{"title":"一种基于导频保护通信通道的变电站后备保护","authors":"Xiangping Kong, Zhe Zhang, Fei Wang, Xianggen Yin","doi":"10.1109/PESMG.2013.6672207","DOIUrl":null,"url":null,"abstract":"In order to solve the problems of traditional distance protection when it is used as back-up protection, a novel substation back-up protection scheme based on communication channel of pilot protection is proposed. According to comprehensive decision-making result of action states of protections in local substation and fault detection information transmitted by adjacent substations, the functions of proposed substation back-up protection are realized. Finally, a simulation model of IEEE 10-generator-39-node system is built in PSCAD/EMTDC to test the performance of proposed substation back-up protection. Simulation results show the proposed substation back-up protection has excellent performance even in condition of fail-to trip of primary protection, DC power supply failure and heavy flow transfer. The proposed substation back-up protection can quicken the tripping of back-up protection and improve sensitivity.","PeriodicalId":433870,"journal":{"name":"2013 IEEE Power & Energy Society General Meeting","volume":"103 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A novel substation back-up protection based on communication channel of pilot protection\",\"authors\":\"Xiangping Kong, Zhe Zhang, Fei Wang, Xianggen Yin\",\"doi\":\"10.1109/PESMG.2013.6672207\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to solve the problems of traditional distance protection when it is used as back-up protection, a novel substation back-up protection scheme based on communication channel of pilot protection is proposed. According to comprehensive decision-making result of action states of protections in local substation and fault detection information transmitted by adjacent substations, the functions of proposed substation back-up protection are realized. Finally, a simulation model of IEEE 10-generator-39-node system is built in PSCAD/EMTDC to test the performance of proposed substation back-up protection. Simulation results show the proposed substation back-up protection has excellent performance even in condition of fail-to trip of primary protection, DC power supply failure and heavy flow transfer. The proposed substation back-up protection can quicken the tripping of back-up protection and improve sensitivity.\",\"PeriodicalId\":433870,\"journal\":{\"name\":\"2013 IEEE Power & Energy Society General Meeting\",\"volume\":\"103 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-07-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Power & Energy Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESMG.2013.6672207\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Power & Energy Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESMG.2013.6672207","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A novel substation back-up protection based on communication channel of pilot protection
In order to solve the problems of traditional distance protection when it is used as back-up protection, a novel substation back-up protection scheme based on communication channel of pilot protection is proposed. According to comprehensive decision-making result of action states of protections in local substation and fault detection information transmitted by adjacent substations, the functions of proposed substation back-up protection are realized. Finally, a simulation model of IEEE 10-generator-39-node system is built in PSCAD/EMTDC to test the performance of proposed substation back-up protection. Simulation results show the proposed substation back-up protection has excellent performance even in condition of fail-to trip of primary protection, DC power supply failure and heavy flow transfer. The proposed substation back-up protection can quicken the tripping of back-up protection and improve sensitivity.