基于miRNA-128的急性淋巴细胞白血病(ALL)诊断纳米传感器的设计

Negar Naderian, Mehrab Pourmadadi, H. Rashedi, F. Yazdian
{"title":"基于miRNA-128的急性淋巴细胞白血病(ALL)诊断纳米传感器的设计","authors":"Negar Naderian, Mehrab Pourmadadi, H. Rashedi, F. Yazdian","doi":"10.1109/ICBME51989.2020.9319427","DOIUrl":null,"url":null,"abstract":"In this work, an aptamer-based electrochemical nano biosensor has been designed that is effective in the early detection of Acute Lymphoid Leukemia (ALL) by microRNA-128 in blood serum samples. In the design of this nanoprobe, Graphitic Carbon Nitride (G-C3N4) has been used. Urea at high temperature is used to prepare graphitic carbon nitride. G-C3N4 has a modifiable surface that can carry metals, so gold nanoparticles were placed on its sheets. Consequently, the resulted nanocomposite obtained a high surface-to-volume ratio and much higher conductivity for aptamer binding. The synthesis method of this nanocomposite is Green using vitamin C and is biocompatible. In this study, electrochemical characterization tests, X-ray diffraction (XRD) and Fourier transform infrared (FTIR) tests and transmission electron microscopy (TEM) technique were used. The Limit Of Detection (LOD) of the nano biosensor was obtained about 0.0034 fM in square wave voltammetry (SWV). It was obtained by performing tests at different concentrations of the analyte for three times. Compared with the other works, this limit of detection is much lower and shows the high ability of the nanobiosensor to early detection of Acute Lymphoid Leukemia. Also, the designed biosensor needed a short time (about 45 minutes) to detect the miRNA-128 as symptoms of the disease. It is the first time that Au/G-C3N4 nanocomposite and this aptamer sequence are used in a biosensor together for gene detection (miRNA-128) as an electrochemical biosensor for diagnosis of acute lymphoid leukemia.","PeriodicalId":120969,"journal":{"name":"2020 27th National and 5th International Iranian Conference on Biomedical Engineering (ICBME)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Design of a Novel Nanobiosensor for the Diagnosis of Acute Lymphoid Leukemia (ALL) by Measurement of miRNA-128\",\"authors\":\"Negar Naderian, Mehrab Pourmadadi, H. Rashedi, F. Yazdian\",\"doi\":\"10.1109/ICBME51989.2020.9319427\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, an aptamer-based electrochemical nano biosensor has been designed that is effective in the early detection of Acute Lymphoid Leukemia (ALL) by microRNA-128 in blood serum samples. In the design of this nanoprobe, Graphitic Carbon Nitride (G-C3N4) has been used. Urea at high temperature is used to prepare graphitic carbon nitride. G-C3N4 has a modifiable surface that can carry metals, so gold nanoparticles were placed on its sheets. Consequently, the resulted nanocomposite obtained a high surface-to-volume ratio and much higher conductivity for aptamer binding. The synthesis method of this nanocomposite is Green using vitamin C and is biocompatible. In this study, electrochemical characterization tests, X-ray diffraction (XRD) and Fourier transform infrared (FTIR) tests and transmission electron microscopy (TEM) technique were used. The Limit Of Detection (LOD) of the nano biosensor was obtained about 0.0034 fM in square wave voltammetry (SWV). It was obtained by performing tests at different concentrations of the analyte for three times. Compared with the other works, this limit of detection is much lower and shows the high ability of the nanobiosensor to early detection of Acute Lymphoid Leukemia. Also, the designed biosensor needed a short time (about 45 minutes) to detect the miRNA-128 as symptoms of the disease. It is the first time that Au/G-C3N4 nanocomposite and this aptamer sequence are used in a biosensor together for gene detection (miRNA-128) as an electrochemical biosensor for diagnosis of acute lymphoid leukemia.\",\"PeriodicalId\":120969,\"journal\":{\"name\":\"2020 27th National and 5th International Iranian Conference on Biomedical Engineering (ICBME)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 27th National and 5th International Iranian Conference on Biomedical Engineering (ICBME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBME51989.2020.9319427\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 27th National and 5th International Iranian Conference on Biomedical Engineering (ICBME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBME51989.2020.9319427","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在这项工作中,设计了一种基于适配体的电化学纳米生物传感器,可以有效地通过血清样本中的microRNA-128早期检测急性淋巴细胞白血病(ALL)。在这种纳米探针的设计中,使用了石墨化碳氮化(G-C3N4)。用尿素在高温下制备石墨化氮化碳。G-C3N4具有可修饰的表面,可以携带金属,因此金纳米颗粒被放置在其薄片上。因此,所得到的纳米复合材料获得了高的表面体积比和更高的适体结合电导率。该纳米复合材料的合成方法是绿色的,使用维生素C,具有生物相容性。本研究采用电化学表征、x射线衍射(XRD)、傅里叶变换红外(FTIR)测试和透射电子显微镜(TEM)技术。在方波伏安法(SWV)下,纳米生物传感器的检出限(LOD)约为0.0034 fM。它是通过在不同浓度的分析物中进行三次测试得到的。与其他工作相比,这一检测限大大降低,表明纳米生物传感器对急性淋巴细胞白血病的早期检测能力强。此外,设计的生物传感器需要很短的时间(约45分钟)来检测miRNA-128作为疾病的症状。这是首次将Au/G-C3N4纳米复合物与该适体序列一起应用于基因检测生物传感器(miRNA-128)中,作为诊断急性淋巴细胞白血病的电化学生物传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design of a Novel Nanobiosensor for the Diagnosis of Acute Lymphoid Leukemia (ALL) by Measurement of miRNA-128
In this work, an aptamer-based electrochemical nano biosensor has been designed that is effective in the early detection of Acute Lymphoid Leukemia (ALL) by microRNA-128 in blood serum samples. In the design of this nanoprobe, Graphitic Carbon Nitride (G-C3N4) has been used. Urea at high temperature is used to prepare graphitic carbon nitride. G-C3N4 has a modifiable surface that can carry metals, so gold nanoparticles were placed on its sheets. Consequently, the resulted nanocomposite obtained a high surface-to-volume ratio and much higher conductivity for aptamer binding. The synthesis method of this nanocomposite is Green using vitamin C and is biocompatible. In this study, electrochemical characterization tests, X-ray diffraction (XRD) and Fourier transform infrared (FTIR) tests and transmission electron microscopy (TEM) technique were used. The Limit Of Detection (LOD) of the nano biosensor was obtained about 0.0034 fM in square wave voltammetry (SWV). It was obtained by performing tests at different concentrations of the analyte for three times. Compared with the other works, this limit of detection is much lower and shows the high ability of the nanobiosensor to early detection of Acute Lymphoid Leukemia. Also, the designed biosensor needed a short time (about 45 minutes) to detect the miRNA-128 as symptoms of the disease. It is the first time that Au/G-C3N4 nanocomposite and this aptamer sequence are used in a biosensor together for gene detection (miRNA-128) as an electrochemical biosensor for diagnosis of acute lymphoid leukemia.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Semi-automatic 3-D pose estimation of laparoscopic tools to generate 3-D labeled database by developing a graphical user interface Children Semantic Network Growth: A Graph Theory Analysis Autistic Children Skill Acquisition In Sport: An Experimental Study A Two-step Registration Approach: Application in MRI-based Strain Calculation of the Left Ventricle The Effect of Stem on The Knee Joint Prosthesis Flexion Considering Natural Gait Forces
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1