{"title":"干燥室内温度与相对湿度的耦合分析与控制","authors":"Hong Ma, Wei Zhang, Simon X. Yang","doi":"10.1109/ICINFA.2013.6720509","DOIUrl":null,"url":null,"abstract":"This paper analyzes the coupling influence of temperature and relative humidity in a meat-drying room, and its resulting excessive energy consumption. This coupling influence is shown to require a practical control system that decouples the two factors. Analysis of temperature disturbance and evaluation of energy consumption are presented. The application of steady-state temperature and relative humidity control system improvement and the resulting performance and energy savings are discussed.","PeriodicalId":250844,"journal":{"name":"2013 IEEE International Conference on Information and Automation (ICIA)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Coupling analysis and control of temperature and relative humidity in a drying room\",\"authors\":\"Hong Ma, Wei Zhang, Simon X. Yang\",\"doi\":\"10.1109/ICINFA.2013.6720509\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper analyzes the coupling influence of temperature and relative humidity in a meat-drying room, and its resulting excessive energy consumption. This coupling influence is shown to require a practical control system that decouples the two factors. Analysis of temperature disturbance and evaluation of energy consumption are presented. The application of steady-state temperature and relative humidity control system improvement and the resulting performance and energy savings are discussed.\",\"PeriodicalId\":250844,\"journal\":{\"name\":\"2013 IEEE International Conference on Information and Automation (ICIA)\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Conference on Information and Automation (ICIA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICINFA.2013.6720509\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Information and Automation (ICIA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICINFA.2013.6720509","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Coupling analysis and control of temperature and relative humidity in a drying room
This paper analyzes the coupling influence of temperature and relative humidity in a meat-drying room, and its resulting excessive energy consumption. This coupling influence is shown to require a practical control system that decouples the two factors. Analysis of temperature disturbance and evaluation of energy consumption are presented. The application of steady-state temperature and relative humidity control system improvement and the resulting performance and energy savings are discussed.