蒸压加气混凝土隔热对单户住宅能源性能的影响

I. Kirakevych, M. Sanytsky, Danylo Kotur
{"title":"蒸压加气混凝土隔热对单户住宅能源性能的影响","authors":"I. Kirakevych, M. Sanytsky, Danylo Kotur","doi":"10.23939/jtbp2023.01.043","DOIUrl":null,"url":null,"abstract":"The article examines the effect of thermal insulation from autoclaved aerated concrete on the energy characteristics of a single-family house. Analysis of mathematical models of energy characteristics of external enclosing structures of buildings depending on the thickness of AEROC autoclaved concrete products according to the criteria of heat loss shows that the thermal resistance value of 7.11 m2K/W and the heat transfer coefficient of 0.141 W/(m2K) are achieved using the wall block AEROC D 300 and AEROC Energy thermal insulation panel with a thickness of 200 mm. These indicators correspond to the passive house standard for thermal resistance (Ro ≥ 6.7 m2K/W) and heat transfer coefficient (Uo ≤ 0.15 W/m2K) of external walls, which confirms the feasibility of using AEROC Energy D 150 thermal insulation panels in combination with wall blocks AEROC D 300 for housing construction according to passive construction standards.","PeriodicalId":369033,"journal":{"name":"Theory and Building Practice","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effect of thermal insulation from autoclaved aerated concrete on the energy performance of a single-family house\",\"authors\":\"I. Kirakevych, M. Sanytsky, Danylo Kotur\",\"doi\":\"10.23939/jtbp2023.01.043\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article examines the effect of thermal insulation from autoclaved aerated concrete on the energy characteristics of a single-family house. Analysis of mathematical models of energy characteristics of external enclosing structures of buildings depending on the thickness of AEROC autoclaved concrete products according to the criteria of heat loss shows that the thermal resistance value of 7.11 m2K/W and the heat transfer coefficient of 0.141 W/(m2K) are achieved using the wall block AEROC D 300 and AEROC Energy thermal insulation panel with a thickness of 200 mm. These indicators correspond to the passive house standard for thermal resistance (Ro ≥ 6.7 m2K/W) and heat transfer coefficient (Uo ≤ 0.15 W/m2K) of external walls, which confirms the feasibility of using AEROC Energy D 150 thermal insulation panels in combination with wall blocks AEROC D 300 for housing construction according to passive construction standards.\",\"PeriodicalId\":369033,\"journal\":{\"name\":\"Theory and Building Practice\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Theory and Building Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23939/jtbp2023.01.043\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Theory and Building Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23939/jtbp2023.01.043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文考察了保温效果从蒸压加气混凝土对单户住宅的能源特性。根据热损失准则对AEROC蒸压混凝土产品厚度对建筑围护结构能量特性影响的数学模型进行分析,结果表明,采用AEROC D 300墙体砌块和厚度为200 mm的AEROC能量保温板,其热阻值为7.11 m2K/W,换热系数为0.141 W/(m2K)。这些指标符合被动式房屋外墙热阻(Ro≥6.7 m2K/W)和传热系数(Uo≤0.15 W/m2K)标准,证实了按照被动式建筑标准,采用AEROC Energy D 150绝热板结合墙块AEROC D 300进行房屋施工的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The effect of thermal insulation from autoclaved aerated concrete on the energy performance of a single-family house
The article examines the effect of thermal insulation from autoclaved aerated concrete on the energy characteristics of a single-family house. Analysis of mathematical models of energy characteristics of external enclosing structures of buildings depending on the thickness of AEROC autoclaved concrete products according to the criteria of heat loss shows that the thermal resistance value of 7.11 m2K/W and the heat transfer coefficient of 0.141 W/(m2K) are achieved using the wall block AEROC D 300 and AEROC Energy thermal insulation panel with a thickness of 200 mm. These indicators correspond to the passive house standard for thermal resistance (Ro ≥ 6.7 m2K/W) and heat transfer coefficient (Uo ≤ 0.15 W/m2K) of external walls, which confirms the feasibility of using AEROC Energy D 150 thermal insulation panels in combination with wall blocks AEROC D 300 for housing construction according to passive construction standards.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
INJECTION OF CRACKS IN A RC BEAM WITH EPOXY RESIN USING THE GRAVITY FLOW METHOD OVER-STABILIZED BITUMEN EMULSIONS MADE FROM EMULSIFIERS FOR SLOW-SETTING EMULSIONS METHOD OF ARRANGEMENT OF INTERNAL THERMAL INSULATION OF EXTERNAL PROTECTIVE STRUCTURES OF THE ROOM STUDY OF FINE-GRAINED FIBER CONCRETE CRACKING RESISTANCE FROM THE POINT OF VIEW OF DESTRUCTION MECHANICS CONCRETE ON QUARTZITE AGGREGATES
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1