基于传感器技术的优秀掷斧运动员上肢运动学研究

Stuart A. Evans, R. Bini
{"title":"基于传感器技术的优秀掷斧运动员上肢运动学研究","authors":"Stuart A. Evans, R. Bini","doi":"10.53520/rdsp2023.10558","DOIUrl":null,"url":null,"abstract":"Introduction: This field-based case study assessed linear accelerations of the scapula and elbow in an elite axe thrower in three different axe throwing techniques using two wearable sensors.\nMethods: One elite axe thrower (35 years; height 181 cm; weight 92 kg) participated in this case study. One wearable sensor (an accelerometer) was located on the dorsal surface of the upper thorax between the medial borders of the scapula. An additional sensor was located on the medial epicondyle of the right elbow to capture linear acceleration magnitudes. The participant performed three different throwing techniques, namely a one hand underarm throw, a two-handed overhead throw, and a one hand overarm throw for a total of four repetitions.\nResults: Significant differences in scapula acceleration magnitudes were detected in the three throwing techniques analyzed along with significant differences in all acceleration channels (p < 0.001). In contrast, no significant differences in triaxial acceleration magnitude were observed in the elbow in all throwing techniques (p > 0.50).\nConclusions: Magnitudes of scapular acceleration varied significantly depending on the type of throw. In contrast, acceleration magnitudes at the elbow displayed high variability despite a non-significant outcome. A wearable sensor could be a valuable tool to enhance throwing performance.","PeriodicalId":332159,"journal":{"name":"Research Directs in Strength and Performance","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Case Study in Upper Body Kinematics of an Elite Axe Thrower Using Sensor Technology\",\"authors\":\"Stuart A. Evans, R. Bini\",\"doi\":\"10.53520/rdsp2023.10558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: This field-based case study assessed linear accelerations of the scapula and elbow in an elite axe thrower in three different axe throwing techniques using two wearable sensors.\\nMethods: One elite axe thrower (35 years; height 181 cm; weight 92 kg) participated in this case study. One wearable sensor (an accelerometer) was located on the dorsal surface of the upper thorax between the medial borders of the scapula. An additional sensor was located on the medial epicondyle of the right elbow to capture linear acceleration magnitudes. The participant performed three different throwing techniques, namely a one hand underarm throw, a two-handed overhead throw, and a one hand overarm throw for a total of four repetitions.\\nResults: Significant differences in scapula acceleration magnitudes were detected in the three throwing techniques analyzed along with significant differences in all acceleration channels (p < 0.001). In contrast, no significant differences in triaxial acceleration magnitude were observed in the elbow in all throwing techniques (p > 0.50).\\nConclusions: Magnitudes of scapular acceleration varied significantly depending on the type of throw. In contrast, acceleration magnitudes at the elbow displayed high variability despite a non-significant outcome. A wearable sensor could be a valuable tool to enhance throwing performance.\",\"PeriodicalId\":332159,\"journal\":{\"name\":\"Research Directs in Strength and Performance\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research Directs in Strength and Performance\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53520/rdsp2023.10558\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research Directs in Strength and Performance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53520/rdsp2023.10558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

简介:本研究以现场为基础,使用两个可穿戴传感器,评估了一名优秀的斧头投掷者在三种不同的斧头投掷技术中肩胛骨和肘部的线性加速度。方法:优秀掷斧运动员1例(35岁;身高181厘米;体重92 kg)参加了本案例研究。一个可穿戴传感器(加速度计)位于肩胛骨内侧边界之间的上胸背表面。另一个传感器位于右肘内侧上髁,以捕获线加速度的大小。参与者进行了三种不同的投掷技术,即单手腋下投掷,双手头顶投掷和单手手臂上投掷,共重复四次。结果:在三种投掷技术中,肩胛骨加速度大小有显著差异,所有加速通道也有显著差异(p < 0.001)。相比之下,在所有投掷技术中,肘关节的三轴加速度大小没有显著差异(p > 0.50)。结论:肩胛骨加速度的大小随投掷类型的不同而显著变化。相比之下,肘部的加速度大小显示出高度可变性,尽管结果不显著。可穿戴传感器可能是提高投掷性能的宝贵工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Case Study in Upper Body Kinematics of an Elite Axe Thrower Using Sensor Technology
Introduction: This field-based case study assessed linear accelerations of the scapula and elbow in an elite axe thrower in three different axe throwing techniques using two wearable sensors. Methods: One elite axe thrower (35 years; height 181 cm; weight 92 kg) participated in this case study. One wearable sensor (an accelerometer) was located on the dorsal surface of the upper thorax between the medial borders of the scapula. An additional sensor was located on the medial epicondyle of the right elbow to capture linear acceleration magnitudes. The participant performed three different throwing techniques, namely a one hand underarm throw, a two-handed overhead throw, and a one hand overarm throw for a total of four repetitions. Results: Significant differences in scapula acceleration magnitudes were detected in the three throwing techniques analyzed along with significant differences in all acceleration channels (p < 0.001). In contrast, no significant differences in triaxial acceleration magnitude were observed in the elbow in all throwing techniques (p > 0.50). Conclusions: Magnitudes of scapular acceleration varied significantly depending on the type of throw. In contrast, acceleration magnitudes at the elbow displayed high variability despite a non-significant outcome. A wearable sensor could be a valuable tool to enhance throwing performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Influence of a Supervised and Unsupervised Strength and Conditioning Program for Elite Adolescent Freestyle Swimmers A Pilot Study of the Effects of Collagen vs. Whey Protein Supplementation on Delayed Onset Muscle Soreness in Healthy Individuals Nutritional Practices Among Professional Indoor and Beach Volleyball Players: A Brief Narrative Review Validity of B-Mode Ultrasound for Body Composition Assessment in the Field In Deep Water: A Case Study on Kinematics in Deep Water Running
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1