基于VSC-HVDC线路集成的4型风力发电系统的稳定性与故障漂移分析

C. Kumar, T. V. Kumar
{"title":"基于VSC-HVDC线路集成的4型风力发电系统的稳定性与故障漂移分析","authors":"C. Kumar, T. V. Kumar","doi":"10.11591/IJAPE.V7.I1.PP52-58","DOIUrl":null,"url":null,"abstract":"Now-a-days pollution is increasing due to “Non Renewable Energy Sources”. In order to enhance the efficiency of conventional grid and to generate the electrical power in eco-friendly way, the renewable energy sources are employed.  In this paper a type 4 wind generation system is implemented to analyse the system under fault conditions and to analyse the grid stability. In the proposed system type-4 wind generation system integrated to grid through VSC-HVDC link analysis is done by considering a fault on the grid side by the system gets isolated and wind generation system transfers voltage to local load and remote load. When a DC fault is occurred on the VSC-HVDC link then the grid side breaker and wind side breaker gets open, then system gets isolated. This is implemented by considering “Low Voltage Ride Through” (LVRT) conditions, According to the Indian grid code of contact wind generation maintain constant even the voltage collapse is occurred on the grid side. The proposed VSC-HVDC based Type-4 Wind Generation System give more reliable to operate in LVRT condition and can meet the Load demand when the system is under fault condition to some extent; The proposed method is Type –4 Wind generator is of 4.4MW/2.2kV each with a total plant capacity of 110MW operated with VSC based HVDC transmission system with 110kV DC bus voltage connected to 220kV grid. The results obtained shows the Grid is operates under fault ride through conditions stability.","PeriodicalId":280098,"journal":{"name":"International Journal of Applied Power Engineering","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A Novel on Stability and Fault Ride through Analysis of Type-4 Wind Generation System Integrated to VSC-HVDC Link\",\"authors\":\"C. Kumar, T. V. Kumar\",\"doi\":\"10.11591/IJAPE.V7.I1.PP52-58\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Now-a-days pollution is increasing due to “Non Renewable Energy Sources”. In order to enhance the efficiency of conventional grid and to generate the electrical power in eco-friendly way, the renewable energy sources are employed.  In this paper a type 4 wind generation system is implemented to analyse the system under fault conditions and to analyse the grid stability. In the proposed system type-4 wind generation system integrated to grid through VSC-HVDC link analysis is done by considering a fault on the grid side by the system gets isolated and wind generation system transfers voltage to local load and remote load. When a DC fault is occurred on the VSC-HVDC link then the grid side breaker and wind side breaker gets open, then system gets isolated. This is implemented by considering “Low Voltage Ride Through” (LVRT) conditions, According to the Indian grid code of contact wind generation maintain constant even the voltage collapse is occurred on the grid side. The proposed VSC-HVDC based Type-4 Wind Generation System give more reliable to operate in LVRT condition and can meet the Load demand when the system is under fault condition to some extent; The proposed method is Type –4 Wind generator is of 4.4MW/2.2kV each with a total plant capacity of 110MW operated with VSC based HVDC transmission system with 110kV DC bus voltage connected to 220kV grid. The results obtained shows the Grid is operates under fault ride through conditions stability.\",\"PeriodicalId\":280098,\"journal\":{\"name\":\"International Journal of Applied Power Engineering\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Power Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11591/IJAPE.V7.I1.PP52-58\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/IJAPE.V7.I1.PP52-58","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

如今,由于“不可再生能源”,污染正在增加。为了提高传统电网的效率,并以环保的方式发电,采用了可再生能源。本文以某4型风力发电系统为例,分析了该系统在故障条件下的运行情况,并对电网的稳定性进行了分析。在本文提出的系统中,考虑到系统隔离时电网侧出现故障,风力发电系统向本地负荷和远程负荷传递电压,对通过vdc - hvdc并网的4型风力发电系统进行了链路分析。当直流故障发生时,电网侧断路器和风侧断路器同时断开,系统被隔离。这是通过考虑“低电压穿越”(LVRT)条件来实现的,根据印度电网规范,即使电网侧发生电压崩溃,接触风力发电也保持恒定。所提出的基于VSC-HVDC的四型风力发电系统在LVRT工况下运行更加可靠,能够在一定程度上满足系统故障工况下的负荷需求;-4型风力发电机每台4.4MW/2.2kV,总装机容量110MW,采用基于VSC的高压直流输电系统,110kV直流母线电压与220kV电网连接。结果表明,该电网在故障穿越条件下运行稳定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Novel on Stability and Fault Ride through Analysis of Type-4 Wind Generation System Integrated to VSC-HVDC Link
Now-a-days pollution is increasing due to “Non Renewable Energy Sources”. In order to enhance the efficiency of conventional grid and to generate the electrical power in eco-friendly way, the renewable energy sources are employed.  In this paper a type 4 wind generation system is implemented to analyse the system under fault conditions and to analyse the grid stability. In the proposed system type-4 wind generation system integrated to grid through VSC-HVDC link analysis is done by considering a fault on the grid side by the system gets isolated and wind generation system transfers voltage to local load and remote load. When a DC fault is occurred on the VSC-HVDC link then the grid side breaker and wind side breaker gets open, then system gets isolated. This is implemented by considering “Low Voltage Ride Through” (LVRT) conditions, According to the Indian grid code of contact wind generation maintain constant even the voltage collapse is occurred on the grid side. The proposed VSC-HVDC based Type-4 Wind Generation System give more reliable to operate in LVRT condition and can meet the Load demand when the system is under fault condition to some extent; The proposed method is Type –4 Wind generator is of 4.4MW/2.2kV each with a total plant capacity of 110MW operated with VSC based HVDC transmission system with 110kV DC bus voltage connected to 220kV grid. The results obtained shows the Grid is operates under fault ride through conditions stability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Squirrel Cage Induction Motor Predictive Direct Torque Control based on multi-step delay compensation Power quality improvement using a shunt active power filter based on an cascaded H-bridge eleven level inverter with predictive current control Calculation and measurement of ampacity for class 5 flexible aluminum cable at 110 °C Problems and analysis directions in smart grid technology and their potential solutions Performance enhancement of shunt active power filter using soft computing techniques
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1