{"title":"基于空间矢量的改进单周期控制三相三线有源滤波器仿真","authors":"Jidong Wang, Meicui Qin, Guanqing Yang","doi":"10.1109/ISGT-ASIA.2012.6303273","DOIUrl":null,"url":null,"abstract":"The combination of space vector and one-cycle control method could make the controller structure much simple in three-phase three-wire active power filter (APF) with one-cycle control method. But in traditional methods, 6 sextants are divided at a frequency cycle in the whole range of space vector area. In this paper, the whole 6 sextants are divided in a novel method and section 1&2, section 3&4, section 5&6 can be merged respectively, and so only 3 sextants are required for the realization of space vector. As a result, the implementation of the controller is much simple. Simulation results show that the proposed method has a good compensation effect and validate the method is feasible and effective.","PeriodicalId":330758,"journal":{"name":"IEEE PES Innovative Smart Grid Technologies","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Simulation of three-phase three-wire APF with modified one-cycle control based on space vector\",\"authors\":\"Jidong Wang, Meicui Qin, Guanqing Yang\",\"doi\":\"10.1109/ISGT-ASIA.2012.6303273\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The combination of space vector and one-cycle control method could make the controller structure much simple in three-phase three-wire active power filter (APF) with one-cycle control method. But in traditional methods, 6 sextants are divided at a frequency cycle in the whole range of space vector area. In this paper, the whole 6 sextants are divided in a novel method and section 1&2, section 3&4, section 5&6 can be merged respectively, and so only 3 sextants are required for the realization of space vector. As a result, the implementation of the controller is much simple. Simulation results show that the proposed method has a good compensation effect and validate the method is feasible and effective.\",\"PeriodicalId\":330758,\"journal\":{\"name\":\"IEEE PES Innovative Smart Grid Technologies\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE PES Innovative Smart Grid Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGT-ASIA.2012.6303273\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-ASIA.2012.6303273","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Simulation of three-phase three-wire APF with modified one-cycle control based on space vector
The combination of space vector and one-cycle control method could make the controller structure much simple in three-phase three-wire active power filter (APF) with one-cycle control method. But in traditional methods, 6 sextants are divided at a frequency cycle in the whole range of space vector area. In this paper, the whole 6 sextants are divided in a novel method and section 1&2, section 3&4, section 5&6 can be merged respectively, and so only 3 sextants are required for the realization of space vector. As a result, the implementation of the controller is much simple. Simulation results show that the proposed method has a good compensation effect and validate the method is feasible and effective.