{"title":"连续波激光在1.07微米处诱导AMTIR-1、2、5和7硫族化物窗口的损伤阈值","authors":"J. McElhenny, N. Bambha","doi":"10.1117/12.2572934","DOIUrl":null,"url":null,"abstract":"The continuous wave laser-induced damage thresholds of Amorphous Materials chalcogenide glasses, Amorphous Materials AMTIR-1, AMTIR-2, AMTIR-5, and AMTIR-7 are measured for a 5s exposure of 1.07 μm light focused to a spot size with 1/e2 diameter of 830 μm or 1044 μm, following the International Organization for Standardization standards.","PeriodicalId":202227,"journal":{"name":"Laser Damage","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous wave laser induced damage threshold of AMTIR-1, 2, 5 and 7 chalcogenide windows at 1.07 microns\",\"authors\":\"J. McElhenny, N. Bambha\",\"doi\":\"10.1117/12.2572934\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The continuous wave laser-induced damage thresholds of Amorphous Materials chalcogenide glasses, Amorphous Materials AMTIR-1, AMTIR-2, AMTIR-5, and AMTIR-7 are measured for a 5s exposure of 1.07 μm light focused to a spot size with 1/e2 diameter of 830 μm or 1044 μm, following the International Organization for Standardization standards.\",\"PeriodicalId\":202227,\"journal\":{\"name\":\"Laser Damage\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laser Damage\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2572934\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laser Damage","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2572934","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Continuous wave laser induced damage threshold of AMTIR-1, 2, 5 and 7 chalcogenide windows at 1.07 microns
The continuous wave laser-induced damage thresholds of Amorphous Materials chalcogenide glasses, Amorphous Materials AMTIR-1, AMTIR-2, AMTIR-5, and AMTIR-7 are measured for a 5s exposure of 1.07 μm light focused to a spot size with 1/e2 diameter of 830 μm or 1044 μm, following the International Organization for Standardization standards.