基于D-STATCOM的并网太阳能光伏(GCPV)系统建模提高系统稳定性

Hana Munirah Abd. Rashid, S. A. Jumaat, Siti Haiar Nabila Yusof, S. A. Zulkifli
{"title":"基于D-STATCOM的并网太阳能光伏(GCPV)系统建模提高系统稳定性","authors":"Hana Munirah Abd. Rashid, S. A. Jumaat, Siti Haiar Nabila Yusof, S. A. Zulkifli","doi":"10.1109/ICPEA53519.2022.9744640","DOIUrl":null,"url":null,"abstract":"The purpose of this research is to model and simulate 100 kW solar PV systems that are connected to the utility distribution system with and without Distribution Static Synchronous Compensator (D-STATCOM) and Dynamic Voltage Restorer (DVR) under normal and faults condition in MATLAB/ Simulink. The test systems consist of a PV array that is connected in series and parallel modules, a DC-DC Boost Converter, Maximum Power Point Tracking (MPPT) control, DC-AC inverter, inverter control, filter, three-phase load, distribution transformer, and grid equipment. The grid operates test systems at the nominal three-phase line to line voltage of 260 V, supplied from 100 kVA 25/0.26 kV distribution transformer. The simulation results showed that the installation of D-STATCOM and DVR in GCPV systems improved 80-90% of the output power from the PV systems. The implementation of D-FACTS devices in GCPV systems will be beneficial for future power system stability studies in the distribution system.","PeriodicalId":371063,"journal":{"name":"2022 IEEE International Conference in Power Engineering Application (ICPEA)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modeling the Grid Connected Solar PV (GCPV) System with D-STATCOM to Improve Stability System\",\"authors\":\"Hana Munirah Abd. Rashid, S. A. Jumaat, Siti Haiar Nabila Yusof, S. A. Zulkifli\",\"doi\":\"10.1109/ICPEA53519.2022.9744640\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this research is to model and simulate 100 kW solar PV systems that are connected to the utility distribution system with and without Distribution Static Synchronous Compensator (D-STATCOM) and Dynamic Voltage Restorer (DVR) under normal and faults condition in MATLAB/ Simulink. The test systems consist of a PV array that is connected in series and parallel modules, a DC-DC Boost Converter, Maximum Power Point Tracking (MPPT) control, DC-AC inverter, inverter control, filter, three-phase load, distribution transformer, and grid equipment. The grid operates test systems at the nominal three-phase line to line voltage of 260 V, supplied from 100 kVA 25/0.26 kV distribution transformer. The simulation results showed that the installation of D-STATCOM and DVR in GCPV systems improved 80-90% of the output power from the PV systems. The implementation of D-FACTS devices in GCPV systems will be beneficial for future power system stability studies in the distribution system.\",\"PeriodicalId\":371063,\"journal\":{\"name\":\"2022 IEEE International Conference in Power Engineering Application (ICPEA)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE International Conference in Power Engineering Application (ICPEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPEA53519.2022.9744640\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference in Power Engineering Application (ICPEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEA53519.2022.9744640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是在MATLAB/ Simulink中对100 kW的太阳能光伏系统在正常和故障情况下进行建模和仿真,该系统与公用事业配电系统连接,有和没有配电静态同步补偿器(D-STATCOM)和动态电压恢复器(DVR)。测试系统由串联和并联模块连接的光伏阵列、DC-DC升压变换器、最大功率点跟踪(MPPT)控制、DC-AC逆变器、逆变器控制、滤波器、三相负载、配电变压器和电网设备组成。电网运行测试系统的标称三相线对线电压为260 V,由100 kVA 25/0.26 kV配电变压器供电。仿真结果表明,在GCPV系统中安装D-STATCOM和DVR可使光伏系统输出功率提高80-90%。D-FACTS装置在GCPV系统中的应用将有利于今后配电系统稳定性的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Modeling the Grid Connected Solar PV (GCPV) System with D-STATCOM to Improve Stability System
The purpose of this research is to model and simulate 100 kW solar PV systems that are connected to the utility distribution system with and without Distribution Static Synchronous Compensator (D-STATCOM) and Dynamic Voltage Restorer (DVR) under normal and faults condition in MATLAB/ Simulink. The test systems consist of a PV array that is connected in series and parallel modules, a DC-DC Boost Converter, Maximum Power Point Tracking (MPPT) control, DC-AC inverter, inverter control, filter, three-phase load, distribution transformer, and grid equipment. The grid operates test systems at the nominal three-phase line to line voltage of 260 V, supplied from 100 kVA 25/0.26 kV distribution transformer. The simulation results showed that the installation of D-STATCOM and DVR in GCPV systems improved 80-90% of the output power from the PV systems. The implementation of D-FACTS devices in GCPV systems will be beneficial for future power system stability studies in the distribution system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Investigation on Total Harmonics Distortion for Transistor Clamped Cascaded H-Bridge Multilevel Inverter Using Newton-Raphson Method An Efficient Holomorphic Based Available Transfer Capability Solution in Presence of Large Scale Wind Farms Analysis of Radial Distribution Test Feeders in Presence of Solar Photovoltaic Systems Using PowerFactory Occurrence of Positive Cloud-to-Ground Lightning During Flash Flood in Malacca Investigation of Aerodynamics for Third Rail on Regenerative Braking Energy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1