Q. K. Mohsin, Xiangning Lin, Zhicheng Wang, M. S. Khalid, Zhengxin Zhou, P. Zheng
{"title":"伊拉克网400kV, 50Hz与伊朗、土耳其、叙利亚互联,采用SVC区域间振荡阻尼和电压调节","authors":"Q. K. Mohsin, Xiangning Lin, Zhicheng Wang, M. S. Khalid, Zhengxin Zhou, P. Zheng","doi":"10.1109/APPEEC.2014.7065992","DOIUrl":null,"url":null,"abstract":"Electromechanical oscillations one of the most important stability limits constraining power transfer between two countries. This paper presents different power system electromechanical oscillation types, and focuses on inter-area oscillation, where SVC is chosen to be installed at the midpoint of long tie line between Iraq and Turkey, so as to be more effective for two options: the first option is to use the SVC for inter-area oscillation damping, in case of system oscillation occurring in a 3-ph-to-ground short circuit fault at the tie transmission line between countries near the exporting area which is removed after 100ms, and the second option is to use it as a voltage regulator of this long transmission line. The control operation of the SVC is accomplished with the control signal from remote control unit such as WAMS. By using Matlab and Simulink, different simulation results are presented based on various scenarios.","PeriodicalId":206418,"journal":{"name":"2014 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Iraq network 400kV, 50Hz interconnect with Iran, Turkey and Syria inter-area oscillation damping and voltage regulation by using SVC\",\"authors\":\"Q. K. Mohsin, Xiangning Lin, Zhicheng Wang, M. S. Khalid, Zhengxin Zhou, P. Zheng\",\"doi\":\"10.1109/APPEEC.2014.7065992\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electromechanical oscillations one of the most important stability limits constraining power transfer between two countries. This paper presents different power system electromechanical oscillation types, and focuses on inter-area oscillation, where SVC is chosen to be installed at the midpoint of long tie line between Iraq and Turkey, so as to be more effective for two options: the first option is to use the SVC for inter-area oscillation damping, in case of system oscillation occurring in a 3-ph-to-ground short circuit fault at the tie transmission line between countries near the exporting area which is removed after 100ms, and the second option is to use it as a voltage regulator of this long transmission line. The control operation of the SVC is accomplished with the control signal from remote control unit such as WAMS. By using Matlab and Simulink, different simulation results are presented based on various scenarios.\",\"PeriodicalId\":206418,\"journal\":{\"name\":\"2014 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APPEEC.2014.7065992\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2014.7065992","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Iraq network 400kV, 50Hz interconnect with Iran, Turkey and Syria inter-area oscillation damping and voltage regulation by using SVC
Electromechanical oscillations one of the most important stability limits constraining power transfer between two countries. This paper presents different power system electromechanical oscillation types, and focuses on inter-area oscillation, where SVC is chosen to be installed at the midpoint of long tie line between Iraq and Turkey, so as to be more effective for two options: the first option is to use the SVC for inter-area oscillation damping, in case of system oscillation occurring in a 3-ph-to-ground short circuit fault at the tie transmission line between countries near the exporting area which is removed after 100ms, and the second option is to use it as a voltage regulator of this long transmission line. The control operation of the SVC is accomplished with the control signal from remote control unit such as WAMS. By using Matlab and Simulink, different simulation results are presented based on various scenarios.