{"title":"确保电气设备在其预期用途中是安全的","authors":"J. Andrews, L. Mcclung, T. J. White","doi":"10.1109/2943.838040","DOIUrl":null,"url":null,"abstract":"The US Occupational Safety and Health Administration (OSHA) regulations, the National Electrical Code (NEC), and several other nationally recognized Standards and Recommended Practices, indicate that electrical equipment must be inspected tested and evaluated to ensure that it is essentially free of hazards. Manufacturer-supplied standard lines containing \"approved\" components and manufacturer-supplied assemblies that are \"listed\" by a \"Nationally Recognized Testing Laboratory (NRTL)\", are acceptable to the OSHA. When no NRTL accepts, certifies, lists or labels a particular piece of equipment, or determines if to be safe, special actions, involving the authority having jurisdiction (AHJ), are required to assure that the equipment complies with regulations. Such equipment would include custom-made one-of-a-kind equipment, equipment made \"in-house\" for research or other special purposes and equipment manufactured outside of the United States. This paper gives guidance towards ensuring that electrical equipment meets the safety intention of present-day regulations, codes and standards.","PeriodicalId":436140,"journal":{"name":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","volume":"108 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Ensuring that electrical equipment is safe for its intended use\",\"authors\":\"J. Andrews, L. Mcclung, T. J. White\",\"doi\":\"10.1109/2943.838040\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The US Occupational Safety and Health Administration (OSHA) regulations, the National Electrical Code (NEC), and several other nationally recognized Standards and Recommended Practices, indicate that electrical equipment must be inspected tested and evaluated to ensure that it is essentially free of hazards. Manufacturer-supplied standard lines containing \\\"approved\\\" components and manufacturer-supplied assemblies that are \\\"listed\\\" by a \\\"Nationally Recognized Testing Laboratory (NRTL)\\\", are acceptable to the OSHA. When no NRTL accepts, certifies, lists or labels a particular piece of equipment, or determines if to be safe, special actions, involving the authority having jurisdiction (AHJ), are required to assure that the equipment complies with regulations. Such equipment would include custom-made one-of-a-kind equipment, equipment made \\\"in-house\\\" for research or other special purposes and equipment manufactured outside of the United States. This paper gives guidance towards ensuring that electrical equipment meets the safety intention of present-day regulations, codes and standards.\",\"PeriodicalId\":436140,\"journal\":{\"name\":\"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)\",\"volume\":\"108 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-05-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/2943.838040\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1998 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record. Papers Presented at the 1998 Annual Meeting (Cat. No.98CH36202)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/2943.838040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

美国职业安全与健康管理局(OSHA)法规、国家电气规范(NEC)以及其他一些国家认可的标准和推荐做法表明,电气设备必须经过检查、测试和评估,以确保其基本上没有危害。制造商提供的标准生产线包含“批准”的组件和制造商提供的组件,并由“国家认可的测试实验室(NRTL)”“列出”,是OSHA可接受的。如果没有NRTL接受、认证、列出或标记特定设备,或确定其是否安全,则需要有管辖权的当局(AHJ)采取特殊行动,以确保设备符合规定。此类设备将包括定制的独一无二的设备,为研究或其他特殊目的“内部”制造的设备以及在美国境外制造的设备。本文为确保电气设备符合现行法规、规范和标准的安全意图提供指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ensuring that electrical equipment is safe for its intended use
The US Occupational Safety and Health Administration (OSHA) regulations, the National Electrical Code (NEC), and several other nationally recognized Standards and Recommended Practices, indicate that electrical equipment must be inspected tested and evaluated to ensure that it is essentially free of hazards. Manufacturer-supplied standard lines containing "approved" components and manufacturer-supplied assemblies that are "listed" by a "Nationally Recognized Testing Laboratory (NRTL)", are acceptable to the OSHA. When no NRTL accepts, certifies, lists or labels a particular piece of equipment, or determines if to be safe, special actions, involving the authority having jurisdiction (AHJ), are required to assure that the equipment complies with regulations. Such equipment would include custom-made one-of-a-kind equipment, equipment made "in-house" for research or other special purposes and equipment manufactured outside of the United States. This paper gives guidance towards ensuring that electrical equipment meets the safety intention of present-day regulations, codes and standards.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Attributing harmonics in private power production Neutral grounding-nothing new-tral about it [power network protection] Hybrid high-speed DC circuit breaker using charge-storage diode Effects of voltage harmonics on the electrical and mechanical performance of a three-phase induction motor Short-circuit currents to perform a protective device coordination study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1