最近的结果与CdTe成像门静脉扫描仪放射治疗

G. Entine, R. Redus, A. Feyder, P. Biggs
{"title":"最近的结果与CdTe成像门静脉扫描仪放射治疗","authors":"G. Entine, R. Redus, A. Feyder, P. Biggs","doi":"10.1109/NSSMIC.1992.301535","DOIUrl":null,"url":null,"abstract":"A prototype portal imager has been constructed using a linear array of 256 CdTe photovoltaic detectors, each 2*2*2 mm. The array is attached to a compact linear scanner which is to be mounted in a cassette-shaped package located below the patient table. The array of detectors is moved under the patient during image acquisition. The high stopping power of CdTe allows a high-contrast image to be made using a single linac pulse for each array position. In tests conducted with a 4 MV linac, this system produced 50 cm*35 cm near-real-time images with an open field signal-to-noise ratio (SNR) of 143 and 2 mm spatial resolution in less than three seconds. This corresponds to a SNR of 1 for 1% contrast objects. Ultimately, a SNR greater than 5 at 1% contrast should be achievable with no loss of spatial resolution or increase in acquisition time.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"Recent results with a CdTe imaging portal scanner for radiation therapy\",\"authors\":\"G. Entine, R. Redus, A. Feyder, P. Biggs\",\"doi\":\"10.1109/NSSMIC.1992.301535\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A prototype portal imager has been constructed using a linear array of 256 CdTe photovoltaic detectors, each 2*2*2 mm. The array is attached to a compact linear scanner which is to be mounted in a cassette-shaped package located below the patient table. The array of detectors is moved under the patient during image acquisition. The high stopping power of CdTe allows a high-contrast image to be made using a single linac pulse for each array position. In tests conducted with a 4 MV linac, this system produced 50 cm*35 cm near-real-time images with an open field signal-to-noise ratio (SNR) of 143 and 2 mm spatial resolution in less than three seconds. This corresponds to a SNR of 1 for 1% contrast objects. Ultimately, a SNR greater than 5 at 1% contrast should be achievable with no loss of spatial resolution or increase in acquisition time.<<ETX>>\",\"PeriodicalId\":447239,\"journal\":{\"name\":\"IEEE Conference on Nuclear Science Symposium and Medical Imaging\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Conference on Nuclear Science Symposium and Medical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1992.301535\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1992.301535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

摘要

使用256个CdTe光伏探测器线性阵列构建了一个原型门户成像仪,每个探测器为2*2*2 mm。该阵列连接到一个紧凑的线性扫描仪上,该扫描仪将安装在位于患者桌子下方的盒式包装中。在图像采集过程中,检测器阵列在患者下方移动。CdTe的高阻挡能力允许使用单个直线脉冲为每个阵列位置制作高对比度图像。在4 MV直线加速器上进行的测试中,该系统在不到3秒的时间内生成了50 cm*35 cm的近实时图像,开放场信噪比(SNR)为143,空间分辨率为2mm。这对应于1%对比度对象的信噪比为1。最终,在不损失空间分辨率或增加采集时间的情况下,在1%对比度下的信噪比应该大于5。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Recent results with a CdTe imaging portal scanner for radiation therapy
A prototype portal imager has been constructed using a linear array of 256 CdTe photovoltaic detectors, each 2*2*2 mm. The array is attached to a compact linear scanner which is to be mounted in a cassette-shaped package located below the patient table. The array of detectors is moved under the patient during image acquisition. The high stopping power of CdTe allows a high-contrast image to be made using a single linac pulse for each array position. In tests conducted with a 4 MV linac, this system produced 50 cm*35 cm near-real-time images with an open field signal-to-noise ratio (SNR) of 143 and 2 mm spatial resolution in less than three seconds. This corresponds to a SNR of 1 for 1% contrast objects. Ultimately, a SNR greater than 5 at 1% contrast should be achievable with no loss of spatial resolution or increase in acquisition time.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Results in online data processing in the data acquisition system of the ALEPH TPC Practical evaluation of several cone beam orbits for SPECT Model based scatter correction in three dimensions (positron emission tomography) Macintosh software for simulating resolution and scatter effects in PET Testing fast ADC's at sample rates between 20 and 140 MSPS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1