分散接地电阻变化对用户运行的影响

S. Abagiu, I. Lepadat, E. Helerea
{"title":"分散接地电阻变化对用户运行的影响","authors":"S. Abagiu, I. Lepadat, E. Helerea","doi":"10.1109/ICATE.2014.6972619","DOIUrl":null,"url":null,"abstract":"Associated phenomena usually to interruption of neutral conductor and to change of the dispersion earth resistance touch a sensitive aspect of low-voltage power networks. Therefore, a tool is needed to evaluate the risks associated with this behaviour. This paper proposes a mathematical model to describe realistic influence of dispersion earth resistance of earth electrode and unbalanced power supply system of the consumer, the phase currents and voltages on the consumer. These phenomena are directly related to the power quality and efficiency of protective system, especially in case of three-phase unbalanced consumers. In this paper it is shown that the neutral displacement voltage, neutral current and phase currents and voltages depend on the severity of the unbalance of three-phase consumer and of the value of three-phase dispersion earth resistance. Simulations are made for consumer operation in case of unbalanced regime with the dispersion earth resistance of earth electrode from downstream of fault location equal to 4 Ω, 2 Ω and 1 Ω. The results are useful for the design and operation of the protective system.","PeriodicalId":327050,"journal":{"name":"2014 International Conference on Applied and Theoretical Electricity (ICATE)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of dispersion earth resistance variation on the consumers operation\",\"authors\":\"S. Abagiu, I. Lepadat, E. Helerea\",\"doi\":\"10.1109/ICATE.2014.6972619\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Associated phenomena usually to interruption of neutral conductor and to change of the dispersion earth resistance touch a sensitive aspect of low-voltage power networks. Therefore, a tool is needed to evaluate the risks associated with this behaviour. This paper proposes a mathematical model to describe realistic influence of dispersion earth resistance of earth electrode and unbalanced power supply system of the consumer, the phase currents and voltages on the consumer. These phenomena are directly related to the power quality and efficiency of protective system, especially in case of three-phase unbalanced consumers. In this paper it is shown that the neutral displacement voltage, neutral current and phase currents and voltages depend on the severity of the unbalance of three-phase consumer and of the value of three-phase dispersion earth resistance. Simulations are made for consumer operation in case of unbalanced regime with the dispersion earth resistance of earth electrode from downstream of fault location equal to 4 Ω, 2 Ω and 1 Ω. The results are useful for the design and operation of the protective system.\",\"PeriodicalId\":327050,\"journal\":{\"name\":\"2014 International Conference on Applied and Theoretical Electricity (ICATE)\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Applied and Theoretical Electricity (ICATE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICATE.2014.6972619\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Applied and Theoretical Electricity (ICATE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICATE.2014.6972619","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

中性点导体断流和色散接地电阻变化等相关现象是低压电网的一个敏感问题。因此,需要一个工具来评估与此行为相关的风险。本文提出了一个数学模型来描述接地电极的色散接地电阻和用户的不平衡供电系统、相电流和电压对用户的实际影响。这些现象直接关系到保护系统的电能质量和效率,特别是在三相不平衡用户的情况下。本文指出,中性点位移电压、中性点电流、相电流和电压取决于三相用户不平衡的严重程度和三相分散接地电阻的值。对故障位置下游接地电极的色散接地电阻分别为4 Ω、2 Ω和1 Ω的不平衡状态下的用户运行进行了模拟。研究结果对保护系统的设计和运行有一定的指导意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of dispersion earth resistance variation on the consumers operation
Associated phenomena usually to interruption of neutral conductor and to change of the dispersion earth resistance touch a sensitive aspect of low-voltage power networks. Therefore, a tool is needed to evaluate the risks associated with this behaviour. This paper proposes a mathematical model to describe realistic influence of dispersion earth resistance of earth electrode and unbalanced power supply system of the consumer, the phase currents and voltages on the consumer. These phenomena are directly related to the power quality and efficiency of protective system, especially in case of three-phase unbalanced consumers. In this paper it is shown that the neutral displacement voltage, neutral current and phase currents and voltages depend on the severity of the unbalance of three-phase consumer and of the value of three-phase dispersion earth resistance. Simulations are made for consumer operation in case of unbalanced regime with the dispersion earth resistance of earth electrode from downstream of fault location equal to 4 Ω, 2 Ω and 1 Ω. The results are useful for the design and operation of the protective system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Conducted emission measurements for a laptop Analysis of implementation opportunities for selected conventional counter-based circuits in selected FPGA structures in terms of time performance The technical progress and its reflection in the construction of the medium voltage metal enclosed switchgear for secondary distribution of electricity The control of an industrial process with PLC A wideband varactor-tuned BICMOS Negative Inductance design
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1