{"title":"带TCSC的输电线路距离保护性能评价","authors":"Sauvik Biswas, P. K. Nayak","doi":"10.1109/ICCECE.2016.8009536","DOIUrl":null,"url":null,"abstract":"In this paper, a Thyristor Controlled Series Capacitor (TCSC) is studied and simulated by using EMTDC/PSCAD software. Different fault cases are generated by placing the TCSC at the middle of the transmission line of a two source equivalent power system. The fault data are used for evaluating the performance of the distance relay placed at one end of the line. The findings are reported in this paper for few representative test cases. The observations clearly show that by using only conventional distance relaying based protection scheme reliable protection for TCSC based transmission line cannot be achieved. Thus, additional algorithms are required which can support conventional distance relaying for protecting such transmission systems.","PeriodicalId":414303,"journal":{"name":"2016 International Conference on Computer, Electrical & Communication Engineering (ICCECE)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The performance evaluation of distance protection for transmission lines possessing TCSC\",\"authors\":\"Sauvik Biswas, P. K. Nayak\",\"doi\":\"10.1109/ICCECE.2016.8009536\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a Thyristor Controlled Series Capacitor (TCSC) is studied and simulated by using EMTDC/PSCAD software. Different fault cases are generated by placing the TCSC at the middle of the transmission line of a two source equivalent power system. The fault data are used for evaluating the performance of the distance relay placed at one end of the line. The findings are reported in this paper for few representative test cases. The observations clearly show that by using only conventional distance relaying based protection scheme reliable protection for TCSC based transmission line cannot be achieved. Thus, additional algorithms are required which can support conventional distance relaying for protecting such transmission systems.\",\"PeriodicalId\":414303,\"journal\":{\"name\":\"2016 International Conference on Computer, Electrical & Communication Engineering (ICCECE)\",\"volume\":\"79 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Conference on Computer, Electrical & Communication Engineering (ICCECE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCECE.2016.8009536\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Computer, Electrical & Communication Engineering (ICCECE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCECE.2016.8009536","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文利用EMTDC/PSCAD软件对晶闸管控制串联电容器(TCSC)进行了仿真研究。在双源等效电力系统中,将TCSC置于传输线的中间会产生不同的故障情况。故障数据用于评估放置在线路一端的距离继电器的性能。本文报告了几个有代表性的测试用例的发现。观察结果清楚地表明,仅采用传统的基于距离继电保护方案无法实现对基于TCSC的传输线的可靠保护。因此,需要额外的算法来支持保护这种传输系统的传统距离继电器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The performance evaluation of distance protection for transmission lines possessing TCSC
In this paper, a Thyristor Controlled Series Capacitor (TCSC) is studied and simulated by using EMTDC/PSCAD software. Different fault cases are generated by placing the TCSC at the middle of the transmission line of a two source equivalent power system. The fault data are used for evaluating the performance of the distance relay placed at one end of the line. The findings are reported in this paper for few representative test cases. The observations clearly show that by using only conventional distance relaying based protection scheme reliable protection for TCSC based transmission line cannot be achieved. Thus, additional algorithms are required which can support conventional distance relaying for protecting such transmission systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A simulation based performance analysis of proactive, reactive and hybrid routing protocol Enhancement of optical absorption in Plasmonic thin film solar cell Task management of robot using cloud computing Study of the effect of air gap in segmented cylindrical dielectric resonator loaded monopole Model order reduction of high order LTI system using particle swarm optimisation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1