哈科特港河河州立大学医学检验专业本科生中某些凝血参数的水平

E. Eze
{"title":"哈科特港河河州立大学医学检验专业本科生中某些凝血参数的水平","authors":"E. Eze","doi":"10.59708/ajlhts.v2i2.2311","DOIUrl":null,"url":null,"abstract":"Introduction: Prothrombin time (PT), International normalized ratio (INR) and activated partial thromboplastin time (APTT) are screening tests used to evaluate the overall integrity of the intrinsic, extrinsic and common coagulation pathway as well as monitoring and management of coagulation disorders. This study was aimed at assessing the PT, INR and APTT among apparently healthy undergraduate Medical Laboratory Science students of Rivers State University, Port Harcourt. Materials and Methods: A total of 100 apparently healthy undergraduate Medical Laboratory Science students of Rivers State University, Port Harcourt comprising of 44 males and 56 females within the age range of 17-40 years were recruited for this study. Five milliliters (5ml) of venous blood was collected from each participant using a standard venipuncture technique into a vacutainer bottle containing 3.2% tri-sodium citrate anticoagulant in a ratio of 1:9 of the anticoagulant and the blood and mixed thoroughly. Prothrombin time and activated partial thromboplastin time were determined by clotting method using the Helena C4 semi-automated, photo-optical coagulation analyzer and the Agappe thromboplastin test kit manufactured by Agappe Diagnostics Switzerland while INR was calculated by using the ratio of the study subjects’ PT to the mean of control PT raised to the power of the reagent international sensitivity index (ISI). The data obtained was analyzed using Graphpad Prism Software version 6.00. Data was presented as means, median, range and standard deviation. Results: The mean ± SD of the PT, INR and APTT were 12.9± 1.624s, 1.01±0.1281 and 37.99±8.898s in the same order. The reference intervals obtained for PT, INR and APTT were 9.7-16.2s, 0.8-1.3 and APTT 20.2-55.8s in the same order. The lower limits were within the ranges established by previous researchers while the upper limits were higher. The age range 21-25 had the highest frequency count (54), which was followed by <20 (26), 26-30 (17) and then <30 (3). The overall mean values for the age groups were within the established normal values and as such no statistically significant difference was observed between the various groups. Conclusion: This study has established the mean values and reference intervals of PT, INR and APTT for apparently healthy Medical Laboratory Science undergraduate students of Rivers State University, Port Harcourt as well as established that age does not have any significant effect on PT, INR and APTT. Due to geography, lifestyle, and genetic diversity, it is recommended that each laboratory establishes geography-specific reference intervals for PT, INR and APTT.","PeriodicalId":380612,"journal":{"name":"African Journal of Laboratory Haematology and Transfusion Science","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Levels of some coagulation parameters among apparently healthy Medical Laboratory Science undergraduate students of Rivers State University, Port Harcourt\",\"authors\":\"E. Eze\",\"doi\":\"10.59708/ajlhts.v2i2.2311\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Prothrombin time (PT), International normalized ratio (INR) and activated partial thromboplastin time (APTT) are screening tests used to evaluate the overall integrity of the intrinsic, extrinsic and common coagulation pathway as well as monitoring and management of coagulation disorders. This study was aimed at assessing the PT, INR and APTT among apparently healthy undergraduate Medical Laboratory Science students of Rivers State University, Port Harcourt. Materials and Methods: A total of 100 apparently healthy undergraduate Medical Laboratory Science students of Rivers State University, Port Harcourt comprising of 44 males and 56 females within the age range of 17-40 years were recruited for this study. Five milliliters (5ml) of venous blood was collected from each participant using a standard venipuncture technique into a vacutainer bottle containing 3.2% tri-sodium citrate anticoagulant in a ratio of 1:9 of the anticoagulant and the blood and mixed thoroughly. Prothrombin time and activated partial thromboplastin time were determined by clotting method using the Helena C4 semi-automated, photo-optical coagulation analyzer and the Agappe thromboplastin test kit manufactured by Agappe Diagnostics Switzerland while INR was calculated by using the ratio of the study subjects’ PT to the mean of control PT raised to the power of the reagent international sensitivity index (ISI). The data obtained was analyzed using Graphpad Prism Software version 6.00. Data was presented as means, median, range and standard deviation. Results: The mean ± SD of the PT, INR and APTT were 12.9± 1.624s, 1.01±0.1281 and 37.99±8.898s in the same order. The reference intervals obtained for PT, INR and APTT were 9.7-16.2s, 0.8-1.3 and APTT 20.2-55.8s in the same order. The lower limits were within the ranges established by previous researchers while the upper limits were higher. The age range 21-25 had the highest frequency count (54), which was followed by <20 (26), 26-30 (17) and then <30 (3). The overall mean values for the age groups were within the established normal values and as such no statistically significant difference was observed between the various groups. Conclusion: This study has established the mean values and reference intervals of PT, INR and APTT for apparently healthy Medical Laboratory Science undergraduate students of Rivers State University, Port Harcourt as well as established that age does not have any significant effect on PT, INR and APTT. Due to geography, lifestyle, and genetic diversity, it is recommended that each laboratory establishes geography-specific reference intervals for PT, INR and APTT.\",\"PeriodicalId\":380612,\"journal\":{\"name\":\"African Journal of Laboratory Haematology and Transfusion Science\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African Journal of Laboratory Haematology and Transfusion Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.59708/ajlhts.v2i2.2311\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Laboratory Haematology and Transfusion Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.59708/ajlhts.v2i2.2311","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

导语:凝血酶原时间(PT),国际标准化比率(INR)和活化部分凝血活素时间(APTT)是用于评估内在,外在和共同凝血途径的整体完整性以及凝血障碍的监测和管理的筛选试验。本研究旨在评估哈考特港河河州立大学医学检验专业本科生表面健康的PT、INR和APTT。材料与方法:选取哈考特港河州州立大学医学检验专业本科生100名,其中男44名,女56名,年龄17-40岁。使用标准静脉穿刺技术从每位参与者身上采集5毫升静脉血,将其放入含有3.2%柠檬酸三钠抗凝剂的真空瓶中,抗凝剂与血液的比例为1:9,并充分混合。凝血酶原时间和活化部分凝血活素时间采用凝血法测定,采用Helena C4半自动化光光学凝血分析仪和Agappe瑞士Agappe诊断公司生产的Agappe凝血活素检测试剂盒,INR采用研究对象PT与对照PT均值之比提高到试剂国际敏感性指数(ISI)的倍数计算。使用Graphpad Prism软件6.00版对所得数据进行分析。数据以平均值、中位数、极差和标准差表示。结果:PT、INR、APTT的平均±SD依次为12.9±1.624s、1.01±0.1281 s、37.99±8.898s。PT、INR和APTT的参考区间依次为9.7 ~ 16.s、0.8 ~ 1.3和20.2 ~ 55.8s。下限在前人研究确定的范围内,上限较高。21 ~ 25岁频率数最多(54),其次为<20(26)、26 ~ 30(17)、<30(3)。各年龄组总体平均值均在正常范围内,各组间无统计学差异。结论:本研究建立了哈考特港河州立大学医学检验专业本科学生PT、INR和APTT的平均值和参考区间,年龄对PT、INR和APTT无显著影响。由于地理,生活方式和遗传多样性,建议每个实验室建立PT, INR和APTT的地理特定参考区间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Levels of some coagulation parameters among apparently healthy Medical Laboratory Science undergraduate students of Rivers State University, Port Harcourt
Introduction: Prothrombin time (PT), International normalized ratio (INR) and activated partial thromboplastin time (APTT) are screening tests used to evaluate the overall integrity of the intrinsic, extrinsic and common coagulation pathway as well as monitoring and management of coagulation disorders. This study was aimed at assessing the PT, INR and APTT among apparently healthy undergraduate Medical Laboratory Science students of Rivers State University, Port Harcourt. Materials and Methods: A total of 100 apparently healthy undergraduate Medical Laboratory Science students of Rivers State University, Port Harcourt comprising of 44 males and 56 females within the age range of 17-40 years were recruited for this study. Five milliliters (5ml) of venous blood was collected from each participant using a standard venipuncture technique into a vacutainer bottle containing 3.2% tri-sodium citrate anticoagulant in a ratio of 1:9 of the anticoagulant and the blood and mixed thoroughly. Prothrombin time and activated partial thromboplastin time were determined by clotting method using the Helena C4 semi-automated, photo-optical coagulation analyzer and the Agappe thromboplastin test kit manufactured by Agappe Diagnostics Switzerland while INR was calculated by using the ratio of the study subjects’ PT to the mean of control PT raised to the power of the reagent international sensitivity index (ISI). The data obtained was analyzed using Graphpad Prism Software version 6.00. Data was presented as means, median, range and standard deviation. Results: The mean ± SD of the PT, INR and APTT were 12.9± 1.624s, 1.01±0.1281 and 37.99±8.898s in the same order. The reference intervals obtained for PT, INR and APTT were 9.7-16.2s, 0.8-1.3 and APTT 20.2-55.8s in the same order. The lower limits were within the ranges established by previous researchers while the upper limits were higher. The age range 21-25 had the highest frequency count (54), which was followed by <20 (26), 26-30 (17) and then <30 (3). The overall mean values for the age groups were within the established normal values and as such no statistically significant difference was observed between the various groups. Conclusion: This study has established the mean values and reference intervals of PT, INR and APTT for apparently healthy Medical Laboratory Science undergraduate students of Rivers State University, Port Harcourt as well as established that age does not have any significant effect on PT, INR and APTT. Due to geography, lifestyle, and genetic diversity, it is recommended that each laboratory establishes geography-specific reference intervals for PT, INR and APTT.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Full blood count and some haemorheologic variables of vendors exposed to liquefied petroleum (cooking) gas: a comparative study Frequencies of blood donation and types of blood donors on storage lesions as assessed by antioxidants and lipid peroxidation levels Levels of some coagulation parameters among apparently healthy Medical Laboratory Science undergraduate students of Rivers State University, Port Harcourt PREVALENCE OF COVID-19 INFECTION AMONG OUTPATIENTS ATTENDING A NIGERIAN TERTIARY HOSPITAL Haemolysin test, ABO and Rhesus Blood grouping in Relation to occurrence of stillbirth, Miscarriage and transfusion status among Pregnant Women in University of Calabar, Nigeria
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1