{"title":"HIF分析采用离散小波变换","authors":"V. Torres, H. Ruiz-Paredes, R. Venegas, Z. Ramírez, G. J. P. Torres","doi":"10.1109/ROPEC.2017.8261678","DOIUrl":null,"url":null,"abstract":"A high-impedance fault (HIF) is generated when an overhead power line physically breaks and falls to the ground or when makes unwanted contact with any object to ground which restricts the flow of current. Such kind of fault are difficult to detect and locate in electric distribution systems because of the small currents magnitudes involved which cannot be detected by conventional overcurrent protection. Furthermore, an arcing often accompanies high-impedance faults that can result in fire hazard, damage to electrical equipment, or even worst, a risk to human life. For these reasons the high impedance faults phenomenon has been the subject of intense research. In this paper an analysis HIF field test using the discrete wavelet transform (DWT) is presented, the proposed analysis is a step forward in the HIFs detection and localization in electric distribution systems.","PeriodicalId":260469,"journal":{"name":"2017 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"HIF analysis using discrete wavelet transform\",\"authors\":\"V. Torres, H. Ruiz-Paredes, R. Venegas, Z. Ramírez, G. J. P. Torres\",\"doi\":\"10.1109/ROPEC.2017.8261678\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A high-impedance fault (HIF) is generated when an overhead power line physically breaks and falls to the ground or when makes unwanted contact with any object to ground which restricts the flow of current. Such kind of fault are difficult to detect and locate in electric distribution systems because of the small currents magnitudes involved which cannot be detected by conventional overcurrent protection. Furthermore, an arcing often accompanies high-impedance faults that can result in fire hazard, damage to electrical equipment, or even worst, a risk to human life. For these reasons the high impedance faults phenomenon has been the subject of intense research. In this paper an analysis HIF field test using the discrete wavelet transform (DWT) is presented, the proposed analysis is a step forward in the HIFs detection and localization in electric distribution systems.\",\"PeriodicalId\":260469,\"journal\":{\"name\":\"2017 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC)\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ROPEC.2017.8261678\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ROPEC.2017.8261678","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

高阻抗故障(HIF)是当架空电力线物理断线并落到地面或与任何限制电流流动的物体产生不必要的接触时产生的。这类故障在配电系统中检测和定位困难,因为涉及的电流量小,而传统的过流保护无法检测到。此外,电弧通常伴随着高阻抗故障,这可能导致火灾危险,损坏电气设备,甚至最糟糕的是,对人的生命构成威胁。由于这些原因,高阻抗故障现象一直是人们研究的热点。本文提出了一种基于离散小波变换(DWT)的HIF现场测试分析方法,该方法在配电系统HIF检测与定位方面迈出了一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
HIF analysis using discrete wavelet transform
A high-impedance fault (HIF) is generated when an overhead power line physically breaks and falls to the ground or when makes unwanted contact with any object to ground which restricts the flow of current. Such kind of fault are difficult to detect and locate in electric distribution systems because of the small currents magnitudes involved which cannot be detected by conventional overcurrent protection. Furthermore, an arcing often accompanies high-impedance faults that can result in fire hazard, damage to electrical equipment, or even worst, a risk to human life. For these reasons the high impedance faults phenomenon has been the subject of intense research. In this paper an analysis HIF field test using the discrete wavelet transform (DWT) is presented, the proposed analysis is a step forward in the HIFs detection and localization in electric distribution systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The teaching-learning of Graph Theory with the support of Learn Graph-Ware software Efficiency based comparative analysis of selected classical MPPT methods YOCASTA: A ludic-interactive system to support the detection of anxiety and lack of concentration in children with disabilities Design and analysis of performance of a forward converter with winding tertiary Sags and swells compensation and power factor correction using a dynamic voltage restorer in distribution systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1