磁传感器连续监测眼压的可行性研究

F. Bertoncini, R. Giannetti, B. Tellini
{"title":"磁传感器连续监测眼压的可行性研究","authors":"F. Bertoncini, R. Giannetti, B. Tellini","doi":"10.1109/SFICON.2002.1159825","DOIUrl":null,"url":null,"abstract":"A feasibility study on an intraocular magnetic sensor for continuous monitoring of the pressure inside the eyes is introduced. In this first approach the system consists on a coil designed for special goggles and on a small cylinder of magnetic material aimed at simulating the magnetic sensor. The analysis has been carried out from both an experimental and theoretical point of view. In particular perturbative methods have been adopted for evaluating the inductance variation. Results from measurements have shown a good agreement with theory and they appear to be encouraging for further studies.","PeriodicalId":294424,"journal":{"name":"2nd ISA/IEEE Sensors for Industry Conference,","volume":"89 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A magnetic sensors feasibility investigation for continuous intraocular pressure monitoring\",\"authors\":\"F. Bertoncini, R. Giannetti, B. Tellini\",\"doi\":\"10.1109/SFICON.2002.1159825\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A feasibility study on an intraocular magnetic sensor for continuous monitoring of the pressure inside the eyes is introduced. In this first approach the system consists on a coil designed for special goggles and on a small cylinder of magnetic material aimed at simulating the magnetic sensor. The analysis has been carried out from both an experimental and theoretical point of view. In particular perturbative methods have been adopted for evaluating the inductance variation. Results from measurements have shown a good agreement with theory and they appear to be encouraging for further studies.\",\"PeriodicalId\":294424,\"journal\":{\"name\":\"2nd ISA/IEEE Sensors for Industry Conference,\",\"volume\":\"89 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2nd ISA/IEEE Sensors for Industry Conference,\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SFICON.2002.1159825\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2nd ISA/IEEE Sensors for Industry Conference,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SFICON.2002.1159825","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

介绍了眼内磁传感器连续监测眼内压力的可行性研究。在第一种方法中,系统包括为特殊护目镜设计的线圈和旨在模拟磁传感器的磁性材料的小圆柱体。从实验和理论两个角度进行了分析。特别是采用了微扰法来计算电感的变化。测量结果与理论很好地吻合,似乎对进一步的研究具有鼓舞作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A magnetic sensors feasibility investigation for continuous intraocular pressure monitoring
A feasibility study on an intraocular magnetic sensor for continuous monitoring of the pressure inside the eyes is introduced. In this first approach the system consists on a coil designed for special goggles and on a small cylinder of magnetic material aimed at simulating the magnetic sensor. The analysis has been carried out from both an experimental and theoretical point of view. In particular perturbative methods have been adopted for evaluating the inductance variation. Results from measurements have shown a good agreement with theory and they appear to be encouraging for further studies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
IEEE 1588 standard for a precision clock synchronization protocol for networked measurement and control systems Design of a MEMS-based, 3-axis accelerometer smart sensor An implementation of IEEE 1451 NCAP for Internet access of serial port-based sensors A networked smart sensor system for gripper of robots Laser sensor for imaging and detection of cutting tool wear
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1