhotoVoltaic (PV) systems. After an introduction to the new regulations for smart grid connection in presence of Distributed Generators, the work concentrates the attention on a variety of power inverters both in normal and in unusual operation. In particular the PQ problems in case of shading effect on the PV modules are highlighted. The corresponding increase of harmonic content and unbalance, together with the decrease of power factor, is assessed in the paper.","PeriodicalId":146438,"journal":{"name":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"Inverters for grid connection of photovoltaic systems and power quality: Case studies\",\"authors\":\"F. Spertino, P. Di Leo, F. Corona, F. Papandrea\",\"doi\":\"10.1109/PEDG.2012.6254058\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Power Quality (PQ) issues are here assessed from an experimental point of view concerning the grid-connected PhotoVoltaic (PV) systems. After an introduction to the new regulations for smart grid connection in presence of Distributed Generators, the work concentrates the attention on a variety of power inverters both in normal and in unusual operation. In particular the PQ problems in case of shading effect on the PV modules are highlighted. The corresponding increase of harmonic content and unbalance, together with the decrease of power factor, is assessed in the paper.\",\"PeriodicalId\":146438,\"journal\":{\"name\":\"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDG.2012.6254058\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDG.2012.6254058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

摘要

本文从实验的角度对并网光伏系统的电能质量问题进行了评估。介绍了分布式发电机组智能并网的新规定,重点介绍了各种正常运行和非正常运行的逆变器。特别强调了在光伏组件遮阳效应的情况下的PQ问题。文中分析了相应的谐波含量和不平衡的增加以及功率因数的降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Inverters for grid connection of photovoltaic systems and power quality: Case studies
The Power Quality (PQ) issues are here assessed from an experimental point of view concerning the grid-connected PhotoVoltaic (PV) systems. After an introduction to the new regulations for smart grid connection in presence of Distributed Generators, the work concentrates the attention on a variety of power inverters both in normal and in unusual operation. In particular the PQ problems in case of shading effect on the PV modules are highlighted. The corresponding increase of harmonic content and unbalance, together with the decrease of power factor, is assessed in the paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Smart — STATCOM control strategy implementation in wind power plants Common DC link in residential LV network to improve the penetration level of Small-Scale Embedded Generators Research on the reactive power optimization of distribution network including DG Use of petri nets for load sharing control in distributed generation applications Mega data center architecture under Smart Grid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1