{"title":"一种干电极移动脑电图系统","authors":"G. Gargiulo, P. Bifulco, R.A. Calvo, M. Cesarelli, C. Jin, A. V. Schaik","doi":"10.1109/BIOCAS.2008.4696927","DOIUrl":null,"url":null,"abstract":"A new EEG recording device demonstrating an ultra-high input impedance is presented. Dry electrodes made of conductive rubber were employed for this study with careful shielding of the electrodes and cables. The device has a small form factor, so it is wearable, and has continuous Bluetooth connectivity. Tests were performed to assess features of the proposed device and to compare it with standard clinical devices. Simultaneous EEG recordings were measured from adjacent sites on the scalp using the new EEG device with dry electrodes and a reference EEG device with standard electrodes. The gain and bandwidth settings for the two devices were set similarly. Traditional closing eyes alpha-wave replacement and mu-rhythm were compared in both the time and frequency domains. Results from eight subjects show a high correlation coefficient (0.83 on average) between recordings of contiguous dry and standard electrodes. We conclude that the performance of the new device is comparable with standard EEG recording equipment, but offers a shorter set-up time, the possibility of long-term recording, and a wireless connection - all of which are advantages valuable in the field of brain computer interfaces and neurofeedback.","PeriodicalId":415200,"journal":{"name":"2008 IEEE Biomedical Circuits and Systems Conference","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"100","resultStr":"{\"title\":\"A mobile EEG system with dry electrodes\",\"authors\":\"G. Gargiulo, P. Bifulco, R.A. Calvo, M. Cesarelli, C. Jin, A. V. Schaik\",\"doi\":\"10.1109/BIOCAS.2008.4696927\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new EEG recording device demonstrating an ultra-high input impedance is presented. Dry electrodes made of conductive rubber were employed for this study with careful shielding of the electrodes and cables. The device has a small form factor, so it is wearable, and has continuous Bluetooth connectivity. Tests were performed to assess features of the proposed device and to compare it with standard clinical devices. Simultaneous EEG recordings were measured from adjacent sites on the scalp using the new EEG device with dry electrodes and a reference EEG device with standard electrodes. The gain and bandwidth settings for the two devices were set similarly. Traditional closing eyes alpha-wave replacement and mu-rhythm were compared in both the time and frequency domains. Results from eight subjects show a high correlation coefficient (0.83 on average) between recordings of contiguous dry and standard electrodes. We conclude that the performance of the new device is comparable with standard EEG recording equipment, but offers a shorter set-up time, the possibility of long-term recording, and a wireless connection - all of which are advantages valuable in the field of brain computer interfaces and neurofeedback.\",\"PeriodicalId\":415200,\"journal\":{\"name\":\"2008 IEEE Biomedical Circuits and Systems Conference\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"100\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 IEEE Biomedical Circuits and Systems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2008.4696927\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE Biomedical Circuits and Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2008.4696927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 100

摘要

介绍了一种具有超高输入阻抗的新型脑电图记录装置。本研究采用导电橡胶制成的干电极,并仔细屏蔽电极和电缆。这款设备外形小巧,适合佩戴,并具有连续的蓝牙连接功能。进行测试以评估所建议装置的特征,并将其与标准临床装置进行比较。使用新型干电极脑电图仪和标准电极参考脑电图仪同时测量头皮相邻部位的脑电图记录。两个器件的增益和带宽设置类似。在时域和频域上比较了传统闭眼的α波替代和mu节律。8名受试者的结果显示,连续干电极和标准电极记录之间的相关系数很高(平均0.83)。我们得出的结论是,新设备的性能与标准脑电图记录设备相当,但提供了更短的设置时间,长期记录的可能性,以及无线连接-所有这些都是在脑机接口和神经反馈领域有价值的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A mobile EEG system with dry electrodes
A new EEG recording device demonstrating an ultra-high input impedance is presented. Dry electrodes made of conductive rubber were employed for this study with careful shielding of the electrodes and cables. The device has a small form factor, so it is wearable, and has continuous Bluetooth connectivity. Tests were performed to assess features of the proposed device and to compare it with standard clinical devices. Simultaneous EEG recordings were measured from adjacent sites on the scalp using the new EEG device with dry electrodes and a reference EEG device with standard electrodes. The gain and bandwidth settings for the two devices were set similarly. Traditional closing eyes alpha-wave replacement and mu-rhythm were compared in both the time and frequency domains. Results from eight subjects show a high correlation coefficient (0.83 on average) between recordings of contiguous dry and standard electrodes. We conclude that the performance of the new device is comparable with standard EEG recording equipment, but offers a shorter set-up time, the possibility of long-term recording, and a wireless connection - all of which are advantages valuable in the field of brain computer interfaces and neurofeedback.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A wireless neural interface for chronic recording Development of novel SAW devices in CMOS technology for biosensor applications An efficient wireless power link for high voltage retinal implant FPGA implementation of 4-channel ICA for on-line EEG signal separation Pressure detection and wireless interface for patient bed
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1