Mingyu Zhou, Yuzhen Zhou, Q. Zhuang, Zhengyi Han, X. Lei
{"title":"开发试验中硅橡胶绝缘超高压直流电缆附件局部放电的测量","authors":"Mingyu Zhou, Yuzhen Zhou, Q. Zhuang, Zhengyi Han, X. Lei","doi":"10.1109/POWERCON.2018.8601835","DOIUrl":null,"url":null,"abstract":"In the booming market of high voltage DC cables, the progress of developing accessories become a main bottleneck. In this paper, we firstly introduce our DC cable accessories insulated with silicone rubber, a material currently applied much more frequently in AC than in DC. Then, our experience on testing the 320 kV system, as well as our preliminary experience on diagnosing the 500 kV system in factory will be introduced and discussed. Based on the discussion, we recommend to perform partial discharge tests before load cycle tests to control the quality of installation.","PeriodicalId":260947,"journal":{"name":"2018 International Conference on Power System Technology (POWERCON)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measuring Partial Discharge on EHV DC Cable Accessories Insulated with Silicone Rubber in Development Tests\",\"authors\":\"Mingyu Zhou, Yuzhen Zhou, Q. Zhuang, Zhengyi Han, X. Lei\",\"doi\":\"10.1109/POWERCON.2018.8601835\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the booming market of high voltage DC cables, the progress of developing accessories become a main bottleneck. In this paper, we firstly introduce our DC cable accessories insulated with silicone rubber, a material currently applied much more frequently in AC than in DC. Then, our experience on testing the 320 kV system, as well as our preliminary experience on diagnosing the 500 kV system in factory will be introduced and discussed. Based on the discussion, we recommend to perform partial discharge tests before load cycle tests to control the quality of installation.\",\"PeriodicalId\":260947,\"journal\":{\"name\":\"2018 International Conference on Power System Technology (POWERCON)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Power System Technology (POWERCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERCON.2018.8601835\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Power System Technology (POWERCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERCON.2018.8601835","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Measuring Partial Discharge on EHV DC Cable Accessories Insulated with Silicone Rubber in Development Tests
In the booming market of high voltage DC cables, the progress of developing accessories become a main bottleneck. In this paper, we firstly introduce our DC cable accessories insulated with silicone rubber, a material currently applied much more frequently in AC than in DC. Then, our experience on testing the 320 kV system, as well as our preliminary experience on diagnosing the 500 kV system in factory will be introduced and discussed. Based on the discussion, we recommend to perform partial discharge tests before load cycle tests to control the quality of installation.