由电机平衡引起的电流不稳定现象的数值检测

D. Olaru, D. Floricau
{"title":"由电机平衡引起的电流不稳定现象的数值检测","authors":"D. Olaru, D. Floricau","doi":"10.1109/ISNCC.2008.4627495","DOIUrl":null,"url":null,"abstract":"The instabilities arising in the power delivery network may cause serious problems for the whole system security. The most difficult detectable event is the energy balance phenomena. This has specific evolution characteristics, which are not so easy to be observed. The paper presents a real type situation, studied on a physically realized model, on a reduced scale. It is based on a permanent magnet synchronous motor. This is susceptible to give similar balance phenomena as conventional loaded equipment. The supply source is tuned as to obtain quasi-stable motion. The current and voltage evolution is represented in the phasespsila plane. To result a smooth enough wave, regression methods are used. In order to obtain useful information about the instability characteristics, special indicator functions are used. They emphasize, on one hand, the relative balance parameters and, on the other hand, the most unstable moment of evolution. This gives a discontinuous evolution for the derivativespsila variation for the current wave. The paper presents, as well, the mathematical background and the methods used for the processing of the measured parameters.","PeriodicalId":143815,"journal":{"name":"2008 International School on Nonsinusoidal Currents and Compensation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical detection of the current instability phenomena due to the balance of the electric machines\",\"authors\":\"D. Olaru, D. Floricau\",\"doi\":\"10.1109/ISNCC.2008.4627495\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The instabilities arising in the power delivery network may cause serious problems for the whole system security. The most difficult detectable event is the energy balance phenomena. This has specific evolution characteristics, which are not so easy to be observed. The paper presents a real type situation, studied on a physically realized model, on a reduced scale. It is based on a permanent magnet synchronous motor. This is susceptible to give similar balance phenomena as conventional loaded equipment. The supply source is tuned as to obtain quasi-stable motion. The current and voltage evolution is represented in the phasespsila plane. To result a smooth enough wave, regression methods are used. In order to obtain useful information about the instability characteristics, special indicator functions are used. They emphasize, on one hand, the relative balance parameters and, on the other hand, the most unstable moment of evolution. This gives a discontinuous evolution for the derivativespsila variation for the current wave. The paper presents, as well, the mathematical background and the methods used for the processing of the measured parameters.\",\"PeriodicalId\":143815,\"journal\":{\"name\":\"2008 International School on Nonsinusoidal Currents and Compensation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 International School on Nonsinusoidal Currents and Compensation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISNCC.2008.4627495\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 International School on Nonsinusoidal Currents and Compensation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISNCC.2008.4627495","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

输电网的不稳定可能会对整个系统的安全造成严重的影响。最难探测到的事件是能量平衡现象。这具有特定的进化特征,不容易被观察到。本文给出了一个真实的情况,研究了一个物理实现的模型,在缩小的规模。它以永磁同步电动机为基础。这很容易产生与传统负载设备类似的平衡现象。对电源进行了调谐,以获得准稳定运动。在相位平面上表示电流和电压的演变。为了得到一个足够平滑的波,使用了回归方法。为了获得有关不稳定特性的有用信息,使用了特殊的指示函数。他们一方面强调相对平衡参数,另一方面强调进化过程中最不稳定的时刻。这就给出了电流波的导数波动的不连续演化。本文还介绍了测量参数处理的数学背景和方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Numerical detection of the current instability phenomena due to the balance of the electric machines
The instabilities arising in the power delivery network may cause serious problems for the whole system security. The most difficult detectable event is the energy balance phenomena. This has specific evolution characteristics, which are not so easy to be observed. The paper presents a real type situation, studied on a physically realized model, on a reduced scale. It is based on a permanent magnet synchronous motor. This is susceptible to give similar balance phenomena as conventional loaded equipment. The supply source is tuned as to obtain quasi-stable motion. The current and voltage evolution is represented in the phasespsila plane. To result a smooth enough wave, regression methods are used. In order to obtain useful information about the instability characteristics, special indicator functions are used. They emphasize, on one hand, the relative balance parameters and, on the other hand, the most unstable moment of evolution. This gives a discontinuous evolution for the derivativespsila variation for the current wave. The paper presents, as well, the mathematical background and the methods used for the processing of the measured parameters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Instantaneous single-phase system power demonstration using virtual two phase theory Power quality conditioners with minimum number of current sensor requirement Power electronics active filter with controlled dynamics Conditions of CM voltage cancellation in multilevel voltage inverters with conventional and improved carrier-based SVPWM Natural doubling of the apparent switching frequency using three-level ANPC converter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1